SC-Coppell ABA-LR001010QRO FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD, c/o K A Sparks Report Date October 10, 2000 PROJECT Coppell ISD Administration Building, Coppell, Texas Project No .: 0700 -2189 SI PL .#'E: ....... ;�eWx . CONTRACTOR: K. A. Sparks / The Cortez Group TICKET NO.: 3111818 CONCRETE SUPPLIER: LMC AMBIENT TEMP. ( °F): 89 PLANT/TRUCK: 3/1049 CONCRETE TEMP. ( °F) (ASTM c- 1094): 92 MIX ID NUMBER: 38 TIME BATCHED: 8:40 am AIR ( %) (ASTM C-231): STRENGTH TIME SAMPLED: 9:55 am WATER ADDED (gal): 5 WEATHER CONDITION: Sunny SLUMP (in .) (ASTM C -143) : 6 LOCATION OF PLACEMENT: Slab for building addition southeast side, 10 feet north, 8 feet west REMARKS: Technician Yancey Bivings FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: K A Sparks Contractors Inc. — Jim Schooler City of Coppell — Larry Davis ✓� Coppell ISD — Mickey Harper SHW Group — Joe Craddock SHW Group — Mike Elmore N OR M S , R C�MRIi�{E arT�#EGTH 1"ET !i'F � st qa+s tzt TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CAC 31 7 09/12/00 77000 2730 3000/28 days CAC 32 28 10/03/00 108100 3820 CAC 33 28 10 103 /00 106000 3750 CAC 34 Hold node is (A) unless otherwise noted Specifications: Ma ASTM C-31 ASTM C M F To racture ® Cu o ASTM C-39 rer A BE C D REMARKS: Technician Yancey Bivings FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: K A Sparks Contractors Inc. — Jim Schooler City of Coppell — Larry Davis ✓� Coppell ISD — Mickey Harper SHW Group — Joe Craddock SHW Group — Mike Elmore