Riverview Estates-LR 970505ALPHA TESTIN('~NC. 2209 wisconsin St., suite 100 Dallas, Texas 75229 (972) 620-8911 REPO " I' OF FIELD COMPACTION TESTS TESTED FOR HUFFINES & PARTNERS DATE 05/05/97 C/O CCM ENGINEERING PROJECT RIVERVIEW ESTATES OUR REPORT NO. 97224-12 COPPELL, TEXAS TEST DATA: TEST DA~ ~ SOIL ID O~M~ MAXIMUM LAB IN PLACE IN P~CE PERCE~ COMMENT MOIS~RE nY ~NSFFY ~IS~RE DRY DENS~ COMPACTI~ NO. NUMBER % ~F % ~F 67 05/05 FG-3 2 20.5 99.5 21.4 98 99 I-A 68 05/05 FG-i 2 20,5 99.5 21.~ 97 98 1-A 69 05/05 FG-3 2 20.5 99.5 21.2 98 99 1-A 70 05/05 FG-1 2 20.5 99.5 21.1 99 100 1-A 71 05/05 FG-3 2 20.5 99.5 20.8 98 99 1-A 72 05/05 FG-1 2 20,5 99.5 22.1 98 99 1-A 73 05/05 FG-I 2 20.5 99.5 23.4 96 96 1-A TEST LOCATION: 67 WATER LINE BACKFILL - 200' W OF "T" AT INT OF SANDY LAKE RD & RIVERVIEW DR !68 WATER LINE BACKFILL - 200' W OF "T" AT INT OF SANDY LAKE RD & RIVERVIEW DR 69 WATER LINE BACKFILL - 400' W OF "T" AT INT OF SANDY LAKE RD & RIVERVIEW DR 70 WATER LINE BACKFILL - 400' W OF "T" AT INT OF SANDY LAKE RD & RIVERVIEW DR 71 WATER LINE BACKFILL - 600' W OF "T" AT INT OF SANDY LAKE RD & RIVERVIEW DR 72 WATER LINE BACKFILL - 600' W OF "T" AT INT OF SANDY LAKE RD & RIVERVIEW DR 73 STOiRM SEWER BACKFILL - LINE "A" AT STATION ~5+00 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R~,~ep~'13b~'R ' ed C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST ~,,~ ~~~C. ALPHA TESTI ~N~r. INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR HUFFINES & PARTNERS DATE 05/05/97 C/O CCM ENGINEERING PROJECT RIVERVIEW ESTATES OUR REPORTNO. 97224-12A COPPELL, TEXAS TEST DATA: TEST DATE '""-.,,~LEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT COMMENT* MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION NO.DEPTH ~"-,.~ NUMBER % PCF % PCF 74 05/05 FG-1 2 20.5 99.5 22.9 97 98 1-A 75 05/05 FG-3 2 20.5 99.5 22.6 95 96 1-A ;6 05/05 FG-3 2 20.5 99.5 22.7 98 98 1-A 77 05/05 FG-1 2 20.5 99.5 21.3 98 98 1-A TEST LOCATION: '4 STORM SEWER BACKFILL - LINE "A" AT STATION #7+00 '5 STORM SEWER BACKFILL - LINE "A" AT STATION #7+00 '6 STORM SEWER BACKFILL - LINE "A" AT STATION #9+00 '7 STORM SEWER BACKFILL - LINE "A" AT STATION #9+00 1, FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS -" "' He~~ :suDrr~ed C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS