Loading...
SC-Town Center E8-LR 930830 Rone F_nglneers RoneE !ineers Geotechnical Consu,~ants Materials Testing !Concrete Cylinder Test Report Projec~ IIPUrchase CXder TOWN CENTER ELEMENTARY - COPPELL, Tw. XAS ! Number " Da4e of Observa~on IReport Dine D3-080C-01-23650 ! JULY 30, 1993 i AUGUST 30, 1993 Fo I COPPELL I S D. GRADE BEAM BETWEEN PIERS 7M & 10M iC.o~b-a~or K. A. SPARKS CONTRACTORS, INC. !Supp,~er iP~nt iTruck !'ricke! ! U~TT~MORE ' 6 i 409 ! 098929 !Mix Number i.M.'k Description Weather Ccnci;bons iA,mbiem Tem.::~.ramre ¢'F),, !Concrete Tempem,~re (0~ CLEAR ~ 98 ! 94 ~,me Sampled i Water Adoed 13.=20 AM ~ 3.0.0 GAf,S Physical Data AC ;U, ,,- SPECIFICA~ONS SLUMP (in.) 4 Concrete Cylinder Test(s) ACTUAL SPECIFICATIONS Specimen Age i Tct Load I Comc~ressive S~ng~ S,-"enc3~ Required No. (Days) Test, Date I I I I I 3.16 7 08/06/93 85000 3010 3000 117 28 08/27/93 111000 3930 118 28 08/27/93 104000 3680 Curing Me,in. od Test MethOO iS.~.'~card S" x 12' JFEngineer/Tecnnician . iAtea 28.27 sq. in. , GEORGE BEALL (RONE) ASTM C 31 IASTM C 39 ~ ,. Ren'm~s and/or Dism-ou'don : COPPELL T.S.D./MTCKEY HARPER (1), CITY OF COPPELL/LARRY DAVIS (1), K. A. SPARKS CONTRACTORS, INC./E. J. WI~.LIAMS (~), S.H.W.T.N.C./ MIKE E~ORE (1), S.H.W.I.N.C./JOE CRADDOCK, V.P. (~), K. A. SPARKS CONTRACTORS, INC./E.J.WZLLIAMS (~) Ron er.,