ST9302-LR010913 REPORT OF FIELD
COMPACTION TESTS
ALPHA TESTING, INC.
2209 Wisconsin St.. Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR CITY OF COPPELL DATE 09/13/01
COPPELL, TEXAS
PROJECT SANDY LAKE ROAD PROJ. NO. ST 93 OUR REPORT NO. 98881-218
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OP~MUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
662 09/13/01 FG 16L 14.0 113.5 15.9 113 100 1-A
663 09/13/01 FG 16L 14.0 113.5 16.6 113 100 1-A
TEST LOCATION:
662 PAVING - 18' EAST AND 10' SOUTH FROM NORTHEAST CORNER OF DENTONTAP & SANDY LAKE
663 PAVING - 50' EAST AND 15' SOUTH FROM NORTHEAST CORNER OF DENTONTAP & SANDY LAKE
1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATION,SV~
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~sp ed
3. LIME STABIUZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENT TREATED D RETEST ~j[L7
Our test res~Jlts & reports are i'or the exclusNe use of the Client (and their deS~lnated reciPients on tile in our office) and shall not be reproduced and/or d~buted ~
of our name & test results must receive our written approval. Test result', & reports apply only to the samples tested and/or observed, and are not indicative of the qu~ ~e ns.
Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting