Loading...
SC-Coppell ABA-LR000908FUGRO SOUTH, INC. r a 2880 Virgo Lane; Dallas, Texas 752 Ph (972) 484 -8301; Fax (972) 620 -7: COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD, c/o K A Sparks Report Date: September 8, 2000 PROJECT: Coppell ISD Administration Building, Coppell, Texas Project No.: 0700 -2189 SAMPLE DATE: August 10, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME .SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Cortez Group 7090994 CONCRETE SUPPLIER: Lattimore 100 PLANT/TRUCK: 7/1092 92 MIX ID NUMBER: SPECIFIED COMPRESSIVE 2:44 AIR (%) (ASTM C -231) : DATE 3:30 WATER ADDED (gal): 10 Clear SLUMP (in.) (ASTM C -143) : 5 Piers: N.1 -3, E4 -9, S17, sampled at N -1 (psi) CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CAC 1 7 08/17/00 75700 2680 3000/28 days CAC 2 28 09/07/00 102700 3630 CAC 3 28 09/07/00 104200 3690 CAC 4 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, I Types of Curing: Methods: ASTM C -39 Fracture: A® B® C D REMARKS: Technician: Steven Campbell FUGRO SOUTH INC. Reviewed By: SMH /rm Distribution: K A Sparks Contractors Inc. — Jim Schooler City of Coppell — Larry Davis Coppell ISD — Mickey Harper SHW Group — Joe Craddock SHW Group — Mike Elmore FUGRO SOUTH, INC. ,.N IIQi R 2880 Virgo Lane; Dallas, Texas 75. Ph (972) 484 -8301; Fax (972) 620-7: COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD, c/o Dal — Mac Construction Co. Report Date: September 8, 2000 PROJECT: Coppell High School, Tennis Court/Parking Lot Project No.: 0791 -2208 Coppell, Texas SAMPLE DATE: August 4, 2000 1 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Dal Mac Construction / The Cortez Group 7090629 CONCRETE SUPPLIER: Lattimore 78 PLANT/TRUCK: 7/1040 88 MIX ID NUMBER: 15145 6:15 am AIR ( %) (ASTM C -231) : 6.9 7:00 am WATER ADDED (gal): 0 Clear SLUMP (in.) (ASTM C -143) : 8 North parking lot west of football field, and next two tennis courts CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CHC 1342 7 08111/00 68400 2420 3000/28 days CHC 1343 28 09/01 /00 86000 3040 CHC 1344 28 09/01/00 87100 3080 CHC 1345 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C -143, C-39 Types of Fracture: A ® Curing: Methods: ASTM BE CH D REMARKS: Technician: Erick Hernandez FUGRO SOUTH INC. Reviewed By: ' SMH /rm Distribution: Dal -Mac Construction — Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell ISD — Mickey Harper SHW Group - Joe Craddock SHW Group — Mike Elmore JRJ Paving —Jeff Williford FUGRO SOUTH. INC. r j - - 2880 Virgo Lane; Dallas, Texas 752: Ph (972) 484 -8301; Fax (972) 620 -73. COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD, c/o Dal — Mac Construction Co. Report Date: September 8, 2000 PROJECT Coppell High School, Tennis Court/Parking Lot Project NO.: 0791 -2208 Coppell, Texas I SAMPLE DATE: August 4, 2000 _1 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Dal Mac Construction / The Cortez Group 14137485 CONCRETE SUPPLIER: Lattimore 86 PLANT/TRUCK: 14/1032 89 MIX ID NUMBER: 15145 8:05 am AIR ( %) (ASTM C -231) : 5.6 9:15 am WATER ADDED (gal): 0 Sunny SLUMP (in.) (ASTM C -143) : 7.50 North parking lot island TESTED REMARKS: Technician: Erick Hernandez FUGRO SOUTH INC. Reviewed By: ' SMH /rm Distribution: Dal -Mac Construction — Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell ISD — Mickey Harper SHW Group - Joe Craddock SHW Group — Mike Elmore JRJ Paving — Jeff Williford CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CHC 1346 7 08/11/00 78900 2790 3000/28 days CHC 1347 28 09/01/00 98200 3470 CHC 1348 28 09/01/00 100400 3550 CHC 1349 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, C Types of Fracture: A® D Curing: Methods: ASTM -39 B C11 REMARKS: Technician: Erick Hernandez FUGRO SOUTH INC. Reviewed By: ' SMH /rm Distribution: Dal -Mac Construction — Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell ISD — Mickey Harper SHW Group - Joe Craddock SHW Group — Mike Elmore JRJ Paving — Jeff Williford