Loading...
Grandy's-CS010920 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE NO: S-1193 Grandy's Restaurant P & Z HEARING DATE: September 20, 2001 C.C. HEARING DATE: October 9, 2001 STAFF REP.: Andrea Roy, City Planner LOCATION: At the northwest comer of Denton Tap Road and Fitness Court (formerly North Texas Court) SIZE OFAREA: Approximately 2,714 square-foot restaurant on a portion of approximately 1.39 acres of property. CURRENT ZONING: C (Commercial) REQUEST: C-S.U.P. (Special Use Permit-1193 approval for a restaurant) APPLICANT: Applicant: Engineer: Harry & Kathryn King Hudson Engineering Co. d/b/a KAKI Enterprises, Inc. Billy Hudson, P.E. 3616 Austin Court 358 NW 2nd Street, #4 Flower Mound, TX 75028 Grand Prairie, TX 75090 Phone: 214-513-1520 Phone: 972-262-9383 Fax: 972-691-6396 Fax: 972-262-9384 HISTORY: A preliminary plat for this site, and the remainder of the Denton Tap Development, was approved by City Council on August 12, 1997; however, a final plat for the property was never filed for consideration. TRANSPORTATION: Denton Tap Road is an improved six-lane divided thorouglffare (P6D) contained within a 100'-wide fight-of-way. Page I of 4 Item # 5 SURROUNDING LAND USE & ZONING: North -Town Center West Shopping Center, PD178R-C (Commercial) South - Taco Bell, C-S.U.P 1034 (Commercial-Special Use Permit) East - retail center under construction, TC (Town Center) West- vacant, C (Commercial) COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for neighborhood retail. DISCUSSION: The applicant is requesting Special Use Permit approval for the development of a 2,714 square-foot freestanding Grandy's restaurant with drive-through facility. As proposed, the site will be developed in two phases; Grandy's being Phase I and a future 2,480 square-foot building being Phase II. The proposed Grandy's restaurant will sit toward the northern portion of the site, adjacent to the Town Center West Shopping Center and the future building site is situated on the southern portion of the site, closest to Fitness Court. While the use may be appropriate at this location, this site plan has significant technical issues, as detailed within 14 outstanding issues in the Recommendation section of this report. Staff cannot support this request as submitted. The general issues include the inefficient design of the site, an excessive amount of pavement, an extreme deficiency in landscaping (approximately 3,375 square feet and a number of trees), and numerous inaccuracies and inconsistencies among plan sheets. Specific design issues include: the northern curb turn at Fitness Court and Denton Tap Road does not align, the proposed monument sign is located within the 15' setback area, both northern entryways are excessively wide, and a significant amount of the required information is not provided on the site plan sheet. Additionally, staff is seriously concerned with the manner in which the site is being developed. Again, the use is appropriate; however, this particular site, as designed, is not conducive to the development of two restaurants. It is clear that the type of user for Phase II of this site would likely be similar to that of Grandy's and the reduction in the size of building, limited convenient parking for customers, and the elimination of a drive-through has placed a self-created hardship on this portion of the site that staff cannot support. Further, staff is concerned that the additional required alterations to bring the current plan into compliance will further reduce the Phase II building size and/or feasibility of this portion of the development. To provide a valid comparison, staff reviewed the adjacent Taco Bell site, which contains 50,750 square feet (1.2 acres), only slightly smaller than Page 2 of 4 Item # 5 the subject site (1.4 acres). The primary distinction between Grandy's and the Taco Bell site is that Taco Bell contains only one 2,350 square-foot building, not two buildings, totaling 5,195 square feet. In staff's opinion, the applicant is simply overbuilding the subject site. While the applicant has made improvements to the design of building since the initial submission, there remains significant site design issues which must be addressed prior to staff support of this application. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending DENIAL of the subject application for the following reasons: 1) Proposed Site Plan is lacking the following information: · Existing Zoning · Building height · Proposed lot coverage · Floor area ratio 2) The proposed plan creates a self-inflicted hardship for furore development of Phase II. 3) The Parking Table on Site Plan Sheet incorrectly indicates the number of required and proposed spaces for each phase of development. 4) Entry curb radii on the north side of the intersection of Denton Tap and Fitness Court does not align. 5) The proposed monument sign is placed within the 15' required setback area. 6) Excessive notes showing curve radii need to be removed from plan. 7) The widths of the two northern entrances need to be significantly reduced to not exceed the width of those on the adjacent property to the north. 8) Signage detail needs to indicate the color of the lettering. 9) No light source for monument sign is shown. 10) Staff needs clarification of the reason for constructing the monument sign with approximately 1' of buried brick detail. 11). The plan continues to indicate red illuminated letters on the attached signage. According to the submitted colored renderings, the proposed signage is now white. 12) Incorrect notes on building elevations which indicate that proposed signage is "mounted on standing seam metal roof'; this is not as it appears on the drawings; roof signs are not permitted. 13) There are no dimensions on signage shown on the building elevations. 14) There continue to be inconsistencies between submitted architectural elevations and color renderings. 15) There is an excessive amount of notations regarding underground utility lines on site plan and landscape plan. Page 3 of 4 Item # 5 16) The proposed Landscape Plan continues to be deficient in the following areas_' · Perimeter landscaping -- one tree is not provided every 50' linear feet along Denton Tap. Five trees are required and only two are proposed. · Non-vehicular landscaping -- staff calculations indicate that there is a deficiency of approximately 3,375 square feet. · Non-vehicular landscaping -- four trees are required and only two are proposed. · Interior landscaping -- deficient by a minimum of four trees. · Interior landscaping -- deficient with regard to the provision of a tree within a minimum 150 square-foot landscape island at the end of each row. ALTERNATIVES: 1) Recommend approval of the request. 2) Recommend disapproval of the request 3) Recommend modification of the request 4) Hold Special Use Permit under advisement ATTACHMENTS: 1) Engineering comments 2) Site Plan 3) Monument Sign and Details 4) Landscape Plan 5) Floor Plan 6) Elevations Page 4 of 4 Item # 5 DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: $-1193, Grandy's Restaurant, zoning change request fi.om C (Commercial) to C-S.U.P (Commercial, Special Use Permit-1193), to allow the operation of' an approximately 2,714 square-foot restaurant on a portion of' approximately 1.39 acres of' property located at the northwest comer o£ Denton Tap Road and Fitness Court (North Texas Court), at the request o£I-Iudson Engineering. DRC DA TE: ~lugust 30, 2001 and September 6, 2001 CONTACT: Kenneth M. Griffin, P.E., Director of Engineering (972-304-3679) COM3'IENT STATUS: r~r:,rr r~,rrnTa r:,v ,"'FINAL r~r~rrcr~n 1. Drainage information will be evaluated during plan review process. 2. Fire line and fire hydrants are private. Need to provide meter and vault at tie-in to existing 8" water line. Meter and vaults need to be in an easement. Utility plans will be evaluated during plan review process.