Loading...
SC-CFBISD Riverchase-LR 991116FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 STRUCTURAL STEEL INSPECTION REPORT CLIENT: PROJECT: REPORT NO: Carrollton - Farmers Branch lSD c/o DaI-Mac Construction Riverchase Elementary School, Coppell, Texas 3 DATE: November 16, 1999 PROJECT NO: 0791-2184 PAGE I Owner: Architect: Engineer: Contractor: Fabricator: Carrollton - Farmers Branch SHW Group, Inc. SHW Group, Inc. DaI-Mac Construction Location of Project: Coppell, Texas Inspection Performed At: Job Site X Fabrication Shop DESCR#rrtON OF INSPECTION: Structural Steel Irtspectlon } Vllual In~pection of Welds on {Str,I Steel - Metal Deck Units~ or Ultrasonic Testing or Magnetic Particle Inspection of Welds and In~pection of Bolted Connections for compliance to Project specifications, Contract Documents, Drawings, and Governing Codee } AWS, AISC, ASTM, SJI, ASNT, ANSI. See attached Field Reaorts for S~eciflc Items Ins~ected or Tested and Tvoe of Insesction or Testina n®rformed Location of Inspection: See attached Field reports for Specific Areas Inspected or Tested. Results of Inspection: Project Complete Project Incomplete Fabrication Is: Erection Is: X In Compliance X Non Compliance Note: Workmanship type deviafiort$ noted dudng Inspection, which are being corrected at time of Inspection, are not being listed on Report. NOTE: Inspection was performed to vedfy compliance to Project specifications, Contract Documents. Drawings, and Governing Codes} AWS. AISC, ASTM. SJL, ASNT, ANSI Inspected By: Doug Post, AWS/Certified Welding Inspector. ASNT/Certifled Level 2 (UT, MT) Distribution: DaI-Mac Construction - Jason Lillard DaI-Mac Construction - Nate Payne City of Coppell - Larry Davis / City of Coppell - Lee Stone SHW Group - Joe Craddock SHW Group - Terry Hoyle Carrollton - Farmers Branch lSD - Tom Bell Doug Post STR-1 FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 FIELD ERECTION - MEMBERS INSPECTED or TESTED PROJECT: .--~,u~_C~'A,-,,? ~'lc, r~, ~c~ PROJECm~lO:~/~,~_,~./,f.~ REPORT NO: .~ . PAGE ..~- OF_'~ Type of Inspection Location I In Compliance I Non Compliance Check size and Projection of Anchor Bolt Check Anchor Bolt Group Check Nuts on Anchor Bolts / Tight Check Erection Procedures Check for Damaged Members Check Welders Qualification Records Check Fit-Up of Welded Connections Visual Quality of Welds on Structural Steel Visual Quality of Welds on Joists / Girders Visual Quality of Welds on Misc Steel Visual Quality of Welds on Pre Cast Connection Visual Quality of Welds on Composite Deck Visual Quality of Welds on Shear Studs Check Size of Welds on Structural Steel / ! Check Size of Welds on Joists / Girders Check Size of Welds on Misc Steel [ Check Size of w~ds on ~re Cast Co..~on Check Size of Welds on Composite/~r'O~f Check Size of Welds on Shear Studs Ultrasonic Testing of Welds Mag Particle Testing of Welds Report hand wdtten at time of inspection by Field Ins )ector V' in box = In compliance Report will be submitted as is and not typed X in box = Non compliance } See Non compliance report Inspected By: Doug Post, AWS/Certified Welding Inspector, ASNT/Certified Level 2 (UT, MT) STR-2 FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 FIELD ERECTION - MEMBERS INSPECTED or TESTED PROJECT: (~L[/~.~-~E.- ~E,,-, , E~c.~=,.~ PROJECT REPORT NO: ~ PAGE ~ OF In Non Type of Inspection Location Compliance Compliance Check Bolt Tightening Procedure Check Connection for Required Size of Bolts Check Connection for Required No. of Bolts Check Bolt Tightness with Torque Wrench Visual Inspection of Tension Control Bolts Bearing Bolted Connections / Snug Tight Check Bolted Connection /Tum of Nut Check Gap on Loaded Indicator Washers Check Size, Length, and No. of Shear Studs Check Gauge of Composite Deck Check Gauge of Roof Deck Check Size Lap Connection on Composite Deck Check Size Lap on Roof Deck ~::~r ,,,~,'~ ~ ~ Check Installation of Bddging on Joists / Girders ~ Check Installation of Expansion Anchors Check Grout Report hand wdtten at time of inspection by Field Inspector Report will 13e submitted as is and not typed ,~ in box = In compliance X in box = Non compliance } See Non compliance report Inspected By: Doug Post, AWSICertified Welding Inspector. ASNTICertified Level 2 (UT, MT) STR*3