SC-CFBISD Riverchase-LR 991117FUGRO SOUTH, INC. 2880 virgo Lane; Dallas. Texas 75229 Ph (972) 484.8301; Fax (972) 620-7328 CLIENT: PROJECT: COMPRESSIVE STRENGTH OF MORTAR CUBES Carrollton-Farmers Branch lSD, cio DaI-Mac Const. Report Date: November 17, 1999 Riverchase Elementary School, Coppell, Texas Project NO.: 0791-2184 SAMPLE DATE: November9, 1999 Contractor: Method of Test: Sample Location: Time Batched: Results I Remarks: Dal Mac ASTM C- 109 Gymnasium east wall Row 42 to the top 7:20 am Time Sampled: Type S 7:25 am SAMPLE AGE DATE AREA APPLIED COMPRESSIVE REQUIRED NUMBER TESTED LOAD STRENGTH STRENGTH (days) (sq. in.) (lbs.) (psi) (psi/days) REC 169 7 11116/99 4.0 6740 1685 1800/28 REC 170 7 11/16/99 4.0 6850 1710 REC 171 7 11/16/99 4.0 6915 1730 REC 172 28 12/07/99 4.0 REC 173 28 12107/99 4.0 REC 174 28 12/07/99 4.0 Remarks: Temperature: Mortar 66° Temperature: Ambient 68° William Granger Technician SMH/rm Distribution: DaI-Mac Construction - Jason Lillard City of Coppeil - Larry Davis SHW Group - Joe Craddock Carrollton - Farmers Branch lSD - Tom Bell FUGRO SOUTH INC. Reviewed By: ~ .... DaI-Mac Construction -Nate Payne City of Coppell - Lee Stone SHW Group - Terry Hoyle FUGRO SOUTH, INC. CLIENT: PROJECT: 2880 Virgo Lane; Ph (972) 484-8301; COMPRESSIVE STRENGTH OF MORTAR CUBES Carrollton-Farmers Branch lSD, c/o DaI-Mac Const. Riverchase Elementary School, Coppell, Texas Dallas, Texas 75229 Fax (972) 620-7328 Report Date: November 17, 1999 Project No.: 0791-2184 SAMPLE DATE: November 8, 1999 Contractor: Method of Test: Sample Location: Time Batched: Results I Remarks: Dal Mac ASTM C-109 Gymnasium east wall row 37 up 11:35 am Time Sampled: Type S 11:41 am SAMPLE AGE DATE AREA 'APPLIED COMPRESSIVE REQUIRED NUMBER TESTED LOAD STRENGTH STRENGTH (days) (sq. in.) (lbs.) (psi) (psi/da)ts) REC 163 7 11/15/99 4.0 8550 2140 1800/28 REC 164 7 11/15/99 4.0 8375 2090 REC 165 7 11/15/99 4.0 8420 2110 REC 166 28 12/06/99 4.0 REC 167 28 1 ?-J06/99 4.0 REC 168 28 12/06/99 4.0 Remarks: Temperature: Mortar 80° Temperature: Ambient 84° William Granger Technician SMH/rm Distribution: DaI-Mac Construction - Jason Lillard City of Coppell - Larry Davis SHW Group - Joe Craddock Carrollton - Farmers Branch lSD -Tom Bell FUGRO SOUTH INC. Reviewed By: ~ DaI-Mac Construction - Nate Payne City of Coppell - Lee Stone SHW Group - Terry Hoyle FUGRO SOUTH, INC. 2880 virgo Lane; Dallas, Texas 75229 Ph (972)484-8301; Fax (972) 620-7328 CLIENT: PROJECT: COMPRESSIVE STRENGTH OF MORTAR CUBES Carrollton-Farmers Branch lSD, c/o DaI-Mac Const. Report Date: November 17, 1999 Riverchase Elementary School, Coppell, Texas Project No.: 0791-2184 SAMPLE DATE: November 5, 1999 Contractor: Method of Test: Sample Location: Time Batched: Results I Remarks: Dai Mac ASTM C-109 South side of gymnasium 18th row 11:05 am Time Sampled: Type S 11:10 am 'SAMPLE AGE DATE AREA APPLIED coMPRESSIVE REQUIRED NUMBER TESTED LOAD STRENGTH STRENGTH (days) (sq. in.) (lbs.) (psi) (psi/days) REC 157 7 11/12/99 4.0 6650 1660 1800/28 REC 158 7 11/1 2/99 4.0 6715 1680 REC 159 7 11/1 2/99 4.0 6850 1710 REC 160 28 12/03/99 4.0 REC 161 28 12/03/99 4.0 REC 162 28 12/03/99 4.0 Remarks: Temperature: Mortar 76° Temperature: Ambient 74° William Granger Technician FUGRO SOUTH INC. SMH/rrn Distribution: DaI-Mac Construction - Jason Lillard City of Coppetl - Larry Davis SHW Group - Joe Craddock Carrollton - Farmers Branch lSD - Tom Bell Reviewed By: ~ DaI-Mac Construction - Nate Payne City of Coppell - Lee Stone SHW Group - Terry Hoyle FUGRO SOUTH, INC. CLIENT: PROJECT: 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF MORTAR CUBES Carrollton-Farmers Branch lSD, c/o DaI-Mac Const. Report Date: November 17, 1999 Riverchase Elementary School, Coppell, Texas Project No.: 0791-2184 SAMPLE DATE: November 4, 1999 Contractor: Method of Test: Sample Location: Time Batched: Results I Remarks: Dal Mac ASTM C-109 East wall of gymnasium, 9th and 10th coarses 12:05 Time Sampled: Type S 12:15 SAMPLE AGE DATE AREA APPLIED COMPRESSIVE REQUIRED NUMBER TESTED LOAD STRENGTH STRENGTH (days) (sq. in.) (lbs.) (psi) (psi/days) REC 151 7 11/11/99 4.0 11060 2770 1800/28 REC 152 7 11/11/99 4.0 11035 2760 REC 153 7 11/11/99 4.0 11000 2750 REC 154 28 12/02/99 4.0 REC 155 28 12/02/99 4.0 REC 156 28 12/02/99 4.0 Remarks: John Gipson Technician SMH/rm Distribution: DaI-Mac Construction - Jason Lillard City of Coppell - Larry Davis SHW Group - Joe Craddock Carrollton - Farmers Branch lSD - Tom Bell FUGRO SOUTH INC. Reviewed By: ~ DaI-Mac Construction - Nate Payne City of Coppell - Lee Stone SHW Group - Terry Hoyle FUGRO SOUTH, INC. CLIENT: PROJECT: 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF MORTAR CUBES Carrollton-Farmers Branch lSD, c/o DaI-Mac Const. Riverchase Elementary School, Coppell, Texas Report Date: November 17, 1999 Project No.: 0791-2184 SAMPLE DATE: October 19, 1999 Contractor: Method of Test: Sample Location: Time Batched: Results / Remarks: Dal Mac ASTM C-109 North side of gymnasium 30 up all across 11:20 am Time Sampled: Type S 11:30 am SAMPLE AGE DATE AREA APPLIED COMPRESSIVE REQUIRED NUMBER TESTED LOAD STRENGTH STRENGTH (days) (sq. in.) (lbs.) (psi) (psi/days) , REC 79 7 10/26/99 4.0 8750 2188 1800/28 REC 80 7 10/26/99 4.0 8600 2150 REC 81 7 10/26/99 4.0 8570 2143 REC 82 28 11/16/99 4.0 10420 2610 REC 83 28 11/16/99 4.0 10800 2700 REC 84 28 11/16/99 4.0 10560 2640 Remarks: William Granger Technician SMH/rm Distribution: DaI-Mac Construction - Jason Lillard City of Coppell - Larry Davis SHW Group - Joe Craddock Carrollton - Farmers Branch lSD - Tom Bell FUGRO SOUTH INC. Reviewed By: ~ DaI-Mac Construction - Nate Payne City of Coppell - Lee Stone SHW Group - Terry Hoyle FUGRO SOUTH, INC. 2880 virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF GROUT CYLINDERS CLIENT: Carrollton-Farmers Branch lSD, c/o DaI-Mac Const. PROJECT: Riverchase Elementary School, Coppell, Texas Report Date: November 17, 1999 Project No.: 0791-2184 SAMPLE DATE: October 19, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): GROUT TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Dal Mac 74 72 10:20 am 10:30 am Partly cloudy GROUT SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C-231) WATER ADDED: SLUMP (inches) (ASTM C-143) North side of gymnasium 30 up all across GROUT CYLINDER COMPRESSIVE STRENGTH TESTS Standard 3" x 6", 7.07 square Inches CYLINDER AGE DATE TOTAL LOAD COMPRESSIVE REQUIRED COMPRESSIVE NUMBER (days) TESTED (pounds) STRENGTH STRENGTH (psi) (psi) REC 45 7 10/26/99 17090 2417 2500/28 days REC 46 7 10/22/99 17910 2533 REC 47 28 11/16/99 27830 3940 REC 48 28 11/16~99 27350 3870 Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Cudng: REMARKS: Technician: William Granger FUGRO SOUTH, INC. Reviewed By: ~ SMH/rm Distribution: DaI-Mac Construction - Jason Lillard City of Coppell - Larry Davis SHW Group - Joe Craddock Carrollton - Farmers Branch lSD - Tom Bell DaI-Mac Construction - Nate Payne City of Coppell - Lee Stone SHW Group - Terry Hoyle