Riverview Estates-LR 970729ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR HUFFINES & PARTNERS DATE 07/29/97
C/O CCH ENGINEERING
PROJECT RIVERVIEW ESTATES OUR REPORTNO. 97224-26
COPPELL, TEXAS
TEST DATA:
TEST DATE ~ SOIL ID OFTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT*
NO. NUMBER % PCF % PCF COMPACTION
17! 07/29 FG-0.5 2 20.5 99.5 21.0 96 97 1-A
172 07/29 FG 2 20.5 99.5 20.6 97 98 1-A
173 07/~ 29 FG-0.5 2 20.5 99.5 22.9 95 96 1-A
174 07/29 FG-1.0 2 ' 20.5 99.5 20.8 96 97 1-A
175 07/29 FG-2.0 2 20.5 99.5 22.0 96 97 1-A
176 07/29 FG 2 20.5 99.5 22.5 95 95 1-A
177 07/29 FG-1.0 2 20.5 99.5 20.9 97 97 1-A
TEST LOCATION:
171 BLOCK A, PAD 91
172 BLOCK A, PAD 92
173 BLOCK A, PAD %3
174 BLOCK A, PAD 98
175 BLOCK A, PAD 99
176 BI.~)CK B, PAD 92
177 BLOCK B, PAD 94
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR HUFFINES & D~[~R~ DATE 07/29/97
C/O CCM ENGINEERING
PROJECT RIVERVIEW ESTATES OUR REPORT NO. 97224-26A
COPPELL, TEXAS
TEST DATA:
TEST DATE ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT COMMENT*
MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION
NO.DEPTH-~"-,,~ NUMBER % PCF % ~CF
178 07/29 FG-1.2 2 20.5 99.5 22.0 96 96 1-A
179 07/29 FG-0.6 2 20.5 99.5 21.7 96 96 1-A
180 07/29 FG-i.§ 2 20.5 99.5 20.9 97 98 1-A
181 07/29 FG-!.5 2 20.5 99.5 22.6 96 97 1-A
182 07/29 FG-2.5 2 20.5 99.5 20.5 97 98 1-A
TEST LOCATION:
178 BLOCK B, PAD ~ 6
179 BLOCK B, PAD # 8
180 BLOCK B, PAD %10
181 BLOCK B, PAD %12
182 BLOCK B, PAD #14
1. FILL '
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~-'~4"I~I;~IUlly OUUIIIIlt~
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST