Riverside Church-CS 940719 TEXAS INDUSTRIES, INC. 7610 STEMMONS FREEWAY · DALI_AS. TEXAS75247 · (214) 647-6700 ~_~ ~ ~'~ ~ ~""' Jul), 19, 199& N.B. Kibler Construction, Inc. ~V 9722 Aberna~h~ Dallas, Tx 75220 Attention W.B. Kibler RE: Church of Latter Day Saints 8271 0045 8273 Gentlemen: The attached concrete mix designs utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate are proposed for use on the above referenced project for ready mix concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas industries certifies that the above mix designs, when ordered by specified design identity, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of ACI Building Code. TXI would like to be included on your mailing list to receive alt test reports. ASTM C g4-86a Section 14.4 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Please contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix designs prior to their use. To ensure that the proper mix designs are ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TEXAS INDUSTRIES, INC. Dana L. Link Customer Service Representative MIX # 8273 5.50SK ADMIX/AEA 1"CS 4000 PSI @ 28 Days AS REQUIRED Maximum Coarse Aggregate Size: ASTM C 33 1"- #4 Crushed Stone Maximum Water/Cement Ratio: 5.82 gal/sk .515 lb/lb Minimum Cement Content per Cubic Yard: 5.50 sacks Maximum Placement Slump: 5.0 inches Admixture ASTM C-494: Type A or D Air Entraining Agent ASTM C-260: 3% - 6% MATERIAL QUANTITIES PER i CUBIC YARD AT S.S.D. 517 lbs. or 5.50 sacks ASTM C 150 Type i Cement 1840 lbs. ASTM C 33 1''- #4 Crushed Stone 1313 lbs. ASTM C 33 Concrete Sand 267 lbs. or 32.0 gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type D Specified Air Content: 3% - 6% Placement Slump: 4.0 + or - i inches ~'APPROVEO rlAPPROVED AS NOTED r'l D: ~,~P PROV L~ ~) -R_--,~ U ~.'-.; iT ~HEC;..'.-_.') FOR GENERAL CO,','70.7'; "-y TO PLAI~.'3 ~, CPEC,~ A,~ TO OVE~.'.LL ' -_~ $1ON$ AND ~JAN'ITI'IE~ AND C~"_ ~ELIE~'E SUBMII'FO~ OF REsPc;;" .TY FOR CONFORMI?~ 1'O 1'HE CO;;i". ;.'. ~'1' DOCUME~S, wA maLE. CO.STRUO;;S: . TEXAS INDUSTRIES, INC. CONCRETE DESIGN EVALUATION Date: 07/19/94 ** Statistics Compiled From independent Laboratory Test Specimens ** Page: 1 Mix No. $273 Strength 4000 psi @ 28 Days 28 Day Test Data Test Plant Temperature Placement Percent ....... 28 Day ....... Cum Moving No. Date No. Amb Con Slump of Air PSI 1 PSI 2 PSI Avg Avg Avg of 3 Range 1 12/07/93 31 46 58 6.0 3.5 5051 5089 5070 5070 5070 38 2 12/10/93 18 68 67 5.0 N/A 4170 4250 42i0 4640 4640 80 3 12/16/93 31 49 58 7.0 N/A 4732 4775 4754 4678 4678 43 4 12/16/93 31 49 60 6.0 N/A 4778 4902 4840 4719 4601 124 5 12/20/93 31 40 55 4.7 4.5 4670 4950 4810 4737 4801 280 6 12/20/93 31 39 59 3.7 4.0 5310 5480 5395 4847 5015 170 7 12/20/93 46 59 4 4.5 N/A 4780 4950 4865 4849 5023 8 12/22/93 31 37 53 4.5 N/A 56!3 545~ 5534 4935 5255 159 9 12/27/93 18 60 N/A 6.2 N/A 5220 5220 5220 4956 52C6 !0 12/27/93 4i 52 59 3.5 ~.0 5310 5240 5275 4997 5343 70 ~'_~ 12/30/93 ..... ~! :: 70 3.5 4 ~ 4930 5171 5051 5002 5182 241 12 12/30/93 3! 55 79 4.0 4.S 4976 4608 ~792 4985 5039 368 13 01/03/94 31 45 57 4.7 3.5 4780 ~880 4830 4973 4891 14 01/03/94 31 36 5i 3.0 4.5 5!30 5020 5075 4980 4899 !10 -~ 01/03/94 31 37 -' 3.5 L.2 5130 5340 5235 ~997 ~ . 210 15 01/04/94 12 50 60 4.2 N/'A 4860 4770 ~815 ~986 5042 90 !7 01/05/94 41 66 67 5.9 4.5 4780 4850 4815 ~976 4955 7C i8 01/05/94 41 56 59 4.5 5.3 4670 4600 ~635 ~957 4755 70 !9 01/05/94 31 49 5~ 4.2 4.5 4810 71.~ 476G 4946 4737 !00 20 01/05/94 31 42 55 4.0 4.0 4630 4530 4580 4928 4658 100 2! 0i/13/94 31 59 47 4.5 4.5 5060 4950 5005 4932 4782 110 22 01/13/94 31 58 45 4.2 4.C 4740 4780 4750 4924 4782 40 23 01/13/94 31 52 52 4.0 4.0 4950 5060 5005 4927 4923 !10 24 01/14/94 31 60 57 3.7 4.0 5130 5270 5200 4939 4988 140 25 01/14/94 31 48 59 4.3 5.C 4850 4710 4780 4932 4gg5 140 26 01/14/94 31 43 54 4.7 4.0 ~320 4420 4370 e911 4783 !00 27 01/14/94 38 N/A 67 5.0 5.3 4900 4870 4885 ~910 4678 30 28 0i/19/94 38 N/A 54 5.0 5.3 4830 4930 4880 ~909 4712 100 29 01/24/94 38 N/A 50 5.C 4.7 g420 442~ ~420 4892 4728 30 0!/28/94 38 N/A 55 4.7 5.0 ~940 516C 5053 ~897 4783 220 '** Averages '** 5! 56 4.6 4.3 COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix No. 8273 Strength 4000 psi @ 28 Days Paragraph 5.5 of ACi 318-89 provides that as data becomes available during construction, the amount by which (f'cr) must exceed the specified value of (f') may be reduced, provided: c (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15' to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.!.2 and is the larger value of these calculations f' : f' + 1.34(SD) cr c = 4000 + 1.34(00294) : 4394 f' = f' + 2.33(SD) - 500 cr c = 4000 + 2.33(00294) - 500 = 4185 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 3~ Maximum Va~ue ............................ 5534 psi Minimum Value ............................ 4210 psi Range .................................... 1324 psi Average Strength ......................... 4897 psi Standard Deviation ....................... 294 psi Required Average Strength to satisfy minimum probability conuitions of ACI 318-89 Section 5.3.2.! ............... 4394 psi Design excess beyond code requirements.. 503 psi Construction Products Division ~ W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 June 16, 1994 Mr. Dana Link TXI 7610 Stemmons Freeway Dallas, TX 75247 Gentlemen: This is to certify that DARATARD-17, a water-reducing set- retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, as a Type B & D admixture; and the Standard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD-17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 16th day of June, 1994 A.D. We hope the information given here will be helpful It ~s based on our best knowledge, and we beheve it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods suppl.ed by us. We assume no responsibilih/for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any uSe which would infringe any patent or copyright. Construction Products Division ~ W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 June 16, 1994 Mr. Dana Link TXI 7610 Stemmons Freeway Dallas, TX 75247 Gentlemen: This is to certify that WRDA with HYCOL, a water-reducing admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, Type A (AASHTO M194, Type A). No chlorides or halogens are added to WRDA with HYCOL as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. rely,// Tom C. Henson District Manager Subscribed and sworn to, before me, this 16th day of June, 1994 A.D. Notary Nota~ ~ubllc, S~te of Te~s My Commi~ion E~ires 10-20-97 We hope the info~mahon g~ven here will be helpful. It i~ ~sed on our be~t knowledge, ond we believe it lo be lrue and occu~a~e. Please read ~11 slolemenls, r~ommendolions or ~uggesnon~ herei~ in conjunction wi~h our ¢o~dilion~ oJ ~le which opply to ~11 go~s suppli~ by us. We o~ume no res~nsi~ili~ for of these stotemenls, ~ecommen~ations, or suggestions, nor do we mlend Ihe~n 05 a re¢ommenda1~on for any use w~ich wouJd infringe any ~tent or ¢opyrighl. Construction Products Division ~ W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 June 16, 1994 Mr. Dana Link TXI 7610 Stemmons Freeway Dallas, TX 75247 Gentlemen: This is to certify that DAREX II AEA, an air-entraining admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specification for Air-Entraining Admixtures for Concrete, ASTM Designation: C-260 (AASHTO M 154). DAREX II AEA does not contain calcium chloride or chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. ely, Tom ¢. Hon$on District ~ana~er Subscribed and sworn to, before me, this 16th day of June, 1994 A.D. We hope the informal,on given here will be helpful. It is based on our best knowledge, and we beheve ~t to be true and accurate. Please read all statements, recommendol,ons or suggeslions herein in coniunclion with our cond~hons of sale which apply to ali goods supphed by us. We assume no respons,bilit-/for the use of these statements, recommendations, or suggestions, nor do we inlend the,n os a recommendahon for any use wh,ch would infringe a,qy patent or copyright. TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 06/28/94 #ALL Tests Production Facility: PARADISE Size #: 33 Grading Designation: ASTM C-33 FINE AGG. Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specification Size Wt. Retained % Retained % Passing % Retained % Passing 2.0 1.5 1.0 ' 3/4 1/2 3/8 #4 1.98 98.02 0 - 5 95 - 100 #8 19.00 81.00 0 - 20 80 - 100 #10 #16 35.14 64.86 15 - 50 50 - 85 #30 49.79 50.21 40 - 75 25 - 60 #40 #50 72.42 27.58 70 90 10 - 30 #100 95.10 4.90 90 - 98 2 - 10 #200 98.86 1.14 Pan Wt. 2.73 Fineness Modulus M.C. 6.1% Sampled By: /~F~/t~ ,~ ~/~ Decant 1.05% Tested By: _ 100% of 141 tests: Size 33 Plant: PARADISE Job: ***** ALL JOBS ***~ TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 06/27/94 #ALL Tests Production Facility: BRIDGEPORT Size #: 57 Grading Designation: ASTM C-33 1'' - #4 Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specification Size Wt. Retained % Retained % Passing % Retained % Passing 2.0' 1.5' 1.0' 1.65 98.35 0 - 5 95 - 100 3/4' 17.31 82.69 1/2' 55.48 44.52 40 - 75 25 - 60 3/8' 79.41 20.59 #4 97.27 2.73 90 - 100 0 10 #8 98.80 1.20 95 - 100 0 - 5 #10 #16 #3O #4O #5O #100 #200 ' Pan Wt. Sampled By: 100% of 146 tests: Size 57 Plant: BRIDGEPORT Job: ***** ALL JOBS ***~ TEXAS INDUSTRIES, INC. CEMENT DIVISION, 245 Ward Road Midlothian, Texas 76065 SPECIFICATIONS Portland Cement Type 1/11 (Low Alkali) A.S.T.M. C150-92 A.A.S.H.T.O. M 85-911 Bin Number Car Number Tons Date of Sampling May 1994 Monthly Average I SPECIFICATIONS I TEST ASTM ,AASHTO RESULTS CHEMICAL REQUIREMENTS Silica Oxide, Minimum Percent 20.0 20.0 20.6 Alumina Oxide, Maximum Percent 6.0 6.0 4.4 iron Oxide, Maximum Percent 6.0 6.0 3.9 Magnesia Oxide, Maximum Percent 6.0 6.0 0.9 SO3 (C3A less than 8%), Maximum Percent * * 3.6 Loss on Ignition, Maximum Percent 3.0 3.0 1.8 Insoluble residue, Maximum Percent 0.75 0.75 0.25 Tricalclum Aluminate, Maximum Percent 8 8 6 Tricalcium Silicate, Maximum Percent 55 57 ...... - .... :-. OPTIONAL CHEMICAL REQUIREMENTS - Total Alkalies, Max. % (Na20 equiv.) I 0.60 I 0.60 I 0.5 .' ..... .-i "-- -PHYSICAL REQUIREMENTS ...... Specific surface, Minimum (M"2./Kg) 160 160 Wagner Maximum (M^2/Kg) ... 220 193 Specific surface, Minimum (M"2/Kg) 280 280 Blaine Maximum (M^2/Kg) 400 347 Gillmore, Initial Set, Minimum (Minutes) 60 60 175 Gillmore, Final Set, Maximum (Minutes) 600 600 295 Vicat, IMinimum (Minutes) 45 45 Initial Set lMaximum (Minutes) 375 375 114 Air Content, Volume Maximum Percent 12 12 5 Autoclave Expansion, Maximum Percent 0.80 0.80 0 3 Day Minimum Compressive Strength, PSi 1800 1800 , 3636 7 Day Minimum Compressive Strength, PSI 2800 2800 ! 4526 STATE OF TEXAS ELLIS ,,~-',~ 1 · ,,... _: . J.R. Owens , being duly sworn deooses and says; that he is Chief Chemist of e ,(-.,,e~S~',- ' Texas Industries, inc., Cement Division, who prepared the above report of tests and that the same is true and corre~. !~,. ! l Sub d and sworn to before me this 14t. day of June, 1994. ~ ~"f¢ OI; X¢g~ / %0. ,-, ~ .o~....; Ch~ Chemist · See ASTM C150 Table 1, Footnote B.