Loading...
SC-Coppell MSW-LR001027FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell lSD, c/o K A Sparks Report Date: October 27, 2000 PROJECT: Coppell Middle School West, Coppell, Texas Project No.: 0700-2227 SAMPLE DATE: October 18, 2000 CONTRACTOR: K.A. Sparks / The Cortez Group TICKET NO.: 3114783 CONCRETE SUPPLIER: Lattimore AMBIENT TEMP. (°F): 76 PLANT/TRUCK: 3/1096 CONCRETE TEMP. (°F) (ASTM C-1064): 83 MIX ID NUMBER: 38 TIME BATCHED: 12:52 pm AIR (%) (ASTM C-231): 5.0 TIME SAMPLED: 1:45 pm WATER ADDED (gal): 0 WEATHER CONDITION: Partly cloudy SLUMP (in.) (ASTM C-'143) .' 4.50 LOCATION OF PLACEMENT: Grade beams for concession & restroom building, sampled at west grade beam CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMW 121 7 10/25/00 94400 3360 3000/28 days CMW 122 28 11/15/00 CMW 123 28 11/15/00 CMW 124 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof r~l ~-~ ~--~ N Curing: Methods: ASTM C-39 Fracture: AI/%J [/XJ [/~ L..JB c D REMARKS: Technician: Jose Rivera FUGRO SOUTH INC. Reviewed By: ~ j' SMH/rm Distribution: K A Sparks Contractors Inc. - Jim Schooler K A Sparks Contractors Inc. - Rick McKinney (Fax: 972-745-4511 ) City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Coup - Mike Elmore SHW Coup - Joe Craddock