Loading...
Summit P1-LR 961023SINACOLA 6 SONS TEL:214-456-8564 Oct 25 96 13:$2 No.O09 P .02 CONCRETE BATCH DESIGN CLIENT: BRANCH PROPERTIES. INC. PROJECT: SUMMIT AT THE SPRINGS cc: Joe Sandra Root File No. 6029 City of COPPELL Dowdy. Anderson DATE: 10/23196 REQUIRED STRENGTH: REQUIRED SLUMP: AIR CONTENT: CONCRETE TEMP: WATER/CEMENT RATIO: 3000 Psi ~ 28 Days (5.0 sack mix) ~, . 3 +/- 1" , k 0.353 (baSed on total cementitious mti) ~ MATERIALS Cement Fly Ash Course Aggr. Fine Aggr. AEA WRA TYPE & SIZE Type I Class C 1-1/2"-il4 ~/4-0 Air Entrainment Agent Water Reducing Agent _S. SD Lbs. ACTUAI.~ATJT,~ (1 cu. yd.) (1 cu. yd.) Cement 376 376 Fly Ash 118 118 Course Aggr. 1800 1800 Fine Aggr. 1440 1440 Water (3.84 gal/sk) 168 168 AEA 5.5 oz 5.5 oz WRA 14.1 oz 14.1 oz NOTE: 5.26 Sacks of Total Cementitious Material 20 % Cement Replacement (~ 1.25 lbs of Flyash ._.Replac.!.n[~ 1.0 Ib~, of Cement Add 1/2 Sack of Cement if required for Hand Placement of Concrete JEI~R~COPPELIL.WK4