11050,4bles Ln., Dallas, Texas 75229 phone.'(972)488-8800 fax:(972)488-8080
Report of Moisture-Density Relationship
client city of coppell
Project Coppell Road Improvements Report Distribution
TMI Project No. DC-99-510
TMI Report No. DC-99-510-013
Report Date 01/08/00
Project Information
Matedal Origin: Onsite/Native Sampled By: M. Kashem
Sample Location: 12" water line @ Coppell Road @ sta 19+00 Sample Date: 01/03/00
Matedal Description: Light gray Silty CLAY Tested By: Charles Ray
Material Use: Backfill
Moisture-Density Relationship - Curve No. 6479
::[::'t't-::: .......'"" "'I
,,2.0
__;__ ,
"i'-
--i-
t..'104.0 ~ ~ I
r,
.......... ]
'_ __ _~.
100.0 i
...... ~- ] ....
.~.o" ' 'I' ',' 1 .... :' ' 1
13.0 15.0 17.0 '10.0 21.0 23.0
Mdst~re
Material Properties and Test Information - Curve No. 6479
Maximum Dry Density:
Optimum Moisture Percent:
106.2 pcf Liquid Limit: 43
17.2 % Plastic Limit: 14
Plasticity Index: 29
Test Method(s):
Rammer Descdption:
Remarks:
ASTM D698-A, D4318-B, D1140
Mechanical
Passing No. 200:
USCS:
Preparation Procedure: Moist
65.3 %