Loading...
St Ann Catholic-LR010123CONCRETE COMPRESSIVE S" 5. NGTH TEST ,d,~,-,~,~/~r.,-,=, 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: January 23, 2001 Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church Attn: Monsignor Kilian Broderick 180 Samuel Boulevard 180 Samuel Boulevard Coppell, Texas Coppetl TX 75019 Service Date: December 15, 2000 Project Number: 94001152 Report Number: 0032614 Material Information Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 9:55am Technician: Ervin Farris Batch Time: 9:14am Weather Conditions: Cloudy Supplier: TXI Plant: 41 Accumulative Yards: 10 Truck No: 644 Ticket No: 2795004 Placement Method: Mix I.D. No.: 8205 Sample Locations: Area above first lift Placement Location: Switch-back ramp east of A-1 line to courtyard Field Test Data Test Result Specification Slump, inches: 6.50 5.0" Max Air Content, %: 3.8 3-6% Concrete Temperature,o F: 63 Ambient Temperature, o F: 44 Plastic Unit Weight, pcf: N/A Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 I 6.00 12/22/2000 7 99,010 3,500 1 2 6.00 12/22/2000 7 96,680 3,420 Average 3,460 I 3 6.00 01/12/2001 28 117,810 4,170 I 4 6.00 01/12/2001 28 124,540 4,400 Average 4,290 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Ervin Farris Started: 8:30am Finished: 12:00pm ~__ ..~.,,,~/~__ (1) St. Ann's Ca~olic Community (1) Datum Engineering, Inc. Reviewed by: ~~~,// (1) Centex Construction (1) City of Coppell (1) City of Coppell v "'E-'~c 4- Cleveland, P.E. (1) Alliance Architects Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 1 =,-~w,~,.F~,,.. ~