MA FY 97/98-LR 981001 Maxim Technologies Inc.
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telepho,~e: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CLIENT: ABCON CONSTRUCTTON
Attn: Rusty Whitaker PAGE 1 OF !
1045 E. HWY 121
Lewisville, TX 75057 PROJECT NO.: 9710310
REPORT NO.: 140204
PROJECT: Pavement Renovation -Coppell DATE OF SERVICE: 9/03/98
Texas, Various AUTHORIZATION: Rusty
719 HAWK REPORT DATE: 10/01/98
SERVICES: Sample concrete at location of placement, perform required field tests,
prepare and test concrete compress)re strength specimens.
PROJECT DATA
CONTRACTOR: A~CON CONTRUCTION CLASS OF CONCRETE: Mix #8203
CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 9/03/98
PLANT: #31 TIME SAMPLED: 12: 30PM BY: CME Division
SPECIFICATION REQUIREMENTS TEMPERATURE (DegF) - AIR: 99 CONCRETE: 93
STRENGTH: 3000psi @ 28 DAYS TRUCK NO: 738 TICKET NO: 1133150
SLUMP: 4" AIR: 3-6 MEASURED SLUMP (in.): 4 . 00
METHOD OF TEST AIR CONTENT(%): 5.30 UNIT WEIGHT(pcf): N/A
SAMPLING: ASTM C- 172 LOCATION OF PLACEMENT:
MOLDING & CURING: ASTM C31
SLUMP: ASTM C143 20x13 Concrete section street paving
TEMPERATURE: ASTM C1064 positioned dead center of side walk from
AIR CONTENT: 718 Hawk Road, right section of right (con'd)
UNIT WEIGHT: N/A
CAPPING/PADS: ASTM C617
TESTING: ASTM C39 REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH
SET NO. TESTED (days) (in.) (sq.in.} (Ibs. force) (psi) FRACTURE TYPE REMARKS
1 1 9/10/98 7 6.00 28.27 70!70 2480 UNBONDED CAP
1 2 10/01/98 28 6.00 28.27 99780 3530 LTNBON'DED CAP
1 3 10/01/98 28 6.00 28.27 99490 3520 UNBONDED CAP
ADDITIONAL COMMENTS:
LOCATION OF PLACEMENT: section of street looking west.
Technician: CME Division
Report Distribution:
III A~CON CONSTAUCT,ON MAXI TECH IE
(1) City of Coppell hsesall MAXI TE~
are addres
Our letters and reports are for the exclusive use of the client to whom theynot be reproduced except in
full without the approval of the testing laboratory. The use of our name must receive our written ap royal. Our letters and reports
1001 OY apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparent~ identical or similar products.