Loading...
SC-Coppell MSW-LR001017 _~--~i 0~0 FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell lSD, c/o K A Sparks Report Date: October 17, 2000 PROJECT: Coppell Middle School West, Coppell, Texas Project No.: 0700-2227 SAMPLE DATE: October 6, 2000 I CONTRACTOR: Cortez Group TICKET NO.: 7093693 CONCRETE SUPPLIER: Lattimore AMBIENT TEMP. (°F): 61 PLANT/TRUCK: 7/1040 CONCRETE TEMP. (°F) (ASTM C-1064): 73 MIX ID NUMBER: TIME BATCHED: 5:37 AIR (%) (ASTM C-231): 4.8 TIME SAMPLED: 6:05 WATER ADDED (gal): 10 WEATHER CONDITION: Light Rain SLUMP (in.) (ASTM C-143): 5.75 LOCATION OF PLACEMENT: East parking lot north west corner CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMW 81 7 10-13-00 93200 3300 3000/28 days CMW 82 28 11-3-00 CMW 83 28 11-3-00 CMW 84 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143. Typesof [~] [~ ~ ~ Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Thomas Smith FUGRO SOUTH INC. SMH/kp Distribution: K A Sparks Contractors Inc. - Jim Schooler K A Sparks Contractors Inc. - Rick McKinney (Fax: 972-745-4511) City of Coppell - Lee Stone City of Coppell - Larry Davis Coppell lSD - Mickey Harper SHW Goup - Mike Elmore SHW Goup - Joe Craddock