SC-Coppell HS-LR000707FUGRO SOUTH, INC. Ph (972) 484-8301; Fax (9/2) 620.7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Coppell lSD, c/o Dal - Mac Construction Co. Coppell High School, Tennis Court/Parking Lot Coppell, Texas Report Date: July 7, 2000 Project No.: 0791-2208 SAMPLE DATE: June 29, 2000 CONTRACTOR: Cortez Group TICKET NO.: 077845. AMBIENT TEMP. (°F): 89 CONCRETE TEMP. (°F) (ASTM C-10S4): 88 TIME BATCHED: 8:41 TIME SAMPLED: 9:45 WEATHER CONDITION: Sunny LOCATION OF PLACEMENT: CONCRETE SUPPLIER: Lattimore PLANT/TRUCK: 14/776 MIX ID NUMBER: 38 AIR (%) (ASWa C-231): 4.0 WATER ADDED (gal): 0 SLUMP (in.) (ASWa C-t43): 5 Parking lot, 175 feet offfire lane north, 50 feet off west curb line CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 aquare inchea TOTAL COMPRESSIVE SPECiRED COMPRESSIVE CYMNDER AGE DATE LOAD STRENGTH STRENGTH NUMBER Idaya) TESTED (pounds) (psi) (psi) CHC 1298 7 07/06/00 71400 2525 3000/28 days CHC 1299 28 07/27/00 CHC 1300 28 07/27/00 CHC 1201 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof ~ r'r'] r~l i-'-i Cudng: Me.ods: ASTM C-39 Fracture: AI/~J ~ [,/~ LJB c D REMARKS: Unit Weight: 146 lbs/cu, ft. Technician: Bob Shea FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Williford FUGRO SOUTH, INC. 2880 Vlrgo Lane; Dallas, T~as 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Coppell lSD, c/o Dal - Mac Construction Co. Coppell High School, Tennis Court/Parking Lot Coppell, Texas Report Date: July 7, 2000 Project No.: 0791-2208 SAMPLE DATE: June 29, 2000 CONTRACTOR: Cortez Group TICKET NO.: 088941 AMBIENT TEMP. (°F): 85 CONCRETE TEMP. (°F) (ASWa C.10S4): 89 TIME BATCHED: 5:58 TIME SAMPLED: 6:45 WEATHER CONDITION: Clear LOCATION OF PLACEMENT: CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (AsWa c-231): WATER ADDED (gal): SLUMP (in.) (ASWa C-~43): Lattimore 7/1040 38 W/R Air 10 3 Parking lot 17 feet south off center of ~2 light standard, 5 feet west off curb CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH , ,NUMBER (days) TESTED (pounds) (psi) (psi) CHC 1290 7 07/06/00 102100 3610 3000/28 days CHC 1291 28 07/27/00 CHC 1292 28 07/27/00 CHC 1293 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof ~ I-r'l r-~ i-"1 curing: Methods: ASTM C-39 Fracture: AI/~ ~ [/~ L.jB c D REMARKS: Technician: Sammy Roberts FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Etmore JRJ Paving - Jeff Williford FUGRO SOUTH, INC. 2880 Virgo lane; Dal~, Tex~ 75229 Ph (972) 484-6301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Coppell lSD, c/o Dal - Mac Construction Co. Coppell High School, Tennis Court/Parking Lot Coppell, Texas Report Date: July 7, 2000 Project No.: 0791-2208 SAMPLE DATE: June 29, 2000 CONTRACTOR: Cortez Group TICKET NO.: 0880954 AMBIENT TEMP. (°F): 89 CONCRETE TEMP. (°F) (ASTM C-t064): 88 TIME BATCHED: 7:50 TIME SAMPLED: 8:30 WEATHER CONDITION: Sunny LOCATION OF PLACEMENT: CONCRETE SUPPLIER: Lattimore PLANT/TRUCK: 7~947 MIX ID NUMBER: 38 AIR (%) (ASTM C-231): 4.2 WATER ADDED (gal): 0 SLUMP (in.) (ASTM C-t43): 5 Parking lot 150 feet off of #3 light standard west side of tennis court, 5 ff. off of southwest corner leave out CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYMNDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CHC 1294 7 07/06~00 81300 2880 3000/28 days CHC 1295 28 07/27/00 CHC 1296 28 07/27/00 CHC 1297 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C.31 Testing ASTM C-143, Typesof ~] [~] ~ ~ Cudng: Methods: ASTM C-39 Fracture: A B C D REMARKS: Unit Weight: 144.5 lbs/cu, ft. Technician: Sammy Roberts FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: ~ '" DaI-Mac Construction - Damon Norman City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Williford