Loading...
Riverview Estates-LR 970723ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR HUFFINES & PARTNERS DATE 07/23/97 C/O CCM ENGINEERING PROJECT RIVERVIEW ESTATES OUR REPORT NO. COPPELL, TEXAS 97224-23 TEST DATA: TEST DATE ~V. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* NO. NUMBER % PCF % PCF 154 07/23 FG-1.5 2 20.5 99.5 22.6 94 95 1-A 135 07/23 FG-1.1 2 20.5 99.5 22.1 96 96 1-A 136 07/23 FG-1.5 2 20.5 99.5 20.6 98 98 1-A 137 07/23 FG-0.5 2 20.5 99.5 20.6 97 97 1-A 138 07/23 FG-2.5 2 20.5 99.5 21.2 97 97 1-A 139 07/23 FG-1.5 2 20.5 99,5 20.9 98 98 1-A 140 07/23 FG-1.2 2 20.5 99.5 21.3 97 97 1-A TEST LOCATION: 134 BLOCK C, PAD 2 135 BLOCK C, PAD 4 136 BLOCK C, PAD 6 137 BLOCK C, PAD 8 138 BLOCK C, PAD 10 139 BLOCK C, PAD 10 140 BLOCK A, PAD 30 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. C.E~I.~ENT TREATED CG0i083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~Re ' C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /_. __ . _ ___..~..._ D. RETEST ALPHA TESTING, INC. 2209 Wisconsin St,, Suite 100 Dallas, Texas 75229 (972) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTEDFOR HUFFINES & PARTNERS DATE 07/23/97 C/O CCM ENGINEERING PROJECT RIVERVIEW ESTATES OUR REPORT NO. COPPELL, TEXAS 97224-23A TEST DATA: TEST I DATE SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* NO. NUMBER % PCF % PCF 14! 07/23 FG-2.1 2 20.5 99; 5 22.5 96 96 1-A 142 07/23 FG-2.5 2 20.5 99.5 21.7 95 95 1-A 143 07/23 FG-1.2 2 20.5 99.5 21.9 97 98 1-A 144 07/23 FG-1.0 2 20.5 99.5 21.3 96 97 1-A 145 07/23 FG-2.5 2 20.5 99.5 22.0 96 96 1-A TEST LOCATION: 141 BLOCK A, PAD 28 142 BLOCK A, PAD 26 143 BLOCK A, PAD 24 144 BLOCK A, PAD 22 145 BLOCK A, PAD 20 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ,,,~pecffully Submitted/.-~ C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /