Loading...
Smart Start-CS 981119P & Z HEARING DATE: November 19, 1998 C.C. HEARING DATE: December 8, 1998 i): l 1 14 CITIN a s i ; 110N1\ LOCATION: SIZE OF AREA: CURRENT ZONING: REQUEST: APPLICANT: CITY OF COPPELL PLANNING DEPARTMENT Along the south side of Natches Trace Drive; approximately 250' east of Denton Tap Road. Approximately 1.65 acres of property. C (Commercial). Preliminary Plat and Site Plan approval for 150 student school. Owner: J. C. Jammal 854 Pelican Lane Coppell, Tx. 75019 (972) 462 -8206 Fax: (972) 393 -5966 Engineer: Jones and Boyd, Inc. Chuck McKinney 16100 Dallas Pkwy., Ste.240 (972) 248 -7676 Fax: (972) 248 -1414 HISTORY: There has been no recent development history on the subject tract, although a new middle and a new elementary school have been constructed within the last year on the parcel immediately to the east. TRANSPORTATION: Denton Tap Road is a PD6, six lane divided thoroughfare contained within a 100 -110 foot right of way currently under construction, with a completion date projected for the summer of 1999. SURROUNDING LAND USE & ZONING: North- vacant; "C", Commercial South - vacant; "C ", Commercial East - Denton Creek Middle School; SF -7 West - Denton Tap Road, vacant land; PD 133 for SF development Item # 13 f COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for regional retail DISCUSSION: The Master Plan supports retail activities for this property, and the proposed day care facility is a retail type use. Staff's primary concern with the application relates to access and the facility's appearance from Denton Tap Road, a Primary Image zone. The access is accommodated by Natches Trace Drive, which means the potential for traffic congestion along Denton Tap is minimized. The rear of the facility--that part of the building which faces Denton Tap --is a bit more problematic, but with proper landscaping, and with some idea of what the fifty foot strip between this center and Denton Tap Road is projected to be used for, this project could be a positive addition to the City of Coppell. We suggest more tree plantings along the Denton Tap exposure to the school would address our concern. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: The planning staff recommends approval of the request subject to several conditions which have not yet been met by the applicant. Specifically: - change road identification to reflect Natches Trace Drive on all exhibits -plant material screening parking areas needs to be 30" tall, not 24" as shown on the landscaping plan - provide a notation on all drawings that additional electrical wiring shall be underground and that mechanical equipment, electrical equipment and utility meters shall be either placed in inconspicuous locations or screened from view - preliminary plat signature blocks modified (TU /. Lone Star, in particular) - Compliance with other departmental comments (Fire and Building Inspection) - address the Denton Tap screening concern ALTERNATIVES: 1) Recommend approval of the request 2) Recommend disapproval of the request ATTACHMENTS: 1) Preliminary Plat 2) Architect's Site Plan 3) Architect's Elevations 4) Engineering Site Plan 5) Landscape Plan 6) Preliminary Irrigation Plan 7) Departmental comments Item # 13 / /' /A ' f A TATI / , iirrtfl'f� i. F 1. Nal ches lk= is com xt street name. 2. Did not see a floor plan included in set; however, cooking areas will require proper facilities as well as grease inters for cwllecdon of grease solids. 3. *ezws DEVELOPMENT REVIEW -COMM WEE FIRE PREVEIW6N COMMENTS SMART START SCHOOL ADDITION P-7 11 C A ► ' i tv & I CONTACT: TRAVIS CRUMP, FIRS MARSHAL. (214) 304 -3SA3 1. Minimum inside radius on fire lanes is 30 feet. Minimum outside radius is 54 feet. 2. A fully automatic fire sprinkler system is required. 3. Additional fire hydrants may be required.