SC-CFBISD Riverchase-LR000419FUGRO SOUTH, INC. 2880 Vlrgo Lane; Dallas, Texas 75229 Ph (972)484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Carrollton-Farmers Branch lSD, c/o DaI-Mac Const. Riverchase Elementary School, Coppell, Texas REPORT DATE: April 19, 2000 PROJECT NO: 0791-2184 SAMPLE DATE: March 20, 2000 J CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C.1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Dal Mac 474862 72 62 11:57 am 12:25 pm Sunny/windy CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C-231): WATER ADDED (gal): SLUMP (in.) (ASTM C.143): Stage floor for auditorium Pioneer 27/924 9124 0 5 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) REC 241 7 03/27100 95000 3360 3000/28 days. ... REC 242 28 04/17/00 124000 4390 REC 243 28 04/17/00 122000 4320 REC 244 Hold Fracture mode is (A) unless otherwiSe noted Specifications: Making & ASTM C-31 Testing ASTM C.143, Typesof [~] [~ [~;1 ~" Cudng: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Yancey Bivings FUGRO SOUTH INC. SMH/rm Distr bution: Reviewed By: ~ DaI-Mac Construction - Jason Lillard DaI-Mac Construction - Nate Payne City of Coppell - Larry Davis / City of Coppell - Lee Stone SHW Group - Joe Craddock SHW Group - Terry Hoyle Carrollton - Farmers Branch lSD - Tom Bell