St Ann Catholic-LR000808CONCRETE COMPR._.$SIVE STRENGTH TE . £
a divLvion ofl~rracm
8901 Carpenter Frwy., Suite #10{
Dallas, Texas 7524'
Date of Service: 07/31/2000 Report No.: 0019843 Report
Date
08/08/2000
Client No.: 2310 Project No.: 94001152
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard
Coppell TX 75019 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTRACTOR: Centex Construction MIX I.D.: 9506
CONCRETE SUPPLIER: TXI PLACE.MENT DATE: 07/31/2000 BATCH TIME: 8:5 lam
PLANT: 41 TIME SAMPLED: 9:45am BY: Ervin Farris
SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear
STRENGTH: 3000 psi @ 28 Days TEMPERATURE(F)- AIR 86 F CONCRETE: 83 F
SLL~fP: 5-7" TRUCK NO: 714 TICKET NO: 2686256
AIR: N/A AIR CON~YENT (%): N/A UNIT WEIGHT (per): N/A
TEST METIIOD: ASTM C- 143 PLACEMENT LOCATION:
Pier information and technician time: See Report 00019842
ASTM C- 172
ASTM C-39
SAMPLE LOCATION: K-8.5
REPORT OF TESTS ACCL3IULATIVE YARDS: 10
CYLINDER MEASURED I~-La-XIMUM COMPRESSIVE
bLa. RKED SLUMP DATE AGE LOAD STRENGTIt FRACTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
1 I 6.25 08/07/2000 7 95990 3390
1 2 6.25 08/07/2000 7 99150 3510
Average 3450
1 3 6.25 08/28/2000 28
I 4 6.25 08/28/2000 28
Technician: Ervin Farris Started: Finished: P'~
Report Distribution: E ' '
(I) St. Ann's Catholic Community (1) Datum Engineering. Inc.
(I) Centex Construction (1) CiD, of Coppell Eric J. Cleveland, P.E.
(I) City of Coppell Senior Project Engineer
(I) Alliance Architects
This report is exclusively for Ihe use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering. Inc.
01LL Page 1 of 1
CONCRETE COMPR._,$SIVE STRENGTH TEo £
a division
8901 Carpenter Frwy., Suite #10f
Dallas, Texas 75245
Date of Service: 07/31/2000 Report No.: 0019845 Report Date
08/08/2000
Client No.: 2310 Project No.: 94001152
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard
Coppell TX 75019 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTIL~,CTOR: Centex Construction MIX I.D.: N/A
CONCRETE SUPPLIER: TXI PLACEMENT DATE: 07/31/2000 BATCH TIME: N/A
PLANT: 38 TIME SAMPLED: 4:15pm BY: Shane Spinks
SPECIFICATION REQUIREMENTS WEATItER CONDITIO.N'S: Sunny, warm
STRENGTH: 3000 psi @ 28 Days TEMPERATURE(F)- AIR 98 F COXCRET~: 97 F
SLUMP: 3-5" TRUCK NO: N/A TICKET NO: N/A
AIR: N/A AIR CONTENT (c~): 2.2 UNIT WEIGIIT (pcf): N/A
TEST METHOD: ASTM C-143 PLACEMENT LOCATION:
Pier information and lechnician time: See Report gOO 19844
ASTM C-172
ASTM C-39
SAMPLE LOCATION: O-4.2, 0-4.4, 0-4.5
REPORT OF TESTS ACCm-WLATIVE YAm S: 10
CYLINDER MEASURED MAXLMUM COMPRESSIVE
3LARKED SLUMP DATE AGE LOAD STRENGTII FIL4,CTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
I 1 4.75 08/07/2000 7 86920 3070
I 2 4.75 08/07/2000 7 88770 3140
Average 3110
I 3 4.75 08/28/2000 28
1 4 4.75 08/28/2000 28
Technician: Shane Spinks Started: Finished: IJ~ gine~~
Report Distribution: En ' .
(I) St. Ann's Catholic Community ( 1 ) Datum Engineering. Inc.
(I) Centex Construction (I) Ci~' of Coppell Eric J. Cleveland, P.E.
(I) City of Coppell Senior Project Engineer
( I ) Alliance Architects
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.
01LL Page 1 of 1
CONCRETE COMPRESSIVE STRENGTH TEb .'
ENGL\IEF, RhNG, INC.
a division
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
Date of Service: 07/28/2000 Report No.: 0019679 Report Date
08/08/2000
Client No.: 2310 Project No.: 94001152
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard
Coppell TX 75019 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTILACTOR: Centex Construction MIX I.D.: 9506
CONCRETE SUPPLIER: TXI PLACEMENT DATE: 07/28/2000 BATCH TIME: 8:58am
PLANT: 43 TIME SAMPLED: 9:40am BY: Ervin Farris
SPECIFICATION REQUIREMENTS WEAl'It]ER CONDITIONS: Clear
STRENGTII: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 91 F CONCRETE: 86 F
SLUMP: 5-7" TRUCK NO: 644 TICKET NO: 2694938
AIR: N/A AIR CONTENT (%): N/A UNIT WEIGItT (pcf): N/A
TEST METHOD: ASTM C-143 PLACEMENT LOCATION:
Pier information and technician time: Sec Report #0019678
ASTM C-172
ASTM C-39
SAMPLE LOCATION: B-4.7
REPORT OF TESTS ACCUMULATIVE YARDS: l0
CYLINDER MEASURED MAXLMUM COMPRESSIVE
I~L&RKED SLU.%IP DATE AGE LOAD STRENGTIt FILa. CTLIRE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
I I 6.50 08/04/2000 7 66380 2350
1 2 6.50 08/04/2000 7 78250 2770
Average 2560
I 3 6.50 08/25/2000 28
I 4 6.50 08/25/2000 28
Report Distribution: jlE'~~~pE C.
(1) St. Ann's Catholic Community ( 1 ) Datum Engineering. Inc.
(1) Centex Construction (1) CiLv of Coppell Eric
(I) City of Coppell Senior Project Engineer
(I) Alliance Architects
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.
01LL Page 1 of 1
CONCRETE COMPRL3SIVE STRENGTH TEL 2
a division of ~lrl
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
Date of Service: 07/28/2000 Report No.: 0019708 Report Date
08/08/2000
Client No.: 2310 Project No.: 94001152
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard
Coppell TX 75019 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTRACTOR: Centex Construction MIX I.D.: N/A
CONCRETE SUPPLIER: TXI PL.&CEMENT DATE: 07/28/2000 BATCIITIME: N/A
PLANT: N/A TI.MESAMPLED: 4:00pm l~V: Shane Spinks
SPECIFICATION REQUIREMENTS WEATHER CONOITIONS: Sunny, warm
STRENGTII: 3000 psi @ 28 Days TEMPERATURE (F)- AIR 95 F CONCRETE: 93 F
SLUMP: 3-5" TRUCK NO: N/A TICKET NO: N/A
AIR: N/A AIR CONTENT (%): 2. I UNIT WEIGI1T (pcf): N/A
TEST METHOD: ASTM C- 143 PLACEMENT LOCATION:
Piers
ASTM C-172
ASTM C-39
SAMPLE LOCATION: See below
REPORT OF TESTS ACCL.~,IULATIVE YARDS: 10
CYLINI)ER MEASURED MA XIMLBI COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTII FRACTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
1 1 4.25 08/04/2000 7 103340 3650
I 2 4.25 08/04/2000 7 102000 3610
Average 3630
1 3 4.25 08/25/2000 28
I 4 4.25 08/25/2000 28
Sample location: 0-3.1, 0-3.2, 0-3.4, 0-3.5, 0-3.6, 0-5.8, 0-3.9
Technician: ShaneSpinks Started: 3:00pm Finished: 5:00pm I-J~~n~
Report Distribution:
(1) St. Ann's Catholic Community (1) Datum Engineering, Inc.
( 1 ) Centex Construction ( 1 ) City of Coppell Eric'JT. Cleveland, P.E.
(1) City of Coppell Senior Project Engineer
( I ) Alliance ArchitecLs
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wrilten approval of HBC Engineering, Inc.
01LL Page 1 of 1
CONCRETE COMPRI.oSIVE STRENGTH TEL .'
ENGI.\~, l. bE.
a division of'l~m'mmn
8901 Carpenter Frwy., Suite #I00
Dallas, Texas 75247
Date of Service: 07/27/2000 Report No.: 0019598 Report Date
08/08/2000
Client No.: 2310 Project No.: 94001152
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard
Coppell TX 75019 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTRACTOR: Centex Construction MIX I.D.: N/A
CONCRETE SUPPLIER: TXI PLACEMENT DATE: 07/27/2000 BATCIITIME: 3:45pm
PLANT: 31 TIME SAMPLED: 4:30pm BY: Shane Spinks
SPECIFICATION REQUIREMENTS WEATIIER CONDITIONS: Sunny, cool
STRENGTIt: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 102 F CONCRETE: 98 F
SLUMP: 3-5" TRUCK NO: N/A TICKET NO: N/A
AIR: N/A AIR CONTENT (%): 1.9 UNIT WEIGIIT (pcf): N/A
TEST METIIOD: ASTM C-143 PLACEMENrF LOCATION:
Piers
ASTM C-172
ASTM C-39
SAMPLE LOCATION: 0.9-3.2, 0.9-3.4, 0.9-3.5.0.9-3.6
REPORT OF TESTS ACCUMULATIVE YARDS: 10
CYLINDER MEASURED ,~La. XIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FI~CTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
1 1 5.25 08/03/2000 7 90450 3200
1 2 5.25 08/03/2000 7 96360 3410
Average 3310
1 3 5.25 08/24/2000 28
I 4 5.25 08/24/2000 28
Technician: Shane Spinks Started: 4:00pm Finished: 6:30pm ~ ~n
Report Distribution: ~ C.
(I) St. Ann's Catholic Community (i) Datum Engineering. Inc.
(1) Centex Construction (I) City of Coppell Eric J. Cleveland, P.E.
( 1 ) City of Coppell Senior Project Engineer
(1) Alliance Architects
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.
0ILL Page 1 of 1
CONCRETE COMPRLJSIVE STRENGTH TEL/
ENGhN~_~R~NG, INC.
a division oflFarrm:~
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
Date of Service: 07/27/2000 Report No.: 0019572 Report Date
08/08/2000
Client No.: 2310 Project No.: 94001152
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard
Coppell TX 75019 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTRACTOR: Cer~tex Construction MIX I.D.: 9506
CONCRETE SUPPLIER: TXI PLACEMENT OATE: 07/27/2000 hATCH TIME: 9:02am
PLANT: 43 TIME SAMPLED: 9:40am ny: Ervin Fan-is
SPECIFICATION REQUIREMENTS WEATHER CO~'OITIONS: Cloudy
STRENGTH: 3000 psi @ 28 Days TEMPERATVRE(F)-AIR 88 F CONCRETE: 83 F
SLt~m: 5-7" TRUC~ NO: 837 TIC,rET NO: 2693683
AIR: N/A AIR CONTENT (%): N/A UNIT WEIGIIT (pct'): N/A
TEST METHOD: ASTM C-143 PLACEMENT LOCATION:
Pier information and technician time: See Report gOO 19521
ASTM C- 172
ASTM C-39
SAMPLE LOCATION: B-4.5
REPORT OF TESTS ACCUMULATIVE YARDS: 10
CYLINDER MEASURED ,MA XL~UL~-I COMPRESSIVE
MARKED SLUI~IP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
1 I 6.00 08/03/2000 7 78180 2760
I 2 6.00 08/03/2000 7 82040 2900
Average 2830
1 3 6.00 08/24/2000 28
1 4 6.00 08/24/2000 28
Technician: Ervin Farris Started: Finished: ~ ~
Report Distribution: E .
(1) st. Ann's Catholic Community (I) Datum Engineering, [nc.
( I ) Centex Construction ( I ) City of Coppcll Eric E'Cleveland, P.E.
(I) City of Coppell Senior Project Engineer
( I ) Alliance Architects
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering. Inc.
01LL Page 1 of I
CONCRETE COMPRE- SIVE STRENGTH TES.
a division
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
Date of Service: 07/10/2000 Report No.: 0017869 Report Date
08/08/2000
Client No.: 2310 Project No.: 94001152
Client: St. Ann's Catholic Community Project: St. Ann's Catholic Church
Attn: Monsignor Kilian Broderick 180 Samuel Boulevard
180 Samuel Boulevard
Coppell TX 75019 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTRACTOR: Centex Construction MIX I.D.: 9506
CONCRETE SUPPLIER: TXI PLACEMENT DATE: 07/10/2000 BATCH TIME: 12:30pm
PLAN"r: 41 m~m SAMPLED: 1:05pm BY: Ervin Farris
SPECIFICATION REQUIREMENTS WF~axTHER CONDITIONS: Clear
STRENOT)I: 3000 psi @ 28 Days TEMPEILs, TURE (F)- AIR 93 F CONCRETE: 89 F
SLUMP: 5-7" TRUCK NO: 368 TICKET NO: 2678643
AIR: N/A AIR coh~rE,'vr (%): N/A UNIT WEIGIlT (pcf): N/A
TEST METHOD: ASTM C-143 PLACEMEN"r LOCATION:
Piers
ASTM C-172
ASTM C-39 Technician Time: See Report ,gOO 17868
SAMPLE LOCATION: 16-C
REPORT OF TESTS ACCU31ULATIVE YARDS: 10
CYLINDER MEASURED MAXLML~-i COMPRESSIVE
~L.~RKED SLUbIP DATE AGE LOAD STRENGTH FIL&CTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
I 1 6.50 07/17/2000 7 84240 2980
I 2 6.50 07/17/2000 7 83270 2940
Average 2960
1 3 6.50 08/07/2000 28 122820 4340
I 4 6.50 08/07/2000 28 130670 4620
Average 4480
Technician:Report Distribution:Ervin Fan'is Started: Finished: IJ~ En~.
(I) St. Ann's Catholic Cormnunity ( 1 ) Datum Engineering, Inc.
(I) Centex Construction (1) City of Coppell Eric J. Cleveland, P.E.
(I) City of Coppell Senior Project Engineer
( 1 ) Alliance Architects
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.
0ILL Page I of I