ST9801-LR000802 (3)~ZXJ'I~J'IBC, J~ bgileerinl CI. 9200 King Arthur Drive Dallas, Texas 75247-3610 Phone 214/631-4372 Fax 214/631-4380 CONCRETE COMPRESSION TEST REPORT Report No.: Location: 93 Job No.: Box Culvert from Sta, 3+29 to 3+41 Contractor: Ed Bell Construction Reported To: City of Coppell - Kenneth Griffin, P.E. (6 x 12 Inch) Nominal Cylinder Size: Area - 28.27 SO. IN. Field Number: Test Date: Maximum Load, LBS: Age When Tested, Days: Compressive Strength, PSh Average Strength, PSh Type Break: Conical (U.N.O.) Remarks: 1520COP03 Date Cast: Specification: Quantity Represented: Sampled By: By Order Of: 08/02/00 3500 psi @ 28 days 10 of 50 M. Kashem CP080201 CP080202 CP080203 CP080204 08/09/00 08/30/00 08/30/00 HOLD 76390 7 28 28 HOLD 2700 Temperature: Ambient Time of Sample: Source of Concrete: 88 ° F 10:55 AM Pioneer- 9339 Mix 90 ° F Air Content N/A % Slump 5.00 Inches Pick-Up Charge: Yes N/A Ticket No.: 675412 Fine Aggregate: Coarse Aggregate: Water: Cement: Fly Ash: Admixture(s): Distribution: Unit Weight PCF Yield CF/CY City of Coppell - Larry Davis ~,~.g/z-~~ , i ne Page 1 ~ Test Methods: ASTM C 31, C 39, C 173, C 192, C 231 and C 1064 OUR LETTERS AND REPORTS ARE FOR THE EXCLUSIVE USE OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND APPLY ONLY TO THE SAMPLES TESTED. TEST RESULTS ARE NOT NECESSARILY INDICATIVE OF THE QUALITY OF APPARENTLY IDENTICAL OR SIMILAR SAMPLES. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE APPROVAL OF STANTECH.