Stoneleigh P2-LR010123 REPORT OF FIELD
COMPACTION TESTS
ALPHA TESTIN( , INC.
2209 Wisconsin St., Suite 100
Dollos, Texos 75229
972/620-8911 - 972/2634937 (Metro)
FAX: 972/406-8023
TESTED FOR SPRING VALLEY CONSTRUCTION DATE 01/23/01
DALLAS, TEXAS
PROJECT ;~11~.~ RIVERCHA~E ---" OUR REPORT NO. 00652-105
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO DATE DEPTH'~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
309 01/23/01 SG/FG 2 17.5 108.5 18.3 107 99 2-A
310 01123/01 SG/FG 2 17.5 108.5 17.9 108 99 2-A
311 01/23/01 SG/FG 2 17.5 108.5 17.5 108 100 2-A
TEST LOCATION:
309 PAVING - APPROACH FROM FAIRWAY DRIVE 60' SOUTH & 15' EAST OF SE CORNER OF BUILDING #1
310 PAVING - APPROACH FROM FAIRWAY DRIVE 40' NORTH & 15' WEST OF NW CORNER OF BUILDING #11
311 PAVING - APPROACH FROM FAIRWAY DRIVE 55' WEST & 40' SOUTH OF NW CORNER OF BUILDING #11
CC. LARRY DAVIS, CITY OF COPP! LANh f ALLISON OF COPPELL
JAN BERTRAND, CITY OF COl~ 'ELL
· FILL * A IN PLACE SPECIFICATIONS
2 NATURAL SUBGRADE B
3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT ~
~' CEMENT TREATED D. RETEST
Geotecl~nical Engineering ~? Construction Materials Testing /~ Environmental Engineering /,~.' Const~ltin~