Loading...
Riverview Estates-LR 970716ALPHA TESTING, INC. 2209 wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 DAILY FIELD REPORT TESTED FOR HUFFINES & PARTNERS C/O CCM ENGINEERING DATE 07/16/97 PROJECT RIVERVlEW ESTATES COPPELL, TEXAS OUR REPORT NO. 97224-20 WEATHER: CLOUDY TEMPERATURE RANGE: ALPHA Representative: 75 J.B. TO: 95 THE ALPHA TECHNICIAN TRAVELED TO THE ABOVE REFERENCED pROJECT AS REQUESTED TO MONITOR ON-GOING WORK AND PERFORM FIELD TESTING AS REQUESTED. SUBGPJ~DE FOR PADS 14 THROUGH 21, BLOCK B WAS OBSERVED TO VERIFY THAT AREAS HAD BEEN PREPARED IN GENERAL ACCORDANCE WITH GEOTECHNICAL RECOMMENDATIONS. A TOTAL OF 14 FIELD DENSITY TESTS WERE PERFORMED ON FILL AND NATUBAL SUBGPJkDE FOR PAD FILL ARF_~%. SEE ATTACHED REPORT FOR RESULTS OF FIELD COMPACTION TESTING. THE SINACOLA REPRESENTATIVE WAS INFORMED OF ALL OBSERVATIONS AND FIELD TEST RESULTS. AT THE COMPLETION OF THE SCHEDULED TESTING THE TECHNICIAN RETURNED TO THE DALLAS OFFICE. CG01083-29 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (9?2) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTEDFOR HUFFINES & PARTNERS DATE 07/16/97 C/O CCM ENGINEERING PROJECT RIVERVIEW ESTATES OUR REPORT NO. COPPELL, TEXAS 97224-20A TEST DATA: TEST I I~ ELEV. SOIL ID OPT,MUM MAXIMUM LAS IN PLACE IN PLACE PERCENT ~J MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* ~NO. DATE DE NUMBER % PCF % PCF COMPACTION 97 07/16 SG 3 22.2 93.8 24.3 92 98 2-A 98 07/16 SG 3 22.2 93,8 23.7 92 98 2-A 99 07/16 SG 3 22.2 93.8 24.4 90 96 2-A lOO 07/16 SG 3 22,2 93.8 23.0, 93 99 2-A lol 07/16 SG 3 22.2 93.8 24.7 92 98 2-A 102 07/16 SG 3 22.2 93.8 23.9 91 97 2-A 103 07/16 FG-1.2 2 20.5 99.5 21.5 94 95 1-A TEST LOCATION: 93 BLOCK B, PAD 11 98 BLOCK B, PAD 13 99 BLOCK B, PAD 15 100 BLOCK B, PAD 17 101 BLOCK B, PAD 19 102 BLOCK A, PAD 21 103 BLOCK A, PAD 2 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS * A. B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS / Respectfully Submi~d C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST ALPHA TESTING, INC. 2209 wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTEDFOR HUFFINES & PARTNERS DATE 07/16/97 C/O CCM ENGINEERING PROJECT RIVERVIEW ESTATES COPPELL, TEXAS OUR REPORT NO, 97224-20B TEST DATA: TEST DATE ~ SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* NO. NUMBER % PCF % PCF 104 07/16 FG-i.7 2 20.5 99.5 21.6 95 95 1-A 105 07/16 FG-2.0 2 20.5 99.5 21.0 95 96 1-A 106 07/16 FG-3.2 2 20.5 99.5 20.8 95 96 1-'A 107 07/16 FG-3.1 2 20.5 99.5 22.0 95 95 1-A 108 07/16 FG-4.0 2 20.5 99.5 20.9 98 98 1-A 109 07/16 FG-2.5 2 20.5 99.5 21.4 96 96 1-A 110 07/16 FG-3.0 2 20.5 99.5 21.6 95 96 1-A TEST LOCATION: 104 BLOCK A, PA/) 4 105 BLOCK A, PAD 6 106 BLOCK A, PAD 8 107 BLOCK A, PAD 10 108 -BLOCK A, PAD 12 109 BLOCK A, PAD 14 110 BLOCK A, PAD 16 1, FILL 2, NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS~ B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST