Loading...
SC-Coppell HS-LR000320FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 CLIENT: PROJECT: FIELD DENSITY REPORT Coppell lSD, c/o Dal- Mac Construction Co. REPORT DATE: March 20, 2000 Coppell High School, Stadium Expansion, Coppell, Texas PROJECT NO: 0791-2208 DATE PERFORMED: March 15, 2000 ] Density Test Method: ASTM D-2922 & 3017 MOISTURE/DENSITY RELATIONS Material Number Description Maximum Dry Density (pcf) I Red brown clayey sand (select) 116.9 Method of Compaction: ASTM D-698 Proctor Results Optimum Moisture (%) 13.5 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE NO. NO. WEIGHT CONTENT PERCENT 196 1 South Retaining Wall, Grid A-24, 1st lift 110.1 16.5 197 1 South Retaining Wall, Grid B-24, 1st lift 111.2 14.9 Remarks: *Does not meet project specifications for percent compaction. PERCENT OF MAXIMUM DENSITY 94.2* 95.1 Thomas Cranford Fugro South Technician SMH/bg Distribution: DaI-Mac Construction - Damon Norman City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Group - Joe Craddock SHW Group - Mike Elmore JRJ Paving - Jeff Wiiliford FUGRO SOUTH INC. Reviewed By: