MA FY 97/98-LR 980806 Maxim Technologies Inc. 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: ABCON CONSTRUCTION Attn: Rusty Whitaker PAGE 1 OF 1 1045 E. HWY 121 Lewisville, TX 75057 PROJECT NO.: 9710310 REPORT NO.: 135957 PROJECT: Pavement Renovation -Coppell DATE OF SERVICE: 7/09/98 Texas, Various AUTHORIZATION: Rusty ROYAL LANE & CREEKVIEW REPORT DATE: 8/06/98 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressire strength specimens. PROJECT DATA CONTRACTOR: ABCON CONTRUCTION CLASS OF CONCRETE: Mix #CC 4050A CONCRETE SUPPLIER: Custom Crete Inc. DATE OF PLACEMENT: 7/09/98 PtANT: Dallas TIME SAMPLED: N/A BY: Luis Rivera SPECIFICATION REQUIREMENTS TEMPERATURE (DegF) - AIR: 90 CONCRETE: 96 STRENGTH: 3000psi ® 28 DAYS TRUCK NO: 355 TICKET NO: 147308 SLUMP: 5.0" Max. AIR: 4-6 MEASUREDSLUMP(in.): 3.75 METHOD OF TEST AIR CONTENT(%): 3.50 UNIT WEIGHT(pcf): N/A SAMPLING: ASTM C-172 LOCATION OF PLACEMENT: MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 Slab on grade, Royal and Crestview 5'south of TEMPERATURE: ASTM C1064 corner by 3'west of slab. AIR CONTENT: ASTM C231 UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. TESTED (days) {in.) (sq.in.) (Ibs. force) (psi) FRACTURE TYPE REMARKS 1 1 7/16/98 7 6.00 28.27 96900 3430 LTN'BONDED CAP t 2 8/06/98 28 6.00 28.27 131550 4650 UNBONDED CAP 1 3 8/06/98 28 6.00 28.27 132560 4690 UNBONDED CAP 1 4 HOLD Technician: Luis Rivera Started: 07: 00AM Stopped: 09: 00AM Report Distribution: _~ (1) ABCON CONSTRUCTION I , (1) City of Coppell Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced excel3t in full without the approval of the testing laboratory. The use of our name must receive our written ap royal, Our letters and reports 1001 DY apply only 1o the sample tested and/or inspected, and are not indicative of the quantities of apparent~ identical or similar products,