SC-Coppell HS-LR000721FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Coppell lSD, c/o Dal - Mac Construction Co. Coppell High School, Tennis Court/Parking Lot Coppell, Texas Report Date: July 21, 2000 Project No.: 0791-2208 SAMPLE DATE: June 23, 2000 CONTRACTOR: The Cortez Group TICKET NO,: 0886710 AMBIENT TEMP. (°F): 89 CONCRETE TEMP. (°F) (ASTMC-1064): 92 TIME BATCHED: 8:54 TIME SAMPLED: 9:50 WEATHER CONDITION: Warm LOCATION OF PLACEMENT: CONCRETE SUPPLIER: Lattimore PLANT/TRUCK: 7/757 MIX ID NUMBER: 88 AIR (%) (ASTM C.23'1): 4.5 WATER ADDED (gal): 10 SLUMP (in.) (ASTM C-143): 3 Tennis court approach 250 feet north CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CHC 1266 7 06/30/00 109900 3890 3000/28 days CHC 1267 28 07/21/00 137000 4850 CHC 1268 28 07/21/00 140300 4960 CHC 1269 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof ~ [~ [~ D Curing: Methods: ASTM C-39 Fracture: A El, C D REMARKS: Unit Weight: 146.0 lbs/cu, ft. Technician: Sammy Roberts FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: ~ · DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Williford FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Coppell lSD, c/o Dal- Mac Construction Co. Coppell High School, Tennis Court/Parking Lot Coppell, Texas Report Date: July 21,2000 Project No.: 0791-2208 SAMPLE DATE: June 23, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: The Cortez Group 106471 CONCRETE SUPPLIER: Lattimore 89 PLANT/TRUCK: 3/937 88 MIX ID NUMBER: 38 10:53 AIR (%) (ASTM C-231): 4 11:30 WATER ADDED (gal): 10 Partly cloudy SLUMP (in.) (ASTM C-'143): 4.5 Tennis court approach 450 feet CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CHC 1270 7 06/30/00 88500 3130 3000/28 days CHC 1271 28 07/21/00 123400 4370 CHC 1272 28 07/21/00 121000 4280 CHC 1273 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof ~] ~ ~ D Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Unit Weight: 144.0 lbs/cu, ft. Technician: SMH/rm Distribution: Sammy Roberts FUGRO SOUTH INC. Reviewed By: ~ DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Williford FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Coppell lSD, c/o Dal - Mac Construction Co. Coppell High School, Tennis Court/Parking Lot Coppell, Texas Report Date: July 21, 2000 Project No.: 0791-2208 SAMPLE DATE: June 23, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C.1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: The Cortez Group 106498 CONCRETE SUPPLIER: Lattimore 89 PLANT/TRUCK: 834/3 90 MIX ID NUMBER: 38 1:22 AIR (%) (ASTM C-231): 4.5 1:45 WATER ADDED (gal): 5 Partly cloudy SLUMP (in.) (ASTM C-143): 300 feet west, 200 feet east, 225 feet off fire lane of tennis court south corners CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CHC 1274 7 06/30/00 93200 3330 3000/28 days CHC 1275 28 07/21/00 122800 4340 CHC 1276 28 07/21/00 119100 4210 CHC 1277 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ ~ ~ ]'-'] Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Unit Weight: 148.5 lbs/cu, ft. Technician: SMH/rm Distribution: Sammy Roberts FUGRO SOUTH INC. Reviewed By: DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Williford