Loading...
Sandy Lk Cross L3-CS 870323GINN, INC. CONSULTING ENGINEERS TO: Shohre Daneshmand, Civil Engineer Attn: Taryon Bowman, Senior Planning Technician FROM: Ginn, Inc. DATE: March 23, 1987 SUBJECT: Preliminary Plat Sandy Lake Crossing SW Corner Sandy Lake Road/Denton Tap Road Upon completing review of the above referenced project, we offer the following comments: 1. Preliminary plat needs additional information provided as per the Subdivision Ordinance. Name of subdivision Survey description Signature block for P&Z/Council approval 2. Maximum fire hydrant spacing should be 300 feet. Also please indicate water/sewer services for lots 1 thru 5. Indicate water/sewer demands. 3. Provide right-of-way dedication along Sandy Lake Road for 110' width future right-of-way and 130' within 300 feet of intersection. 4. Coordinate drive openings across Sandy Lake Road to north and Denton Tap to east with those adjoining owners. 5. Minimum spacing of median openings along Denton Tap shall be 420 feet. 6. Minimum spacing between drives shall be 150 feet. 7. Surrounding zoning on present zoning map indicates "C" Commercial, not "R" Retail. 8. Maximum width on drives shall be 30 feet. 9. Need to identify drainage design proposed so that system can be evaluated. Appears that entire site "sheet" flows to north drives, but no further provisions seem to be made. Please clarify. Drainage of this area is very important. Gabe Favre /ss 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900