Loading...
Riverview Estates-LR 970416ALPHA TESTIN(~,NC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPORT OF FIELD COMPACTION TESTS HUFFINES & PARTNERS 04/16/97 TESTED FOR C/O CCM ENGINEERING DATE PROJECT RIVERVIEW ESTATES OUR REPORT NO. 97224-8 COPPELL, TEXAS TEST DATA: TEST DATE ~-...~LEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT COMMENT* MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION NO.DEPTH -'---~ NUMBER % PCF % PCF 17 04/i6 FG-3.0 2 20 . 5 99.5 22.4 97 97 1-A 18 04/16 FG-1.0 2 20.5 99.5 23.6 100 100 1-A 19 04/16 FG-3.0 2 20.5 99.5 21.5 101 102 1-A 20 04/16 FG-1.0 2 20.5 99.5 22.9 96 97 1-A 21 04/16 FG-3.0 2 20.5 99.5 23.9 96 96 1-A 22 04/16 FG-1.0 2 20.5 99.5 24.3 98 98 1-A 23 04/16 FG-3.0 2 20.5 99.5 22.5 99 100 1-A TEST LOCATION: 17 SANITARY SEWER - LINE '~B" AT STATION # 5+00 18 SANITARY SEWER - LINE "B" AT STATION # 5+00 19 SANITARY SEWER - LINE "B" AT STATION # 8+00 20 SANITARY SEWER - LINE "B" AT STATION # 8+00 21 SANITARY SEWER - LINE "B" AT STATION #11+00 22 SANITARY SEWER - LINE '~B" AT STATION #t1+00 23 SANITARY SEWER - LINE "B" AT STATION #12+75 1. FILL 2, NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CGO 1083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATION~-~'"'"'----'~ B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS / Respectf~,l,l~~ C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS TING, INC. D. RETEST Pa ALPHA TESTIN~NC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPO ' T OF FIELD COMPACTION TESTS HUFFINES & PARTNERS 04/16/97 TESTED FOR C/O CCM ENGINEERING DATE PROJECT RIVERVIEW ESTATES OUR REPORT NO. 97224-8A COPPELL, TEXAS TEST DATA: TEST DATE ~ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT COMMENT* MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION NO.DEPTH ~ NUMBER % PCF % PCF 24 04/16 FG-1.0 2 20.5 99.5 21.6 99 100 1-A 25 04/16 FG-3.0 2 20.5 99.5 23.6 96 96 1-A 26 04/16 FG-1 . 0 2 20.5 99.5 24.3 95 95 1-A 27 04/16 FG-3.0 2 20.5 99.5 22.4 98 99 1-A 28 04/16 FG-1.0 2 20.5 99.5 21.0 101 101 1-A TEST LOCATION: 24 SANITi~LRY SEWER - LINE ~B" AT STATION #12+75 25 SANITARY SEWER - LINE ~C" AT STATION # 1+00 26 SANITARY SEWER - LINE ~C" AT STATION ~ 1+00 27 SAiqITARY SEWER - LINE "D" AT STATION ~ 1+00 28 SANITARY SEWER - LINE "D" AT STATION # 1+00 B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Pat ~tettne~G' INC, 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18