Stoneleigh P2-LR010404 ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Da//as, Texas 75229
972/620-8911-972/263-4937 (Metro) DALLY FIELDREPORT
FAX: 972/406-8023
TESTED FOR: SPRING VALLEY CONSTRUCTION DATE: 04/04/01
DALLAS, TEXAS
PROJECT: STONELEIGH @ RIVERCHASE OUR REPORT NO: 00652-180
COPPELL, TEXAS
TECHNICIAN: J.S.
WEATHER: CLEAR TEMPERATURE RANGE: 70 TO 80
THE ALPHA TECHNICIAN TRAVELED TO THE ABOVE REFERENCED PROJECT SITE AS REQUESTED TO OBTAIN
3 SETS OF 4 CLIENT MADE CYLINDERS.
PER THE ON SITE REPRESENTATIVE THE CYLINDERS WERE MOLDED FROM THE FOLLOWING LOCATIONS: SET #1: SLAB FOR BUILDING #22, NORTHWEST A3 UNIT AT PATIO
SET #2: SLAB FOR BUILDING #22, EAST BREEZEWAY AT STAIR LOCATION
SET #3: SLAB FOR BUILDING #22, SOUTHWEST A3 UNIT AT PATIO DOOR
THE CYLINDERS WERE RETURNED TO THE LABORATORY FOR PROCESSING.
LABORATORY COMPRESSION TEST RESULTS WILL FOLLOW ON A SEPARATE REPORT.
IAT THE COMPLETION OF THE SCHEDULED WORK, THE TECHNICIAN RETURNED TO THE DALLAS OFFICE.
CC:
LARRY DAVIS, CITY OF COPPELL
LANNY ALLISON, CITY OF COPPELL
JAN BERTRAND, CITY OF COPPELL
~bnsd/e ~r~ ( ~i,s taHnb~' J ':rde
;~Parl~t:Veasl
~A~ppPaHr~ntlyT?~e~forOUsri nJ~ rmesan~ite~ln;~Sults mus! receive our wn~en approval. Test results and reports apply only ,o the sarflp
Geotechnical Engineering 0 Construction Materials Testing 0 Environmental Engineering 0 Consulting
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911-972/263-4937 (Metro) DALLY FIELD REPORT
FAX: 972/406-8023
TESTED FOR: SPRING VALLEY CONSTRUCTION DATE: 04/04/01
DALLAS, TEXAS
PROJECT: STONELEIGH @ RIVERCHASE OUR REPORT NO: 00652-185
COPPELL, TEXAS
TECHNICIAN: J.S.
WEATHER: CLOUDY TEMPERATURE RANGE: 65 TO 78
ITHE ALPHA TECHNICIAN TRAVELED TO THE ABOVE REFERENCED PROJECT SITE AS REQUESTED TO OBTAIN
i3 SETS OF 4 CLIENT MADE CYLINDERS.
PER THE ON SITE REPRESENTATIVE THE CYLINDERS WERE MOLDED FROM THE FOLLOWING LOCATIONS: SET #1: PAVING F, PARKING NORTHWEST OF BUILDING #16
SET #2: PAVING F, SOUTH OF G1-C
SET #3: PAVING F, PARKING BETWEEN G1-C AND GI-B
THE CYLINDERS WERE RETURNED TO THE LABORATORY FOR PROCESSING.
LABORATORY COMPRESSION TEST RESULTS WILL FOLLOW ON A SEPARATE REPORT.
AT THE COMPLETION OF THE SCHEDULED WORK, THE TECHNICIAN RETURNED TO THE DALLAS OFFICE.
CC:
LARRY DAVIS, CITY OF COPPELL
LANNY ALLISON, CITY OF COPPELL
JAN BERTRAND, CITY OF COPPELL
Our test results and reports are for the exclusive use of the Cllerlt (and their designateo recel)~ents on ~le in our office) roduced distributed except vath express ap;~roval of
ALPHA_ The use of our name and test results must receive ob; wnffen approval Test results and reports apply only to the s~[mples tested and/or observe(l, and are '~ot inclicat~ve of *.he qualit,es of
a;)parently ~denlical or similar specimens.
Geotechnical Engineering 0 Construction Materials Testing 0 Environmental Engineering 0 Consulting
ALPHA TESTING, INC.
Concrete
Test
, om ,ress,on
Dallas, Texas 75229 - e"or*
(972) §20:8911
Tested For: SPRING VALLEY CONSTRUCTION Our Report No.: 00652-148
A'FI'N: KELLER WEBSTER Issue Date: 04/04/2001
10950 ALDER CIRCLE
DALLAS, TX 75238
Fax Number: (214) 340-9100
Project Desc: STONELEIGH @ RIVERCHASE
COPPELL, TEXAS
FIELD DA TA
Placement Location: SOUTHWEST APPROACH
Date Placed: 3/6/01 Plant Number: 6-3000
Time Placed: 12:35 PM Delivery Ticket No.: 6144079
Slump (ASTM C-143): 3 Made By:. ALPHA
Air Content: N/A
Air Temperature: N/A Cured Specification: ASTM C-31
Specimen Temperature: N/A
Date Received: 3/7/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: CONTRACTOR
Mix Data Submitted By: LATTIMORE
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
328 LAB C-617 3/13/01 7 12 N/A 6 28.27 103106 3640
329 LAB C-617 4/3/01 28 12 N/A 6 28.27 113119 4000
330 LAB C-617 4/3/01 28 12 N/A 6 28.27 124558 4400
331 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifier'_ti.o_ ns: .............. 28 ........... 300-0-i
Results to Date: PASS!
Notes: CLIENT MADE CYLINDERS
Respectfully Submitted By: ./~.?~//~ /'~ of Alpha Testing, ,nc.
/
Our test resulG and reports are for the exclusive u~e of the/Client (a~ their designated recepien~ on file In our office) and shall no[ be reproduced and/or di~u'ibuted except
with express approval of ALPHA. The use of our name and test results must receive our wrflzen approval. Test resul~ and reports apply only to file ~ample$ tested and/or
observed, and are not Indicative of r~e qualities of apparently identical or similar specimens.