ST9602-CS 991223 MEMORANDUM FROM THE CITY OF COPPELL DEPARTMENT OF ENGINEERING To: Ivan Nicodemus, P.E. From: Kent Collins, P.E., Civil Engineer/~/~ Date: December 23, 1999 RE: CMAQ Project 10 Construction Plan Review Comments The City of Coppell Engineering Department has reviewed the referenced construction plans and offers the following comments: 1. On Sheet 25, Work Sequence #1, "Adjust Utilities (By Others)", needs to include identification of "Others" and specify which "Utilites"; City Utility relocations need to be included in the construction of the lane. 2. The legend for the Intersection Layout Sheets needs to clarify that the paving section will be concrete on an asphalt base. The City recommends using the City Standard paving section which is reinforced concrete paving on 6" lime-stabilized base. 3. On Sheet 28, a Type 4 retaining wall is not acceptable from an aesthetics standpoint. Consider using a "Keystone" or "Pavestone" gravity wall. 4. Note 4 of Sheet 30 needs to include who will relocate the railroad signal for the project. This should be included in the construction of the lane. 5. Sheet 18, Section A-A does not seem accurate compared to plan view. Can the right thru-lane actually be maintained at 3.2 m during construction? 6. Note #5 on Sheet 24 needs clarification of meaning. 7. General Note: This project should stand on its own in terms of utility relocations, etc. The City will not be responsible for relocating conflicting utilities. If you have any questions regarding these comments, please contact me at (972)304-7019. "CITY OF COPPELL ENGINEERING - EXCELLENCE BY DESIGN" 255 Parkway Blvd Coppell, TX 75019 Phone: (972)304-3679 Fax: (972)304-3570 ENGINEERING DEPARTMENT FAX CO VER SHEET To= Ivan Nicodemus From= Kent Collins Fax: 214-741-1937 Date: December23, 1999 Phone: Pages: 2 Re: CMAQ 10 Review Comments CC: [] Urgent [] For Review [] Please Comment [] Please Reply [] As Requested · Comments: Please find included The City of Coppell's review comments regarding the construction plans for CMAQ Project 10. Please call me at (972)304-7019 if you have any questions. IF YOU DO NOT RECEWE ALL OF THE PAGES, PLEASE CALL (972) 304-3679 Engineering - Excellence By Design