MA 95/96-LR 960404 Maxim Tech, · Southwestern Labs
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
T E C H N O L O G I ! S I N C Telephone: (214} 631-2700
FAX: (214) 920-1891
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CLIENT: ABCON CONSTRUCTION
Attn: Rusty Whitaker
1045 E. HWY 121
Lewisrills, TX 75057 PROJFCT NO.: 0903506319
RFPORT NO.: 39214
P80aECT: Pavement Renovation -Coppell DATF O[ SFRWC[: 3/21/96
Texas, Various AUTHORIZATION:
REPORT DATE: 4/04/96
SERVICES: Sample concrete at location of placement, perform required field tests,
prepare and test concrete compressire strength specimens.
PROJECT DATA
CONTRACTOR: ARCON CONTRUCTION CLASS OF CONCRETE: Mix Number 8274
CONCRETE SUPPLIER: TXI DATE OF PLACEMENT: 3/21/96
PLANT: 41 TIME SAMPLED: 02: 00PM BY: Marvin Greene
SPECIFICATION REQUIREMENTS TEMPERATURE (°F) - AIR: 69 CONCRETE: 70
STRENGTH: Not Provided TRUCK NO: 453 TICKET NO: 558328
SLUMP: 5" max, AIR CONTENT(%): 5,5
AIR: 3-6% LOCATION OF PLACEMENT:
METHOD OFTEST: ASTM C-39 Street repair 10' 6" x 100 240 Planation
ASTM C-143 St. Coppoll
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH
SET NO. (inches) TESTED (days) (in.) (sq.in.) (Ibs. force) (psi) REMARKS
i 1 5.00 3/28/96 7 6.00 28.27 86240 3050
1 2 5.00 4/04/96 14 6.00 28.27 95360 3370
1 3 4/18/96 28
1 4 4/18/96 28
Technician: Marvin Greene Started: 01:00PM Stopped: 03:00PM
Technician
Report Distribution:
(1) ABCON CONSTRUCTION MAXIM TECH. eSOUTHWESTERN LABS
(1) City of CoppeLt ar~
F. Ki;g COo , P.E.
1001 LW
Our letters end reports ere for the exclusive use of the client to whom they are eddre~ed and shall not be re reduced except in
full without the approval of the te~ting laborstory. The use of ournerne rnuet receive our written approval. ~k~ letters ~nd re ort~
apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparently identical or lirniler pr~PJct~.