Loading...
SC-Coppell HS-LR 990927FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 OBSERVATION OF CONCRETE PLACEMENT CLIENT: Coppell lSD, c/o Del - Mac Construction Co. REPORT DATE: September 27, 1999 PROJECT: Coppell High School, Coppell, Texas PROJECT NO: 0791-2208 I DATE PERFORMED: September 24, 1999 I General Contractor: Cortez Group Method of Test: Applicable ACl Recommendations and ASTM Standards Results I Remarks: Concrete placement observation was performed at the School Cafeteria - In Area "D" at west end of school. following location: Section of grade beam located on Line "D-6.5", between Lines "DF" and "DG" Time placement began: 1:40 p.m. Time placement ended: - Total cubic yards placed: - Slump range (inches): 6.0 to 6.0 Slump required (inches): 5 Concrete supplier and plant: Lattimore - Plant No. 7 Concrete temperature range (°F): 900F Strength required (psi/days): 3000/28 Number of cylinders made: 1 set of 4 cylinders Superplasticizer used: No Darrell Galloway Fugro South Technician FUGRO SOUTH, INC. Reviewed By: ~ SMH/bg Distribution: Del-Mac Construction - Damon Norman City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike EImore JRJ Paving - Jeff Williford FUGRO SOUTH, INC. E~~i" 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell lSD, c. Jo Dal - Mac Construction Co. REPORT DATE: September 27, 1999 PROJECT: Coppell High School, Coppell, Texas PROJECT NO: 0791-2208 SAMPLE DATE: August 26, 1999 I CONTRACTOR: Cortez Group TICKET NO.: 3090859 CONCRETE SUPPLIER: Lattimore AMBIENT TEMP. (°F): 101 PLANT/TRUCK: 3/762 CONCRETE TEMP. (°F) (ASTM C-10S4): 90 MIX ID NUMBER: 16 TIME BATCHED: 4:48 AIR (%) (ASTM C-231): TIME SAMPLED: 5.25 WATER ADDED (gal): 0 WEATHER CONDITION: Clear SLUMP (in.) (ASTM C-143): 3.50 LOCATION OF PLACEMENT: Pier # 131 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CHC 53 7 09/02/99 95000 3360 ~ 3000~28 days CHC 54 28 09~23/99 118000 4170 CHC 55 28 09/23/99 115000 4070 CHC 56 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ [~ ~ Cudng: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Thomas Cranford FUGRO SOUTH INC. Reviewed By: '- ~/ SMH/rm Distribution: DaI-Mac Construction- Dampn Norman City of Coppell - Larry Davis/ Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Williford