Loading...
Taco Bell-CS 950323DRC DATE: CONTACT: COMMENT STATUS: DEVELOPMENT REVIEW COMMI EE ENGINEERING COMMENTS S-1095, Taco Bel~ zoning change from C (Commercial) to C-S.U.P. (Commercial, Special Use Permit), to allow a drive4kmugk restaurant located on the west side of Denton Tap Road, approximately 145' north of Sandy Lake Rd., at the re, est of Huitt-Zollars, Inc. March 23, 1995 & March 30, 1995 Ken Griffin, P.E., Assistant City Manager/~ Engineer (304-3679) INI~?AL ~PRELIMINARY ~ Zoning Exhibit: No Commems Site 1. Plan Comments: The plan shows a 5 foot proposed right-of-way dedication, however, that is inadequate to contain the deceleration lane and required sidewalks. Therefore, additional right-of-way should be dedicated. Site plan shows a proposed future driveway. That driveway should be constructed now to allow two points of ingress and egress to the site. Therefore, off-site easements will be required. Your curb return radiis should be reevaluated. the south side of the site as opposed to 15 foot. on the south side of the site should be shown. The minimum radius should be 20 foot on Also, the radius for the existing driveway The water line should be extended as an 8" water line not a 6" water line. You should loop the 8" water line into the existing water line south of the site. You are showing a stacking distance for over 10 vehicles for your drive through. Have you considered some type of by-pass lane to allow vehicles to leave the drive through lane if necessary instead of being trapped in the lane? 6. The dimensions of the proposed deceleration lane should be shown.