St Ann Catholic-LR010123CONCRETE COMPRESSIVE S" 5. NGTH TEST ,d,~,-,~,~/~r.,-,=,
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: January 23, 2001
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard Coppell, Texas
Coppetl TX 75019 Service Date: December 15, 2000
Project Number: 94001152
Report Number: 0032614
Material Information Sample Information
Specified Strength: 4000 psi @ 28 Days Sample Time: 9:55am
Technician: Ervin Farris
Batch Time: 9:14am Weather Conditions: Cloudy
Supplier: TXI Plant: 41 Accumulative Yards: 10
Truck No: 644 Ticket No: 2795004 Placement Method:
Mix I.D. No.: 8205 Sample Locations: Area above first lift
Placement Location: Switch-back ramp east of A-1 line to
courtyard
Field Test Data
Test Result Specification
Slump, inches: 6.50 5.0" Max
Air Content, %: 3.8 3-6%
Concrete Temperature,o F: 63
Ambient Temperature, o F: 44
Plastic Unit Weight, pcf: N/A
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Date Test Load Strength
No. ID (inches) Tested (days) (lbs) (psi)
1 I 6.00 12/22/2000 7 99,010 3,500
1 2 6.00 12/22/2000 7 96,680 3,420
Average 3,460
I 3 6.00 01/12/2001 28 117,810 4,170
I 4 6.00 01/12/2001 28 124,540 4,400
Average 4,290
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Ervin Farris Started: 8:30am Finished: 12:00pm ~__ ..~.,,,~/~__
(1) St. Ann's Ca~olic Community (1) Datum Engineering, Inc. Reviewed by: ~~~,//
(1) Centex Construction (1) City of Coppell
(1) City of Coppell v "'E-'~c 4- Cleveland, P.E.
(1) Alliance Architects Senior Project Engineer
The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above
and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual
samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Page I of 1 =,-~w,~,.F~,,.. ~