Riverview Estates-LR 970822ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas. Texas 75229 (214) 620-8911 REPORT OF CONCRETE COMPRESSION TEST HUFFINES & PARTNERS TESTED FOR:c/O CCM ENGINEERING DALLAS, TEXAS PROJECT: RIVERVIEW ESTATES COPPELL, TEXAS DATE OF ISSUE: OUR REPORT NO.: AUGUST 22, 1997 97224-59 LOCATION OF CONCRETE PLACEMENT FIELD DATA PAVING: STATION 1+50 OF SUNRISE DRIVE DATE PLACED 0 8 / 2 2 / 9 7 TIME 08 .' 30 SLUMP (ASTM C-143) 2 · 5 AIR CONTENT (ASTM C-231 [] OR C-173 [] )5 ° 2 AIR TEMPERATURE 8 5 CONCRETE TEMPERATURE 8 5 DATE RECEIVED 08 / 2 3/9 7 FIELD DATA SUBMFI-I'ED BY ,,T. S. MIX DATA SUBMI'I-rED BY ON-SITE SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 [~R C-1231 [] PLANT DELIVER TICKET NO MIX PROPORTIONS (SSD) CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE ON-SITE N/A N/A N/A N/A N/A N/A N/A COMPRESSION TEST RESULTS (NOMINAL CYUNDER SIZE 6" X 12") (ASTM c-39) LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE NO. CURING TESTED DAYS LOAD STRENGTH, PSI 93 [d~-B 08/29/97 7 77,825 28.27 2,750 94 [,AB 09/19/97 28 28.2? 95 ~ 09/19/97 28 28.2'7 96 LAB HOLD H Specifications 28 3,0 0 0 COMPUDATA-CG01083-34 REMARKS [~ylinders made by ALPHA representative. [] Cylinders made by Architects or Contractor's representative. [~linders picked up by ALPHA oratory, [] Cylinders delivered to ALPHA laboratory, [] Compressions test results comply with applicable specifications. [] Compression test results do not comply with applicable specifications. lly Submitted STING, INC. PAT STEER ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620-8911 REPORT OF CONCRETE COMPRESSION TEST HUFFINES & PARTNERS TESTEDFOR:C/O CCM ENGINEERING DALLAS, TEXAS DATE OF ISSUE: AUGUST 22, 1997 RIVERVIEW ESTATES PROJECT COPPELL, TEXAS 97224-54 OURREPORTNO.: LOCATION OF CONCRETE PLACEMENT FIELD DATA PAVING: STATION 2+75 OF SUNRISE DRIVE DATE PLACED 0 8 / 2 2 / 9 7 TIME 0 7: 15 SLUMP (ASTM C-143) 3 AIR CONTENT (ASTM C-231 [] OR C-173 r-I) 5 AIR TEMPERATURE 8 0 CONCRETE TEMPERATURE 8 0 DATE RECEIVED 0 8 / 2 3 / 9 7 FIELD DATA SUBMITTED BY J. S. MIX DATA SUBMITTED BY ON--S ITE . SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 ~R C-1231 [] PLANT DELIVER TICKET NO MIX PROPORTIONS (SSD) CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE ON--SITE N/A N/A N/A N/A N/A N/A N/A COMPRESSION TEST RESULTS (NOMINAL CYUNDER SIZE 6" X 12") (ASTM C-~9) LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE NO. CURING TESTED DAYS LOAD STRENGTH, PSI 89 LAB ~8/29/97 7 81,787 28.27 2,890 90 LAB 09/19/97 28 28.27 91 LAB 09/19/97 28 28.27 92 LAB HOLD H specificaltons 2 8 3,0 0 0 COMPUDATA-CG01083-34 REMARKS [~inders made by ALPHA representative. [] Cylinders made by Architect's or Contractor's representative, < nders picked up by ALPHA ratory. [] Cylinders delivered to ALPHA laboratory. [] Compressions test results comply with applicable specifications. [] Compression test results do not comply with applicable specifications. Re%oectfully Submitted A~I4~TESTING, INC. PAT STETTNER ALPHA TESTING, I~/"~. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620-8911 REPORT CONCRETE COMPRESSION TEST HUFFINES & PARTNERS TESTEDFOR:C/O CCM ENGINEERING DALLAS, TEXAS DATE OF ISSUE: AUGUST 22, 1997 PROJECT: RIVERVIEW ESTATES COPPELL, TEXAS 97224-59 OURREPORTNO.: LOCATION OF CONCRETE PLACEMENT PAVING: FIELD DATA STATION 1+,50 OF SUNRISE DRIVE DATE PLACED 08/22/9'/ TIME 08 .' 30 SLUMP (ASTM C-143) 2..5 AIR CONTENT (ASTM C-231 [] OR C-173 c]) '5 · 2 AIR TEMPERATURE 8 5 CONCRETE TEMPERATURE 8 '5 DATE RECEIVED 0 8 / 2 3 / 97 FIELD DATA SUBMITTED BY J. S · MIX DATA SUBMITI'ED BY ON--S ZTE SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 {~P~R C-1231 [] PLANT ON-S I TE DEUVER TICKET I~10 N/A MIX PROPORTIONS (SSD) N/A CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") (ASTM C-39) LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE NO. CURING TESTED DAYS LOAD STRENGTH, PSI 93 [~.S 08/29/97 7 77,825 28.27 2,750 94 LAB 09/19/97 28 105,250 28.27 3,720 95 LAB 09/19/97 28 116,500 28.27 4,120 96 LAB HOLD H Specifications 2 8 3 ~, 0 0 0 COMPUDATA-CG01083-34 REMARKS E~'ylinders made by ALPHA representative. [] Cylinders made by Architect's or Contractor's representative. [~lCa~)linders picked up by ALPHA oratory. [] Cylinders delivered to ALPHA laboratory. {~Compressions test results comply with applicable specifications. [] Compression test results do not comply with applicable specifications. Re~l:~lly Submilt~lttl~,.~-- PAT STETTNER