Riverview Estates-LR 970723ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR HUFFINES & PARTNERS DATE 07/23/97
C/O CCM ENGINEERING
PROJECT RIVERVIEW ESTATES OUR REPORT NO.
COPPELL, TEXAS
97224-23
TEST DATA:
TEST DATE ~V. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
NO. NUMBER % PCF % PCF
154 07/23 FG-1.5 2 20.5 99.5 22.6 94 95 1-A
135 07/23 FG-1.1 2 20.5 99.5 22.1 96 96 1-A
136 07/23 FG-1.5 2 20.5 99.5 20.6 98 98 1-A
137 07/23 FG-0.5 2 20.5 99.5 20.6 97 97 1-A
138 07/23 FG-2.5 2 20.5 99.5 21.2 97 97 1-A
139 07/23 FG-1.5 2 20.5 99,5 20.9 98 98 1-A
140 07/23 FG-1.2 2 20.5 99.5 21.3 97 97 1-A
TEST LOCATION:
134 BLOCK C, PAD 2
135 BLOCK C, PAD 4
136 BLOCK C, PAD 6
137 BLOCK C, PAD 8
138 BLOCK C, PAD 10
139 BLOCK C, PAD 10
140 BLOCK A, PAD 30
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. C.E~I.~ENT TREATED
CG0i083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~Re '
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /_. __ . _ ___..~..._
D. RETEST
ALPHA TESTING, INC.
2209 Wisconsin St,, Suite 100
Dallas, Texas 75229
(972) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTEDFOR HUFFINES & PARTNERS DATE 07/23/97
C/O CCM ENGINEERING
PROJECT RIVERVIEW ESTATES OUR REPORT NO.
COPPELL, TEXAS
97224-23A
TEST DATA:
TEST I DATE SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
NO. NUMBER % PCF % PCF
14! 07/23 FG-2.1 2 20.5 99; 5 22.5 96 96 1-A
142 07/23 FG-2.5 2 20.5 99.5 21.7 95 95 1-A
143 07/23 FG-1.2 2 20.5 99.5 21.9 97 98 1-A
144 07/23 FG-1.0 2 20.5 99.5 21.3 96 97 1-A
145 07/23 FG-2.5 2 20.5 99.5 22.0 96 96 1-A
TEST LOCATION:
141 BLOCK A, PAD 28
142 BLOCK A, PAD 26
143 BLOCK A, PAD 24
144 BLOCK A, PAD 22
145 BLOCK A, PAD 20
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ,,,~pecffully Submitted/.-~
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /