Loading...
SC-Coppell MSW-LR001116FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas. Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 OBSERVATION OF CONCRETE PLACEMENT CLIENT: Coppell lSD, cio K A Sparks REPORT DATE: November 16, 2000 PROJECT: Coppell Middle School West, Coppell, Texas PROJECT NO: 0700-2227 DATE PERFORMED: November 13, 2000 General Contractor: Cortez Group Method of Test: Applicable ACI Recommendations and ASTM Standards Results I Remarks: Concrete placement observation was performed at the Slab on vapor barrier - Slab for storage, concession following location: and restroom facilities Time placement began: 11:00 a.m. Time placement ended: - Total cubic yards placed: 4.0 Slump range (inches): - Slump required (inches): Concrete supplier and plant: - Concrete temperature range (°F): 72 - 76°F Strength required (psi/days): 3000/28 Number of cylinders made: 4 Superplasticizer used: No Jeff Jedlicka Fugro South Technician FUGRO SOUTH, INC. Reviewed By: '~_~. ~ SMH/bg Distribution: K A Sparks Contractors Inc. - Jim Schooler K A Sparks Contractors Inc. - Rick McKinney (Fax: 972-745-4511 ) City of Coppell - Lee Stone City of Coppell - Larry Davis-,/ Coppell lSD - Mickey Harper SHW Group - Mike Elmore SHW Group - Joe Craddock FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell lSD, c/o K A Sparks Report Date: November 16, 2000 PROJECT: Coppell Middle School West, Coppell, Texas Project No.: 0700-2227 I SAMPLE DATE: October 18, 2000 I CONTRACTOR: K.A. Sparks / The Cortez Group TICKET NO.: 3114783 CONCRETE SUPPLIER: Lattimore AMBIENT TEMP. (°F): 76 PLANT/TRUCK: 3/1096 CONCRETE TEMP. (°F) (ASTM C-t064): 83 MIX ID NUMBER: 38 TIME BATCHED: 12:52 pm AIR (%) (ASTM C-231): 5.0 TIME SAMPLED: 1:45 pm WATER ADDED (gal): 0 WEATHER CONDITION: Partly cloudy SLUMP (in.) (ASTM C-143): 4.50 LOCATION OF PLACEMENT: Grade beams for concession & restroom building, sampled at west grade beam CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days} TESTED (pounds} (psi} (psi} CMW 121 7 10/25/00 94400 3360 3000/28 days CMW 122 28 11/15/00 125100 4430 CMW 123 28 11/15/00 122600 4340 CMW 124 Hold Fracture mode is (A) unless othenvise noted Specifications: Making & ASTM C-31 Testing ASTM C-143. Typesof [~] [~] [~ [~] Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Jose Rivera FUGRO SOUTH INC. Reviewed By: ,-~ SMH/rm Distribution: K A Sparks Contractors Inc. - Jim Schooler K A Sparks Contractors Inc. - Rick McKinney (Fax: 972-745-4511 ) City of Coppell - Lee Stone City of Coppell - Larry Davis ~ Coppell lSD - Mickey Harper SHW Goup - Mike Elmore SHW Goup - Joe Craddock