Smart Start-CS 990527The City With A Beautiful Future P.O. BOX 478 COPPELL. TEXAS 75019 May 27, 1999 Richard Akin, P.E. Jones and Boyd, Inc. 16800 Dallas Parkway, Suite 240 Dallas, TX 75248 RE: Smart Start School Dear Mr. Akin: at d P.O. Box 478 Coppell. Texas 75019 972 - 462 -0022 FILE The City of Coppell has reviewed the referenced plans and has the following comments to offer: 1. Please try to clean up the site plan so that it is easier to read. Make the different line types /weights more distinct and since the grades are shown on other sheets, you can remove the contours from this sheet. 2. The proposed fire hydrant needs to be within 3' of the fire lane. 3. A letter needs to be submitted to the City Engineer requesting a variance to the Subdivision Ordinance paving requirements for lime - stabilized subgrade. Increased concrete strength and 95% subgrade compaction in lieu of lime stabilized subgrade has been approved in the past. 4. An off -site drainage easement will be required for the proposed drainage work to the south of the property. 5. The area of the future hike and bike trail adjacent to the property needs to be graded to a 2 % cross -slope as part of this development. 6. Provide a profile for the proposed 8" public sanitary sewer. 7. Locate water meters such that they do not fall within the proposed sidewalk. There are various other minor comments throughout the plans. When all comments have been addressed, please return these marked plans and two sets of revised plans to the City for review. If you have any questions, please contact me at (972) 304 -7019. Sincerely, &dd Kent M. Collins, E.I.T. Graduate Engineer