Loading...
MA 96/97-LR 971008  Maxim Tech. · Southwestern Labs · 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 T E C H N O L O G I E S I N C Telephone: {214} 631-2700 FAX: (214) 920-1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: ABCON CONSTRUCTTON Attn: Rusty Whitaker PAGE I OF 1 1045 E. HWY 121 Lewisville, TX 75057 PROJECT NO.: 9710310 REPORT NO.: 124270 PROJECT: Pavement Renovation -Coppell DATE OF SERVICE: 9/30/97 Texas, Various AUTHORIZATION: Rusty Gateway and Freeport REPORT DATE: 10/08/97 SERVICES: sample concrete at location of placement, perform required field tests, prepare and test concrete compresslye strength specimens. PROJECT DATA CONTRACTOR: ABCON CONTRUCTION CLASS OF CONCRETE: Mix #8274 CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 9/30/97 PLANT: 31 TIME SAMPLED: 09: 40AM BY: Phillip L, Forrest SPECIFICATION REQUIREMENTS TEMPERATURE {DegF) - AIR: 79 CONCRETE: 94 STRENGTH: 5000psi @ 28 DAYS TRUCK NO: 560 TICKET NO: 895999 SLUMP: 5" AIR: 4-6 MEASURED SLUMP (in.): 5,50 METHOD OF TEST AIR CONTENT(%): 5 · 5 UNIT WEIGHT(pcf): N/A SAMPLING: ASTM C-172 LOCATION OF PLACEMENT: MOLDING &CURING: ASTM C31 Paving, west lane of gateway 100 block 3' SLUMP: ASTM C143 TEMPERATURE: ASTM C1064 south of north side 10'west of east side. AIR CONTENT: ASTM C231 UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. TESTED (days} (in.) {sq.in.} (Ibs. force}.. (psi} FRACTURE TYPE REMARKS 1 1 10/07/97 7 6.00 28.27 101320 3580 CONE 1 2 10/07/97 7 6.00 28 - 27 106220 3760 CONE 1 3 10/28/97 28 i 4 10/28/97 28 ADDITIONAL COMMENTS: 10 Gallons of water added at site. Technician: Phillip L. Forrest Started: 08:00AM Stopped: 10:00AM Technician Report Distribution: ll ) ABCON CONSTRUCTION nl city o, co.,~, ERN LABS . . Ch.E. Our letters end rap~ls we fro' the exclusive use of the diem to whom they we ad~r. ened end shall not be re educed exce in fuJI without the apixoval of the testing laborltoq,. The use of our name must recmve out written ap ovd, ~r~r lettin ~l~re~portl 1001 DY apply ordy to the sample tested and/~x inspected, end ate not indicative of ~e quantities of epparen~yidentlcd ot similar Weducte.