Sonic Addition-LR 940810~I~QV~t ,viro~.enta[ Assessments ~. Soils & Foundations Construction Materiats Testing "Excettence by Experience" Conmercia[ & Industrial Inspection PO Box 92548 · Southtake. Texas 76092 · (817) 329-0281 FIELD COMPACTION REPORT PROJECT: The Sonic Addition LOCATION: Coppell JOB #: 94-1171 DATE: 08-10-94 DAY: Wednesday TIME: ll:00am CLIENT: Legend Construction CONTRACTOR: Legend Construction WATER DRY PER- TEST PROCTOR CONT. DEN CENT NO. LOCATION AND LIFT NUMBER (%) (PCF) COMP Northside Right-of-Way: 1. Left Pt @ Station 2+00 FG 2 12.1 97.4 97.2 2. Center Pt @ Station 1+50 FG 2 13.6 97.1 96.9 3. Right Pt @ Station 0+50 FG 2 14.1 96.5 96.3 REMARKS: Ail tests passed. Minimum Compaction Required: 95% FG = Final Grade Minimum of 4 tests per trip Also delivered four (4) concrete test cylinder molds to contractor. PROCTORS: 2. Tan & Light Gray Fine Sand w/ Clay 100.2 PCF @ 12.0% MOISTURE Patrick Corbett Technician