Sonic Addition-LR 940825 e~l~-- CO]' "LTING ~.NGT~EER~
T~QU'B ~ ~nvi ro~ntat Assess~n~s
~ Soils & Fou~ations
Construction Hate~ia[s Testing
"Excellence by Ex.tie.e" C~rcia[ & l~ustria[ lns~ction
PO Box 92548 · South[ake, Texas 76092 · (817) ~29-0281
CONCRETE CYLINDER TEST RESULTS
PROJECT: The Sonic Addition LOCATION: Coppell
JOB #: 94-1171 DATE OF BREAK: 08-25-94 DAY: Thursday
CLIENT: Legend Construction CONTRACTOR: Legend Construction
CYL. SLUMP DATE OF DAYS
I.D. LOCATION (IN.) SAMPLE AGED POUNDS PSI
3 A unknown* 08-16-94 9 90,500 3201
3 B unknown* 08-16-94 9 88,500 3130
SPECIFICATIONS: 3000 psi @ 28 days
SUPPLIER:
REMARKS: Cylinders were made by contractor; contractor did not
provide location data. Contractor notified our lab
to pick up cylinders on 08-25-94.
Patrick Corbett
Technician
Q~O-- COY-'LTING ENGINEERS
T~F~QU~, _nvJronmentat Assessments
~I~. Soits & Fou~ations
Construction Ha~erJa[s Testing
"ExceLlence by Ex~rJence" C~rcia[ & l~ustria[ Ins~ctJon
PO Box 925~8 · Southlake, Texas 76092 * (817) 329-0281
DAILY CONSTRUCTION REPORT
PROJECT: The Sonic Addition LOCATION: Coppell
JOB #: 94-1171 DATE: 08-25-94 DAY: Thursday TIME: llam-lpm
CLIENT: Legend Construction CONTRACTOR: Legend Construction
ACTIVITIES:
WEATHER: Clear & Hot LOW TEMP: 75F HIGH TEMP: 95F
Travelled to job site, as requested, to pick up four (4)
concrete test cylinders made on 08-16-94 by contractor.
Also delivered twelve (12) cylinder molds to contractor.
Returned to office.
Lou Hargis, P.E.
President