St Ann Catholic-CS 991001 03/13/00 M0N 16:45 FAX 972 235 9544 Pacheco Koch Consult Eng ~002 · The City With A Beautiful Future972-462-0022 ~ P.O. BOX 478 COPPELL, TEXAS 75019 October 1, 1999 James A. Koch, Jr., P.E., R.P.L.S. Pacheco Koch Consulting Engineers 9401 LBJ Freeway, Suite 300 Dallas, Texas 75243 RE: St. Ann Catholic Church Dear .Mr. Koch: The City of Coppell has received and reviewed the referenced plans and has the following comments to offer: 1. Provide an easement for the on-site public water line or it needs to be metered with the vaults located in the right-of-way or in an easement. 2. The proposed gates in the northeast portion of the property need to be approved by the Coppell Fire Department. 3. Provide ADA ramps at all sidewalk/driveway intersections. 4. All proposed paving will need to be on 6" lime-stabilized subgrade per the City of Coppell Subdivision Ordinance. ~'~' 5. Please show thc removal of pavement for the existing Sandy Lake Road driveway. 6. Please distinguish between the shading on the building and the proposed paving on the Paving Plan. 7. Ibc portion of the existing storm drain to be abandoned underneath the proposed building needs to be plugged and removed. 8. Confirm that the existing inlets proposed to carry the storm runoff are designed to handle the additional flow. 9. The proposed fire line and fire hydrant locations need to be approved by the Fire Department. 10. The minimum grade for a 12" sanitary sewer is 0.20%. 11. Provide a profile for the 12" sanitary sewer line. 12. On the alternate bid paving plan, the proposed circular drive needs to be adjusted to meet the 30' offset requirement relative to Sandy Lake Road. 13. For the alternate bid sanitary sewer line, a manhole will be required where the existing line is abandoned and the proposed line is started. There are various other minor comments throughout the plans. Once these comments have been addressed, these marked plans and two sets of revised plans should be resubmitted to the Ci~ for review. If you have any questions concerning these comments, contact me at (972) 304-7019. Sincerely, Kent M. Collins, P.E. Civil Engineer 03/13/00 .MON 16:46 FAX 972 235 9544 __ Pacheco Koch Consult Eng ~003 PACHECO KOCH Co )pell. Texas 75019 The City With A Beautiful Future 972,o i EIVED -~_~" P.O. BOX 478 'O~tober 2'~, 1999 Christopher M. Jones, P.E. Senior Project Manager Pacheco Koch Consulting Engineers 9401 LBJ Freeway, Suite 300 Dallas, Texas 75243 RE: St. Ann's Project Dear Mr. Jones: It was a pleasure to meet with you and Mr. Ramps in Monsignor Broderick's office on Tuesday. I have reviewed your concerns regarding the loop fire lines, as well as the check valves with our Fire and Engineering Departments. Let me'start with the fke loop line. The loop line is provided for in the Uniform Fire Code, as adopted by the City. Therefore: I am in no position to administratively waive this part of the Uniform Fire Code. The additional hydrant is also required under the City's Code. If you have any questions regarding this, please contact Travis Crump at (972) 304-3500, and Mr. ',,.~ Crump will review with you the City's position with regard to the Uniform Fire Code. With regard to the check valves, I discussed with City Engineer Ken Griffin, the check valve will be required for the new sprinkler system they will be connecting on Samuel. Also, a check valve will be required for the loop line that loops into the residential street to the north of the project. The two additional check valves, one on Samuel and one on Sandy Lake, can be avoided by transferring those lines to the City through private instrument. No replat will be necessary. The City will be available to assist you in that transfer if your client decides to do this. Therefore, out of the four check valves we discussed, only two will be required by the City, as well as the TNRCC. Once again, I have no administrative latitude in this area since the TNRCC requires under Texas law a check valve at any cross connection with public water supply. If you have-any questions regarding the check valve, please do not hesitate to contact Ken Griffin, our City Engineer, at (972) 304-3679. In closing, please feel free to contact any of our departments if you have further questions regarding this project. I ]ty Manager JW:kb cc: Clay Phillips Jay Turner ~'~ Monsignor Broderick Travis Crump Bob Kruse Greg Jones 03/13/00 MON 16:47 FAX 972 235 9544 Pacheco Koch Consult Eng ~005 Oct-27-gg 03:03P P.02 ~4-4 GENERAL i NFOI~MAT ION NFPA 24 (e) Beginning aL the inlet side of the check valve on a gravity or pressure tank. .... ' S~ndard for the Installation of ~11. [nd[cams a mandatory requiremenL Private Fire Se~ice Mains and S~ld. Indicates a recommendation or that which is Their Appurtenances advi~ bu~ not require, ~n~d. A d~ument, the ma~n tex~ of which contains 1995 Edition only mandato~ provisions using ~he wo~ "sh~" to indlca~e requi~ments, which is in a Form generally suitable for man- NOTECE: .M~ aslcrisk I*) 1Ollowil~g the at,tuber ~r letter da:o~ reference by anot~r standard or code or for adop~on des~gnagmg a paragraph h~dic:ates explana(o~ m~teri~ on i~o ~w. Nonman~tory provisi~s shall be [~ated in ~n that paragraph in Ap~ndix A. Ap~nd~x, ~mote, or fine-print no~e and are not to be con- [~tbrfil:Hi.ll oft r~F~.rcl~.c([ publications can be found in Chapter I't ,t,'(i .Xppe.(hx B. sider~ a part of the requiremen~ ora standa~. Chaplet I General [n[o~ation 1~.1 A b).out pqan shatl be approved by thc amhority having jurisdiction in every case where a new prix'arc fire i-1 Scope. This s:andard establishes the minimum service main is comemplaled. requirements [~r installation of pnva~e fire ~ice ~m !-4.~ The plan shall be drawn ~o scale and shall include and ~heir appurtenances supplying automatic sprinkler all es~ntial details such as: systems, open ~pr:nkler ~vstems, wager spray Rx~ systems, f~am sy~:em~, private hydrants, monitor nozz~s or stand- (a) Size and [~at~n of all wa~er supplies. pipe sw~em.~ wi~h reierc~ces ~o wa~er supplies, private (b) Size and Iocadon ofa~l piping, md~ting, where pos- hydrants, and ho~c houses. This standard also a~plies to sible, the class and type and depth of exis6ng pipe, the "~.mbincd s~rvicc main~" used ~o carry water for ~th fire clas~ and ty~ of new pipe to be instaUed, and the depth to service and -~he:' use Thc authorit~ having jurisdiction which i~ i~ lo ~ buri~. ~hall ah,-,*rs bc c:(m~u]tcd ~Rn'c ins~lla6on or rem~eling (c) Size. ty~, and location of valve. Indicate d' I~ated or'pre,ate ~rc ~cr~icc mai~s, in pit or if operation is b~ ~st indicator or key wrench through a cnrb ~x. Indicate the size, type. and location of !-2 Put,se. '['hc purp.se ofthi~ standard b to provide meters, regu~tors, and check valves. a reasonub~ degree oY protection [br life and pro~rW -onx tire thr~t~g~ instn:lation r~uirements Ibr private fire humored) Sizeuf outlctsand IocatiOnand if Ofottt]etshydrantS,are to showingbe equippedSiZe withand ('- .... ~c:-x-ic-e main s~s~cms based upon sound engin~ring pein- independent gaze valves. Indicate if hose houses and ciples, test dat,~, and field experience. Nothing in this senn- equipment are to be provided and by whom. dard is ~mend~d ~o restrict new techno~gies or alterna:et arrar:geme~xt~, pr,~ding thc level of safety pre~ribed by (e) Sprinkler and standpipe risers and monitor nozzles the ~t;t~l~iard i~ not lowered, to be supplied by the Wstem. (~ L~ation of 6re department connec~ons, ~f pa~ of pti- !-3 Definitions. rate fire service main zy~em, including d~ail o~onnccdons. Approv~.* Accup~;:blc [o (he auth(~ri~v having .jur[s- I-5 Inst~lafion Wor~. Ins[al]ation work shah be done by dk't~;m, o~ fully experienced and responsible persons. ~ Authority Havin~ Jurisdiction.* The organizati ottkr, or individual .c~pot:~iblc for approving equipment./ !-6 Units. Metric umts of measurement in this standard a~ installation. ,n' a pr-cc:lure. / are in accordance with the modernized metric ~y~tem known as thc Imernational Sysiem of Units (SI). Two units x Lisled.* Equipment or materiali inck~ded in a li~t pub- (liter and bar). outside of but recognized by SI, are eom- lished b~ an or~ni~m,.m accco~b[c to the au~horky having monly used in international fire proleclion, ~hese ur.i~s t]oIIk~T1led product that listed in Table 1-6 with conversion factors. m,ti,:,ti~s periodic ~:~pcctio~ ~ff pr~uction of listed equip- n~c~: or m3tcn.~,, ,nd whose lis6ng slates either tl~at the rqttip~cnr ~r ~na~cri;t', ~nccts appropriat~ ~tandards ~r ~ccn len~ec[ ,~cl [~tmcl stthable t0r nsc il~ a ~ified manner. Table Private Fire ~rvice Main.* Ptivat~ fire service main. - :~ useri in this s:;md.trd, i~ that pipe and its appurtenances Nme of Unit Unit Symbol Conversion FRIOI on private pro~rl}-: liter L I ~1 = 3.7~ L (4t Between a so~rcc o1' ;~atcr and the base of the riser liter ~r minute per J¢~r ~,':lt~r-b,tscd [}t'¢ pt-oeec:ion systems, square mete[ (D:min)tm~ I 8pm/ftc = (40.746 ~min)/m~ ¢ubic dcctmetcr dm-~ I gal = 3.785 dm~ ~[~ ~vtt~een a ~t~tlt';'~ o[' water and inlets to foam making Papal Pa ! psi = 6894 757 ~ ~stc~ls. bar bar i psi = 0.0689 bar (cl ~¢:w~t: a ~o~r~c of w;ncr and the base elbow of pti- bar bar i bar = l0~ Pa icl, L',ed a~ ;:;'e pttmp ~uc-don and discharge piping, f,r Mttnt Pn~tt¢e 1995 Edition 03/13/00 )iON 16:48 FAX 972 235 9544 Pacheco Koch Consult Eng ~006 Oct-27-gg 03:04P P.03 AWWA C 15 I, Dm:tale Iron Pipe, Centrtfugally Cast in Metal [ A-I-$ Aulhori~/HayingJutisdiction. The phrase "author- ....... Molds or Sand-Li.ed Mohls, .for Water or Other Liquids, 1991. ity havingjurisdicthm" is used in NFPA documents in a broad AWWA C200. Yte¢l W. ter P~pe 6 m. and l~rger, 199[. manner, since jurisdictions and approval agencies vary. as do ~ their resp,)n~bilities. ~rhere public' safe~v is primary. ~he AWWA ('203. Cmd-Tar Pmtecta'e Ct:alin~ and ~nin~ for authority having ]u~icfion may be a i~deral, state, local, or Ste~l H-7~t~r Pipeli.e~ Enamel nnd Tape -- Hot .4pptied. 1991. other regional department or individual such as a ~re chief; AWWA (;205, Cent, ne-Mortar Pr.terti~,e Lining a~ C~ing fire marshal: chief ora fire prevention bureau, la~r depa~- lot Sleel tg~tter Pep. 4 irt. tt.d l~ttge; -- Shop Applied, 1989. merit, or health decrement; building o~cial: electrical AWWA C206. SlaItd,trd fi)r b~eld Wetdmg of Steel W~r insp~tor; or tubers having statutoo' attthodty. For insurance Pip~. 1991. purposes, an insurance inspection department, rating bureau, or other insurance company rcprcscntative may be A~VWA C207. ~tandard /be Steel Pipe Flanges for Water- the attthortty having jurisdiction. In many ch'cunlsmnces, the ',,~rk~ .~e~.tc~ ~ .~t:es a tn. T]irottKb 144 m.. 19~6. property owner or his or her designated agent assumes the A~¥~VA C.21)~. Dtnte*t.~totsn /be Fabricated Steel [Fhter Pi~e role of the authority having jurisdiction; at ~overnment F~ttmgs. i 963. installations, the commanding officer or deparm~ent.~ official AWWA C300, R~i~qbrr~d Con~rete Pre.tsure P~pe, Steel Cyl- may ~ the authority having juri~iction, tnder Type.lb; Wale; ,t.d Othe. LiquifY, 1989. A-I-$ Liat~. The means ibr identif}ing listed equip- AWWA C5.,I Prestressea Confrere Pressure Pipe, Steel- merit may vary for each organization concerned with prod- Cvlmder Fype. for Watrr and Oth~' l.i~dd~, 1992. uc~ evaluation, some of which do not ~cognize ~uipmem AWWA C302. Read, reed Confrere Pressure Pipe, Non- a~ listed unless it is al~ labeled. The authority havingjuris- C)hnder ~pe, for IP$tter and Other LtquMs, [987. diction should utilize the system emplo~ by the hsting AWWA (;303. Reit(fi, reed Concrete Pressure Ptpe, Steel- 0rganiza6on m identi~v a listed product, Cylinder ~x~e. Pretrn.~ioned. jbr Water nnd Oth~ Liqui&~, 1987. AWWA C400, Standard for Asbestos-Cement DistenSion A-I~ Piping should be laid so that the system can Pipe, 4 in Y?n'mtgh 16 tn., ~' gg?~ter and Other Li~dds. [~. extended with a minimum o[' expense. Possib}e plant expansion should also be considered and the pipmg AWWA C40i, .~tanda~d Ptacbcefbr the SHe~tton of.4~.~ta~- ~nid so that it will not be covered by buildings. One or more Cemet~t ~Vltlelm P,p~. 199'3. framed plans of the complete system ~kepc corrected up to AWWA CliO0, Stand, trd fi~r the hastalbttion ~' D~td~ lr~ ~te) nh~uld h .... ~i,'-nusly posted far rea~' referengg. %~;.zter .~la~,b u~,d 17reit ,~p~urlemt,ces. 1993. ] ~WW ~ C'60o C~n,'nt *totter Linin o' W tee Pi e ~nes /gA'~'~'~ l~ad-end mains ~houkl be avoided, if possible, 't 'ant' ~r~r ~;'~'tat'e [1189 '~ ~ a p 4 V arranging for mains supplied from bnth direction -' . , ' ............... %When private fire service maes are cc smerted :o dead-end [~ ~% k ( ~u ~ t,,,attot~( n o q,0est0x Cement Pre~ ~ ~t e,~ " ' ' : ' " ~ g' ' ' "' ""t ' P ~public maes, each situation should he examined to deter- 199D.. , '. '~.'-,- ; ...' . .. . , .. . ~,mne' d .... tt ~s practical to request the water utility to loop ..... ., . , ' .... P-, ' · ~nains in order to obtain a m~ re reliable suppiy. Th,-ou.¢h ~ 2 ol., [~' W~m',- Dl~lrib~41~oa. 1989. AWWA MI I, ~t~el PtI,e -- .~ (;.tde]or Design nttd installs- A-2-2.5 Where connections are made [ram public waeer- !IOn. ~989. works sxs~ems. ~nch systems shot~ld be guarded against possible omtaminatkn~ as fi>l[ows I.sre .~[l-II~t illattt~ql 14, 10-1,5 ANSI Publication. Amel-ican National Standards Bar~flou Pre;.emion atul Cra; Conner/mn ln~timte 1430 Broad.ay. New York. NY 10018, Ca) For pek ate fire ~ervice mains wi0~ direc~ connections ANSi ~ 16, I, ~tandatd for Ca.~t-Iron Pipe Flattffe,. .. and fi'om public waterwt~rka mains only. or wtth h(~,a~er p~imps F/etngrd Fittmg, /be 25. 125. 250 ,,d 8~) lb. 1975. installed in the connections t?om the street mains; no tanks or re~rvoirs; no physical connection t?om ,,thee water sup- plies; no anti-freeze or other additives of any kind: and Appendix A Explanato~ Material with all drains di~<harging to mmt~sphere, dry well, or o~her sal~ outlets, no backfl}~ protection ~s recommended Thi, 4ppendtx ,,. ,.,~ u p(~rl ~'l the *,qutrement~ ,sf this .VFP.~ d~nment at the service connection. ,~a ~. '~te'l'idrtl [qr ;.~]:,,~tt[ttt,n~tt pt~r~.~¢i ~,f~(x' (}J) Fen pcivate fire service tltain~ widx direct conl~CtiOIl A-l-3 Approved. Thc National Fire Frotec6on .~ia- t?om the public water attpply main pln~ one or more O'the tst:n does not app:'ox'¢, inspect, or certilV any installations. (k)llowing: elevated storage tallksl fire pumps taking suction pr~wedures, equipment, or materiats: nor does it approve tkom a~}~eground covered reservoirs or tankg (all or evi[lUale tesung I.:bor~rories. In determining the accept- l~tciElies are filled or connec{ed to public ssa~er only, the abilit? of instail;~t~ans, pr{~m'es, equipment, or materi- water in the tanks to ~ maintained in a pt~able cond'itionL al~. the authoritx having im'isdiction may base acceptance an approxed double ch~k valve assembly is recommendS. <m compliance with ~FP.& or other appropriate standards. (c) For private fire serxice mains directlx supplied From in the absence of qttch slander'ds, said authority may public mains with an auxiliary water ~upply such as a pnnd require evidence of proper instatlation, procedure, or use. or river on or available to t~e premise~ and dedicated The authority haxi,}~ jurisdiction may al~ refer to the I~t- fire depav[ment use; or lot systems supplied fi-om public ingq or lahehng practices of an organization concerned mains and interconnected with auxiliary supplies, such as: with product evalua;ions that is in a pn~i~inn to determine pumps taking suction from reservoirs ex~sed to contami- {,mplia~ce w~th appropriate standards for the current nation or rivers and ponds; driven wells, mills, or other -"pr:>duct~on of hsted items, industrial water swtems; or for systems or portions of 1995 .03/13/00. . . M0N 16:50 FAX 972 235~ 9544 Pacheco Koch Consult Eng .--.. ~007 0c1:,-2.7-99 03:05P P.04 1-6.1 Ifa value for measurement as given in this standard ~-4' Tanks. When gravity, pressure, or suction tanks are ...... is followed by an equivalent value in other units, the Rrst to be used, the authority having juriscliction shall be con- stated is to be regarded as the requirement. A given equiv- suited. Tanks shall be installed in accordance wiilt NFPA alent vait;e might be approximate. 2~. Standard for {~der T~ far Pr~:'~le Fire Protechoa. 1-6.2 The conversion procedure for the S! units has been 2-5 Penst~ or Flumes, ~rm, or Lakes. Water supply to multiply thc quanuty by the conversion ~hctor and ~hen con~tions F~)m penst~, ltum~, rivers, lakes, or r~r- round the result to the appropriate numar of significant voi~ shall ~ ar~'aoged to avoid mud and sedimen[ and s~{ dig~ts. ~ provided with approved double removabte ~rcens or appro~d strainers ins~lled in an approv~ manner. 2-6' FAre ~pa~mem Connections. Chapter 2 Wa~ Supplies 2~.i A conn~tion through which thc public fire depart- 2-1 Nature of Su~iy. '~e choice of water suppiies shall ~ sent can pump x,'utcr into the sprinkler, standpipe, or made in c~ration wkh the autho~ty havingjuri~iction, other system Furnishing wa~er {~)r fire extinguishment can make a desirable auxiliary supply. Fur this purpose, one or 2-2 Public Water Systems. (Applicable also to private more fire department connections shall be provide. ~uppiy systems ) Exctptmn: Omi. vsio, o/fire d~tme~{t co,nections shoe ~ per- 2-2.1 One or more connections from a reliable public mitred ~ a~rot,edg, y theauthodty hat, mgyu~d~ction. water ~ys~em shah be accep~ble. The capadty of the sup- 2-6.2 Fire detriment connections shah be properly ply shall meet ~he needed fire flow as determined by the authorily having .jurisdiction. supported. / 2-6.3 There shall be no shutoff valve in lhe fire depart- 2-2.2 Adcqu~v of water supply sh~! ~ detrained by flow~ sent connection. /tcs[s or other rc~iablc means. Where flow tm~ are ma~, thcl ~Hnw in ~l}ons per minute (L~min) t~ether wkh the static[ 2-6.4 An approved straight,'ay check valve shall ~and rcskiual prcssurm shall be indicat~ on the plan. -- installed in each fire departmem connection, located / ~ near as practicable ,o the point where it join~ the system. 2-2.S' P~blic mains shall be of ample size, in no ca ~smaller than 6 in. (152 mtn). 2-6.5 The pipe belween the c~eck va{ve and the hose coupling shul{ be equipped with an approved auto- 2-2.4 ~o pressure regulating valve shall b~ u~d in the marie drip. arranged to di~har~ ~o a proper place. --- water supply e~cept by special ~rmission of the authority 2-&.6 Fir~ department connections shah be of;~n app~ved having jur~sdi~'don. Where meters are used they shall be of ~n approved t)~. ~ type. 2~.7 The fire depariment connection(s) shall have ~he 2-2.Se Where connections are made from public water- ~H internal threaded s~ivel ~tt{ng(s) hays6 the NH s~n- works sv~t~m~ it might ~ n~esla~' to ~uard agaln~t po~- dasd th~ad, al }cu~t one of which sh;~i} be thc 2,5-7.5 sibie con~amin;tciot~ ofthe public supply. The requirements standard thread, a~ ~ped~ed in ~FPA 1[~3, 5{a~dnr~ oS' :h~ public health nuthoritv having jurisdiction shall be FYr~ ff0.~ de:er~incd and foltowed. W~ere ~uipment is installed to guard ~g;finst possible contamination of the public water ~xc'epl~on: ~'here ~otr~[ fire de~r~ri.~ent r'o~t~lec~tt)~ ~u ~ cot~o~ system, such equipment and devices shah be listed for fire to NFP.4 i96~. 5la/~dard ]br F~re H~..,~ ('Jo,nectb,~. 1~ a~ho~O' protection ~e,'vtce.- hat,i~tg )u~t-~to~ .~htdl d~ge the conneclio, to be ~-2.6 Connect:ohs to public ~at~ systems ~I~1 becontroli~ 2-6.8 Fire clepar:ment connections ~hall be equipped by post mdkator valv~ of an appro~ tv~ and I~at~ nm with standard cap~. properly secured and ~rranged For I~ th~ 40 R (12-2 m) from the ~ildings'prmected. ra~y removal by fire departmenb. Exrepffo,' (f this cad, not be done. the ~st indicatar :,ah,es s~l 2-6.9 Fire department connections shall be on d~e stree: be plered where lhe~, :mll be mt~ddy acce~s$~e in c~e t(flrt and ~Jde of building~ and shall he located and arranged so that ,at hable to inj,~. ~'5ee S,'ction 3-~ for det~,l.~ ) Wh~e ~.~t indi- ho~e lines can be readily and con~'eniently attached to cetor :'att'e.~ ca,not rv~d~ be ~d. as in a ciO' ~oc~, u~td~- the inlets without interi~rcnce t?ont an) nearby object~ g~:,u,d :,ah,es ,hall con/bna to these provisions a,d th~ir l~ations including buildings, l~nces, po~ts, or other fire departmen~ and directmt~ pi' {ur, b~g to open .~hall ~ cleari~ ~rked. connections. 2.~* Pumps. A fire pump installation consisting of ~-6. tO Signs. pumF, driver, and ~uction supply, when ofadequate capac- l-6.10.1 Fire department connections shall be designated itv anti reliability and pro,fly located, makes a good sup- by a sign ha~ing r;tised letters at least I in. :~5.4 mm) p~y. An automatically controlled fire pump taking water si~e cast on a plate or fitting, reading for service desig- from a water main of adequate capacity or taking draft hated: i.e.. "AUTO SPKR," or "OPEN SPKR." or "STAND. under a head from a reliable storage of adequate capacity, PIPE," shall be permitted to he. under certain conditions. accep:ed by the authority having jurisdiction as a single I l-6.10.Z Where a fire department connection only sup- supply. Pumps ~all be in,tailed in accordance with NFPA { plies a portion of the buildit:g, a sign shall be attached 20. Sta~,dard ]br the In.~tallaaon of Ce,t~fugal F~re Pumps. indicating the p,,rcions o{' the building supplied.