Loading...
Stoneleigh P1-CS 970530TheCity With A Beautiful Future P.O. Box 478 Coppell, Texas 75019 214-462-0022 May 30, 1997 Mike Daniel, P.E. Nathan Maier Consulting Engineers, Inc. Two North Park, Suite 600 8080 Park Lane Dallas, TX 75231 RE: Stoneleigh at Riverchase, Second Construction Plan Review Comments Dear Mr. Daniel: The City of Coppell has received and reviewed the referenced plans and has the following comments to offer: 1. Locate the sidewalk in the 5' sidewalk easement instead of on the back of curb. 2. On the deceleration lane detail, install white pavement markings at the location shown, use Type I white double reflective buttons at 30" o.c. instead of the 8" paint striping, install 1- OR3-5R 30"x40" sign at the location shown, and minimum transition length shall be 100'. 3. On the general notes on sheet 2, grading and erosion control plan, lime stabilization or 8" of C.T.B. are required for the subgrade in the right-of-way. 4. On the drainage area map, drainage area "A" needs to be picked up in a drainage system. This is too much drainage to discharge into Riverchase Drive. 5. On the water and sewer plan, upsize the 4" services to a 6" sewer service and construct manholes at connections to the 6" and 8" lines. Contact Matt Cast, Superintendent of Public Services, at (972)304-3551 with any questions. 6. On the general notes and details, the lane section will require lime stabilization or letter requesting a variance. There are various other minor comments throughout these plans. Once all comments have been addressed, the revised set of plans should be resubmitted to the City for review. If you should have any questions concerning these comments, please feel free to contact me at your convenience. Graduate Engineer