Loading...
SC-Town Center E8-LR 931001. one RoneE nain eer s Geotechnical Consuitants Ma[erJals Testing jConcreteTest Repo~ Cylinder ! Purchase Oraer i TOWN CENTER ELEMENTARY - COPPELL, TEXAS JNumoer ;,Dst-. cf Cbservamon iRelmor~ Date = I [D3-080C-01-24489 ! SE:PT. 23, 1993 ', OCT. 1, 1993 Fo i, COPPELL I . S-. D. iLoca~on !INTERSECTION NORTH AND EAST DRIVE i K. A. SPARKS CONTRACTORS, INC. iSuo~er i F~.an:,. '.T,%,cx . i LATTIMORE i ' 432 J !Mix Numoe; iM~x Desc.~p0ol~ ! jWeatner Condi~on$ :AmO~e?,~ iemDera%%'re ("~ '.CoDcte~e Tempe.~?. -'re j CLEAR 81 ' 83 J i"~me Samo~ed i '¥'Va~er Acoed I 10400 AM ~ 0.0 GALS iPhysical SLUMP (in.) 5 !Concrete Cviindc'r Test(s) ACTUAL SPECIFICATIONS soec:.men. Age ! Tat Load Core,reserve Sreng~ $~'eng'~ Required i Test, Da:e No. I (~ays) : (!Cs.) ¢,ps6 ,.psi'J 260 7 09~30/93 86000 3040 3000 261 28 10/21/93 262 28 10/21/93 263 HOLD HOLD Cunng Metn. od Te~ Memocl ~S.~.nda~o S' x '..2' .F.,~cineer/Tecnnic~an ASTM C 31 ASTM C 39 j~ea 28.27 sQ. in.,i - RANDY WORTHEN F{efl',,a.~$ a.n~/or gi:s-~bu'~on COPPELL I.S.D./MICKEY HARPER (1), CITY OF COPPELL/LARRY DAVIS (1), K. A. SPARKS CONTRACTORS, INC./E. J. WILLIAMS (1) , S.H.W.I.N.C./ MIKE ELMORE (1), S.H.W.I.N.C./JOE CRADDOCK, V.P. (1), K. A. SPARKS CONTRACTORS, INC./E.J.WILLIAMS (1) ! Rone Engin .,er',, ,=lone Engineers RoneE naJneers Geotechnical Consu~ants Matedais Testing !Concrete Cylinder Test Report I Pur~e ~oer jProj~ I , TO~ CENTER EL~ENT~Y - COPPELL, TE~S [Numar i~te of O~e~on ~D3-080C-01-24489-A ~ SEPT. 23, 1993 CT. 1, 1993 ~o ~ COPPELL I.S.D. ~L~on I INTERSECTION OF H~TS ~D NORTH DRIVE ~ K. A. SPA~S CONT~CTORS, INC. 'CLEAR I 12.: 00 NOON 0.0 GALS ACTUAL SLUMP (in.) 5 1/2 Concrete Cyiinder Test(s) ACTUAL SPECIFICATIONS Soec:men j Age I Tot ~caa ~moress~e ~---"c'e-nGm S~ng~t R~uir~ No.i (Days1 ~ T~ Date 264 7 09/30/93 112000 3960 3000 265 28 10/21/93 266 28 10/21/93 267 HOLD HOLD iCunng Me,J'too Test Me~cx:i ¢Stanca~'d S' x 12' h=.%c,neer/Tecnnic;an ~A~ea 28.27 sc. !n. i 'RANDY WORTHEN !ASTM C 31 ASTM C 39 j , !Remarxs ~3d/or O~bulJon COPPELL Z.S.D./MICKE¥ FJ~PER (1), CITY OF COPPELT./ZJLRR¥ DAVIS (1), K. A. SPY's, KS CONT~CTORS, INC./E. J. WILLI~'v[S (1), S.H.W.I.N.C./ MIKE ET_~ORE (1), S.H.W.Z.N.C./JOE CR~DDOCK, V.P. (1), K. A. SPkR.KS CONTRACTORS, INC./E.J.eIT,LI~V~S (1) Rone Engineers Rone Engineers RoneE naineers Geotechnical Consultants Materials Tesdng !Concrete Cylinder Test Report j Purc-nase Oroer !TOWN CENTER ELEMENTARY - COPPELL, TEXAS ~Numbe-r iDme of Obsem,a~on !Re.r:~rt Date i D3-080C-01-24489-B i SEPT. 23, 1993 ! OCT. 1, 1993 rTo COPPELL I.S.. D. EAST PARKING, 25' FROM THE NORTH/SOUTH END K. A. SPARKS CONTRACTORS, INC. ~Supc,~er [?,ant,, :Tr, Jc~( iTic~<e.' LATTIMORE ' ! 332 ! M~ Num~-,e_r iMLx Descnp~ion Weather Condi-~ons I.~,-n c~. ,"ri, Tem::~'a,'ure,'°n.. .l'Conc~' ~e Temoer~re. ',.° .~ CLEAR ' U..me S~..'n.,c~ec ! Water Acoec 1:.30 PM i 0.0 GALS ~Dhvsicai Data A'"~-'.~' SPEC:FiCATiONS SLUMP (in.) 5 !Concrete Cyiinder Test(s) I ACTUAL SPECIFICATIONS S _oec~.men i Age iI Tot Load ' Comoressrve Slrenc3~ S~'en_cr~ Reou~red NO. ! (IDavs) i Tes~. Date ilb$.) i t, psB (psB 268 7 09/30/93 95000 3360 3000 i 269 28 10/21/93 · ! 270 ~-8 z0/21/93 i 271 HOLD HOLD I I Cunng Me~c~ iTe~ Me~ocl iStancm'd 6' x 12" ~F_..,3g~neer/Tecnnic~an !ASTM C 31 !AS'TM C 39 ,[Area 28.27 sci. :n. i RANDY WORTHEN IRemar~s and/or D~-mb,.n/on COPPELL I.S.D./MICKEY HARPER (1), CITY OF COPPELL/LARRY DAVIS (1), K. A. SPARKS CONTRACTORS, INC./E. J. WILLIAMS (1), S.H.W.I.N.C./ MIKE ELMORE (1), S.H.W.I.N.C./JOE CRADDOCK, V.P. (1), K. A. SPARKS CONTRACTORS, INC./E.J.WILLIAMS (1) Rone Engineer', Rone Engineers R o n e E n nee r s Geotechnicai Consu,~ants Materials -Fest!ng Concrete Cylinder Test Repo~ ~ Purchase Oroer i TOWN CENTER ELEMENTARY - COPPELL, TEXAS :Number iD-a=e o; C,-,serva.aon P, eDort 'Date i D3-080C-01-24489-C ~ SEPT, 23, 1993 ! OCT, 1, 1993 [ EAST PARKING, 100' FROM THE NORTH/SOUTH END { K. A. SPARKS CONTRACTORS, INC. iSu=.c.~er ;P~a,"r: 3 0 8 i LATTIMORE ~ iM~x Numoer :M~x Descn0con I iWeafner Con~iSon~. !.~-I1,::~'e~ Temc, erat~:re !CLEAR ! 2:.10 PM ~. 0.0 GALS ~:Physicai Data ACTUAL SP- C~F,,.,~T1ONS SLUMP (in.) 5 1/2 Concrete Cylinder Test(s) ACTUAL SPECiFiCATIONS Soec~.men Age ; Tes~ Dste Tot Load C, omDre~sive S~ng%'~ Stone Rmuir~ . . ' (,~s.~ ~r, (ps,1 272 7 09/30/93 108000 3820 3000 273 28 10/21/93 274 28 10/21/93 275 HOLD HOLD Cunng Memo<3 iTes~ Med~od !St3ncard S' x I~ ~,~?~n,~ ?e~ ~s.27 sq. in. ~DY WORTHEN ~ C 31 tASTM C 39 Rms ~d/or COPPELL Z.S.D./MICKEY ~PER (~), CITY OF COPPELL/~Y DAVZS (~), K. A. SPaS CONT~CTORS, ZNC./E. J. WILLIES ([), S.~.W.Z.N.C./ MIKE E~ORE (1), S.H.W.I.N.C./JOE C~DDOCK, V.P. (1), K. A. SPaS CONT~CTORS, ZNC./E.J.WZLLZ~S (~) Rone Engineers Ro., R0neE n ineer s Geotecnnicai Consultants Materials Testing Concrete Cylinder Test Repor~ Pro;_--c:_. i Purchase Oroer TOWN CENTER ELEMENTARY - COPPELL, TEXAS I Numoer -' :u--~te ot Oc~serv~on !Report .Dm~e D3-080C-01-24489-D SEPT. 23, 1993 To COPPELL I. S-. D. Lock, on EAST PARKING, 125' FROM THE NORTH/SOUTH END K. A. SPARKS CONTRACTORS, INC. Sucker ?'.a.-,,. ;Truck i~cKet LATTIMORE i ~ 328 IM~x Number ,M~ 'Weaf~her Con~-ibons iAm,~ie-~ Tempera.'ure ,om IC. onctme Temoe,'-a~.~re ,cc-, i CLEAR ..-5.,.me Samo~ec . Water 3:00 PM 0.0 GALS '=hvs~ca~ Data SLUMP (in.) 5 1/2 iConcrete Cyiinder Test(s' , ACTUAL SPECiFiCATIONS iS .oec:..men :. Aae Tct Load Comoress~ve S"crenq~ St~ncj~. Requirec~ - ' fibs.) {?-'si'J [psr~ NO. I (Days) ; . 276 7 09/30/93 71000 2510 3000 277 28 10/21/93 278 28 10121193 279 HOLD HOLD Geotechnical Consultants Ma[erims Testing Concrete Cylinder Test Repo~ Projec':.. jPurcnase Order TOWN CENTER ELEMENTARY - COPPELL, TEXAS Number ' ;Oa,~e o,~ O~servaZion Report Date D3-080C-01-24489-E J SEPT. 23, 1993 ' O~m_ 1 , lqq3 ' COPPELL I S;D. ]Loca.~on EAST P~R.KZNG, ].7 5 ¢ FRO~ THE ~O~TH/SOUTH END K. A. SPARKS CONTRACTORS, INC· !Su~.~ er i P~-~., '.Truck i'Pc~ et i LATTIMORE ~ ( 432 JMix Numoe-r ;Mix Desc. dp~on :'¢v'~_amer Conair. OhS i.,~m,m'em Temperature C?,, !Concrete Tem.oemmre i CLEAR ~'%me Sam.~e'~ ; Water Aao~ , 4:10 PM : 0 0 GALS i ' ',Physica! Data AC, UA,. SPECIFiCA~ONS SLUMP (in.) 5 3/4 '.Concrete Cylinder Zest(s) i ACTUAL SPECIFICATIONS ISc>ec~.m_n j Age , i Tot Loac~ C. omccre.csive S~ncj~ St~ng'~ Re~uirec~ i No ~ (Days) j Te~-t Date 280 7 09/30/93 75000 2650 3000 281 28 10/21/93 282 28 10/21/93 283 HOLD HOLD JCunng Me.od :Test Memod jSt~uccarcl 6' x !2' !-=.'~c~n_~er/TecnnJciaJ3 I JArea 2827 $~3. in. , !ASTM C 31 IASTM C 39 - i RANDY WORTHEN :Re~m.~xs and/or O~-'4~bu~on COPPELL I.S.D./MICKEY HARPER (1), CITY OF COPPELL/LARRY DAVIS (1), K. A. SPARKS CONTRACTORS, ZNC./E. J. WILLIAMS (1), S.H.W.T.N.C./ MIKE ELMORE (1), S.H.W.I.N.C./JOE CRADDOCK, V.P. (1), K. A. SPkRKS CONTRACTORS, INC./E.J.WILLTAMS Rone Engineers