Riverview Estates-LR 970728ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR HUFFINES & PARTNERS C/O CCM ENGINEERING DATE 07/28/97 PROJECT RIVERVIEW ESTATES COPPELL, TEXAS OUR REPORT NO, 97224-25 TEST DATA: TEST DATE ~ SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT COMMENT* MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION NO. NUMBER % PCF % PCF 159 07/28 FG-1.0 2 20.5 99.5 21.4 97 98 1-A 16o 07/28 FG-2.0 2 20.5 99.5 23.5 94 95 1-A 161 07/28 FG-2.0 2 20.5 99.5 23.2 95 96 1-A 162 07/28 FG-1.5 2 20.5 99.5 22.6 95 95 1-A 163 07/28 FG-1.5 2 20.5 99.5 22.5 96 96 1-A 164 07/28 FG-1.1 2 20.5 99.5 20.9 96 97~ 1-A 165 07/28 FG-1.5 ~ 20.5 99.5 21.8 95 96 1-A LOCATION: 159 BLOCK A, PAD 17 160 BLOCK A, PAD 18 161 BLOCK A, PAD 19 162 BLOCK A, PAD 20 163 BLOCK A, PAD 21 164 BLOCK A, PAD 25 165 BLOCK A, PAD 26 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPORT. OF FIELD COMPACTION TESTS TESTED FOR HUFFINES & PARTNERS DATE 07/28/97 C/O CCM ENGINEERING PROJECT RIVERVIEW ESTATES COPPELL, TEXAS OUR REPORTNO. 97224-25A TEST DATA: TEST DATE ~ SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT COMMENT* MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION NO. NUMBER % PCF % PCF 166 07/28 FG-2.5 2 20.5 99.5 23.1 95 95 1-A 167 07/28 FG-1.5 2 20.5 99.5 21.4 97 97 1-A 168 07/28 FG-1.0 2 20.5 99.5 22.3 95 95 1-A 169 07/28 FG- ..5 2 20.5 99.5 21.1 97 98 1-A 170 07/28 FG 2 20.5 99.5 21.5 95 95 1-A TEST LOCATION: 166 BLOCK A, PAD 27 167 BLOCK A, PAD 27 168 BLOCK A, PAD 28 169 BLOCK C, PAD 2 170 BLOCK C, PAD 4 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS / ~,~,~,,x ~,~.~ C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST ~ '