Loading...
SC-Coppell HS-LR000526FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 CLIENT: PROJECT: COMPRESSIVE STRENGTH OF MORTAR CUBES Coppell lSD, c/o Dal - Mac Construction Co. Coppell High School, Multi Purpose Building Coppell, Texas Report Date: May 26, 2000 Project No.: 0791-2208 SAMPLE DATE: April 27, 000 Contractor: Method of Test: Sample Location: Time Batched: Results / Remarks: Dal Mac / C & D ASTM C-109 K-15 Course 6 Type N Time Sampled: SAMPLE AGE DATE AREA APPLIED COMPRESSIVE REQUIRED NUMBER TESTED LOAD STRENGTH STRENGTH (days) (sq. in.) (lbs.) (psi) (psi/da)s) CHC67 7 05/04/00 4.0 5300 1330 750~28 CHC68 7 05/04/00 4.0 5520 1380 CHC 69 7 05/04/00 4.0 5180 1300 CHC 70 28 05/25/00 4.0 9040 2260 CHC 71 28 05/25/00 4.0 9420 2360 CHC72 28 05/25100 4.0 9630 2410 Remarks: Mike Flute Technician Ambient Temperature: 67° Mortar Temperature: 67° FUGRO SOUTH INC. SMH/rm Distribution: DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Williford Reviewed By: FUGRO SOUTH, INC. 2880 Vlrgo I.~ne; Datlas, Tax~ 7522~ Ph (972) 484-8301; Fax (972) 620-7328 CLIENT: PROJECT: COMPRESSIVE STRENGTH OF GROUT REPORT Coppell lSD, c/o Dal - Mac Construction Co. Report Date: May 26, 2000 Coppell High School, Multi Purpose Building Project No.: 0791-2208 Coppell, Texas SAMPLE DATE: April 27, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): GROUT TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: C&D Overcast Course 30, R-11 GROUT SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C-231) WATER ADDED: SLUMP (inches) (ASTM C-143) GROUT CYLINDER COMPRESSIVE STRENGTH TESTS Standard 3" x 6", 7.07 squara inches CYLINDER AGE DATE TOTAL LOAD COMPRESSIVE REQUIRED COMPRESSIVE NUMBER (days) TESTED (pounds) STRENGTH STRENGTH (psi) (psi) CHC 21 12 05/09/00 3260 460* 2400/28 da~/s CHC 22 28 05/25/00 4870 690* CHC 23 28 05/25/00 4600 650* CHC 24 56 06/22/00 Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curing: REMARKS: * Possible Iow 28 day test results based on 7 day results. · Does not meet required compressive strength at 28 days. Technician: Mike Flute SMH/rm Distribution: DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike EImore JRJ Paving - Jeff Williford FUGRO SOUTH, INC. Reviewed B~