Riverview Estates-LR 970822ALPHA TESTING, INC.
2209 Wisconsin St.
Suite 100
Dallas. Texas 75229
(214) 620-8911
REPORT OF CONCRETE
COMPRESSION TEST
HUFFINES & PARTNERS
TESTED FOR:c/O CCM ENGINEERING
DALLAS, TEXAS
PROJECT:
RIVERVIEW ESTATES
COPPELL, TEXAS
DATE OF ISSUE:
OUR REPORT NO.:
AUGUST 22, 1997
97224-59
LOCATION OF CONCRETE PLACEMENT
FIELD DATA
PAVING: STATION 1+50 OF
SUNRISE DRIVE
DATE PLACED 0 8 / 2 2 / 9 7
TIME 08 .' 30
SLUMP (ASTM C-143) 2 · 5
AIR CONTENT (ASTM C-231 [] OR C-173 [] )5 ° 2
AIR TEMPERATURE 8 5
CONCRETE TEMPERATURE 8 5
DATE RECEIVED 08 / 2 3/9 7
FIELD DATA SUBMFI-I'ED BY ,,T. S.
MIX DATA SUBMI'I-rED BY ON-SITE
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 [~R C-1231 []
PLANT
DELIVER TICKET NO
MIX PROPORTIONS (SSD)
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
ON-SITE
N/A
N/A
N/A
N/A
N/A
N/A
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYUNDER SIZE 6" X 12")
(ASTM c-39)
LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE
NO. CURING TESTED DAYS LOAD STRENGTH, PSI
93 [d~-B 08/29/97 7 77,825 28.27 2,750
94 [,AB 09/19/97 28 28.2?
95 ~ 09/19/97 28 28.2'7
96 LAB HOLD H
Specifications 28 3,0 0 0
COMPUDATA-CG01083-34
REMARKS
[~ylinders made by ALPHA
representative.
[] Cylinders made by Architects
or Contractor's representative.
[~linders picked up by ALPHA
oratory,
[] Cylinders delivered to ALPHA
laboratory,
[] Compressions test results comply with
applicable specifications.
[] Compression test results do not comply
with applicable specifications.
lly Submitted
STING, INC.
PAT STEER
ALPHA TESTING, INC.
2209 Wisconsin St.
Suite 100
Dallas, Texas 75229
(214) 620-8911
REPORT OF CONCRETE
COMPRESSION TEST
HUFFINES & PARTNERS
TESTEDFOR:C/O CCM ENGINEERING
DALLAS, TEXAS
DATE OF ISSUE:
AUGUST 22, 1997
RIVERVIEW ESTATES
PROJECT COPPELL, TEXAS
97224-54
OURREPORTNO.:
LOCATION OF CONCRETE PLACEMENT
FIELD DATA
PAVING: STATION 2+75 OF
SUNRISE DRIVE
DATE PLACED 0 8 / 2 2 / 9 7
TIME 0 7: 15
SLUMP (ASTM C-143) 3
AIR CONTENT (ASTM C-231 [] OR C-173 r-I) 5
AIR TEMPERATURE 8 0
CONCRETE TEMPERATURE 8 0
DATE RECEIVED 0 8 / 2 3 / 9 7
FIELD DATA SUBMITTED BY J. S.
MIX DATA SUBMITTED BY ON--S ITE .
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 ~R C-1231 []
PLANT
DELIVER TICKET NO
MIX PROPORTIONS (SSD)
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
ON--SITE
N/A
N/A
N/A
N/A
N/A
N/A
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYUNDER SIZE 6" X 12")
(ASTM C-~9)
LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE
NO. CURING TESTED DAYS LOAD STRENGTH, PSI
89 LAB ~8/29/97 7 81,787 28.27 2,890
90 LAB 09/19/97 28 28.27
91 LAB 09/19/97 28 28.27
92 LAB HOLD H
specificaltons 2 8 3,0 0 0
COMPUDATA-CG01083-34
REMARKS
[~inders made by ALPHA
representative.
[] Cylinders made by Architect's
or Contractor's representative,
< nders picked up by ALPHA
ratory.
[] Cylinders delivered to ALPHA
laboratory.
[] Compressions test results comply with
applicable specifications.
[] Compression test results do not comply
with applicable specifications.
Re%oectfully Submitted
A~I4~TESTING, INC.
PAT STETTNER
ALPHA TESTING, I~/"~.
2209 Wisconsin St.
Suite 100
Dallas, Texas 75229
(214) 620-8911
REPORT CONCRETE
COMPRESSION TEST
HUFFINES & PARTNERS
TESTEDFOR:C/O CCM ENGINEERING
DALLAS, TEXAS
DATE OF ISSUE:
AUGUST 22, 1997
PROJECT:
RIVERVIEW ESTATES
COPPELL, TEXAS
97224-59
OURREPORTNO.:
LOCATION OF CONCRETE PLACEMENT
PAVING:
FIELD DATA
STATION 1+,50 OF
SUNRISE DRIVE
DATE PLACED 08/22/9'/
TIME 08 .' 30
SLUMP (ASTM C-143) 2..5
AIR CONTENT (ASTM C-231 [] OR C-173 c]) '5 · 2
AIR TEMPERATURE 8 5
CONCRETE TEMPERATURE 8 '5
DATE RECEIVED 0 8 / 2 3 / 97
FIELD DATA SUBMITTED BY J. S ·
MIX DATA SUBMITI'ED BY ON--S ZTE
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 {~P~R C-1231 []
PLANT ON-S I TE
DEUVER TICKET I~10 N/A
MIX PROPORTIONS (SSD) N/A
CEMENT N/A
WATER N/A
FINE AGGREGATE N/A
COARSE AGGREGATE N/A
ADMIXTURE N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12")
(ASTM C-39)
LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE
NO. CURING TESTED DAYS LOAD STRENGTH, PSI
93 [~.S 08/29/97 7 77,825 28.27 2,750
94 LAB 09/19/97 28 105,250 28.27 3,720
95 LAB 09/19/97 28 116,500 28.27 4,120
96 LAB HOLD H
Specifications 2 8 3 ~, 0 0 0
COMPUDATA-CG01083-34
REMARKS
E~'ylinders made by ALPHA
representative.
[] Cylinders made by Architect's
or Contractor's representative.
[~lCa~)linders picked up by ALPHA
oratory.
[] Cylinders delivered to ALPHA
laboratory.
{~Compressions test results comply with
applicable specifications.
[] Compression test results do not comply
with applicable specifications.
Re~l:~lly Submilt~lttl~,.~--
PAT STETTNER