Loading...
Stoneleigh P2-LR001018 REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dollos. Texczs 70229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR SPRING VALLEY CONSTRUCTION DATE 10/18/00 DALLAS, TEXAS PROJECT STONELEIGH ~ RIVERCHASE OUR REPORT NO. 00652-22 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPT~,~ NUMBER MOISTURE DRY OENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 213 10/18/00 FG-2.0 2 17.5 108.5 21.0 107 99 1-A 214 10/18/00 FG-1.0 2 17.5 108.5 20.2 103 95 1-A 215 10/18~00 FG 2 17.5 108.5 19.3 107 99 1 -A 216 10/18/00 FG-2.0 2 17.5 108.5 20.4 106 98 1-A 217 10/18/00 FG-1.0 2 17.5 108.5 19.7 106 97 1 -A 218 10/18~00 FG 2 17.5 108.5 19.9 104 96 1-A 219 10/18/00 FG-0.5 2 17.5 108.5 19.8 105 97 1 -A TEST LOCATION: 213 8" WATER LINE 10' NORTH AND 15' EAST FROM THE NORTHWEST CORNER OF BUILDING PAD ~25 214 8" WATER LINE 10' NORTH AND 15' EAST FROM THE NORTHWEST CORNER OF BUILDING PAD #25 215 8" WATER LINE 10' NORTH AND 15' EAST FROM THE NORTHWEST CORNER OF BUILDING PAD ~25 216 8" WATER LINE 15' EAST AND 30' SOUTH FROM THE SOUTHEAST CORNER OF BUILDING PAD #14 217 8" WATER LINE 15' EAST AND 30' SOUTH FROM THE SOUTHEAST CORNER OF BUILDING PAD #14 218 8" WATER LINE 15' EAST AND 30' SOUTH FROM THE'SOUTHEAST CORNER OF BUILDING PAD #14 219 10' NORTH AND 10' WEST FROM THE SOUTHEAST CORNER OF BUILDING PAD #20 CC: LARRY DAVIS, CITY OF COPPELL - LANNY ALLISON, CITY OF COPPELL - I FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUI~GRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R 3 LIME STABILIZED C. PERCENT IN PtACE MOISTURE DOLES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST L'P~ Geotechnical Engineel~ng · Construction Materials Testing · Environmental Engineering · Cons REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite I00 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR SPRING VALLEY CONSTRUCTION DATE 10/18/00 DALLAS, TEXAS PROJECT STONELEIGH @ RIVERCHASE OUR REPORT NO. 00652-22A COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID O~MUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPT~'~,~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 220 10118~00 FG-1.0 2 17.5 108.5 21.1 104 96 1-A 221 10/18/00 FG-1.0 2 17.5 108.5 20.3 104 96 1-A 222 10/18/00 FG-2.0 2 17.5 108.5 20.1 105 97 1 -A 223 10/18/00 FG-1.4 2 17.5 108.5 21.2 104 96 1 -A 224 10/18~00 FG-0.8 2 17.5 108.5 20.3 107 99 1 -A 225 10/18~00 FG-0.4 2 17.5 108.5 21.2 107 99 1 -A 226 10/18/00 FG-1.0 2 17.5 108.5 20.0 109 100 1-A TEST LOCATION: 220 25' WEST AND 30' NORTH FROM THE SOUTHEAST CORNER OF BUILDING PAD #25 221 20' EAST AND 25' SOUTH FROM THE NORTHWEST CORNER OF BUILDING PAD #25 222 20' WEST AND 25' NORTH FROM THE SOUTHEAST CORNER OF BUILDING PAD ~23 223 30' WEST AND 15' NORTH FROM THE SOUTHEAST CORNER OF BUILDING PAD ~23 224 25' SOUTH AND 25' WEST FROM THE NORTHEAST CORNER OF BUILDING PAD ~Y23 225 20' SOUTH AND 20' EAST FROM THE NORTHWEST CORNER OF BUILDING PAD ~23 226 20' NORTH AND 25' WEST FROM THE SOUTHEAST CORNER OF BUILDING PAD ~24 CC: LARRY DAVIS, CITY OF COPPELL - LANNY ALLISON, CITY OF COPPELL - ,~ . JAN BERTRAN, D, CITY OF COPPELL F,.L A. ,. P~CE PE.C~, .O,STV.~ A.O PEROE.. CO.PA~,O. CO..LY W,~ SPEC,F,C~T,O.S //_//./.. / ....... 7 ..... Geotechnical Engineering · ConstrucSon Materials Testing · Environmental Engineering · Consu~ng REPORT OF FIELD COMPACTION TESTS ALPHA TESTIN( , INC. 220~ Wisconsin St., Suite I00 Do#os, Texos 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR SPRING VALLEY CONSTRUCTION DATE 10/18/00 DALLAS, TEXAS PROJECT STONELEIGH t~ RIVERCHASE OUR REPORT NO. 00652-22B COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH'~ NUMBER MOISTURE DRY D~NSlTY MOISTURE DRY D{ENSITY COMPACTION COMMENT* % PC, J: % PC:F 227 10/18/00 FG-0.5 2 17.5 108.5 18.5 108 99 1-A 228 10/18/00 FG-0.4 2 17.5 108.5 19.9 105 97 1 -A 229 10/18~00 FG-0.9 2 17.5 108.5 20.6 105 96 1 -A 230 10/18/00 FG-1.0 2 17.5 108.5 20.3 105 97 1 -A 231 10/18/00 FG-2.7 2 17.5 108.5 20.2 108 99 1-A 232 10/18~00 FG-2.0 2 17.5 108.5 19.3 110 101 1-A 233 10/18/00 FG-1.8 2 17.5 108.5 20.5 105 97 1-A TEST LOCATION: 227 15' SOUTH AND 35' WEST FROM THE NORTHEAST CORNER OF BUILDING PAD ~20 228 20' EAST AND 35' SOUTH FROM THE NORTHWEST CORNER OF BUILDING PAD #22 229 25' WEST AND 35' NORTH FROM THE SOUTHEAST CORNER OF BUILDING PAD ~22 230 30' WEST AND 25' SOUTH FROM THE NORTHEAST CORNER OF BUILDING PAD #23 231 25' WEST AND 30' NORTH FROM THE SOUTHEAST CORNER OF BUILDING PAD ~23 232 35' WEST AND 25' NORTH FROM THE SOUTHEAST CORNER OF BUILDING PAD #23 233 20' NORTH AND 30' EAST FROM THE SOUTHEAST CORNER OF BUILDING PAD ~r24 CC: LARRY DAVIS, CITY OF COPPELL LANNY ALLISON, CITY OF COPPELL ~ . , JAN BERTRAND, CITY OF COPPELL I FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D RETEST Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · ConsuTtingl