ST9801-CS 991211' I/AX 1214) 352-3201 /~ 9 TELEPHONE (214) 358~581
ED BELL CONSTRUCTION COMPANY
POST OFFICE BOX 540787 10605 HARRY HINES
DALLAS, TEXAS 75354-0787 DALLAS, TEXAS 75220
December 10, 1999
Mr. Kevin C. Young, E.I.T.
Freese and Nichols, Inc.
1341 W. Mockingbird Lane, Suite 230E
Dallas, Texas 75247
Coppell Road Reconstruction
SH 121 to Sandy Lake Road
Coppell Project #: ST 98-01
Dear Mr. Young:
Enclosed for your review and approval are pre-cast junction box shop drawings from American
Industrial Pre-cast Products, Inc. Our utility subcontractor has proposed utilizing these structures
to construct the TY A storm sewer manholes detailed in the plans.
Please inform our office of your decision regarding this proposal. If you have any questions
regarding this proposal, don't hesitate to contact our office.
Icerely,
l! ?e21 Constr~ :ion Company
Robert D. Weber
Project Engineer
XC:
Mr. Kent Collins, P.E., Engineering and Public Works, City of Coppell
255 Parkway Blvd., Coppell, Texas 75019-4409
AN EQUAL OPPORTUNITY EMPLOYER
OPENING SIZE OR CAST
IN RING & COVER AS
REQUIRED BY CUSTOMER
SLAB TOP
1.852//
t
x, /
BOllOM SECTION
7,084#
EXTENSIONS
1,340# PER/F'F.
· K.O. PER JOB
" REQUIREMENT
,m!.
1. CONCRETE: 4000 PSI
2. REINF.: GRADE 60
3. H-20 LOADING
4. MAX. PIPE SIZE 3,3" W/27"
R.C.P. IN ADJACENT WALL
5. EXTENSION SECTIONS AVAILABLE
'4'-O"x4'-O"x4-'-O"
STANDARD JUNCTION BOX
W/VARIABLE HEIGHTS
,American Industrial Pre-Cast Products, Inc.
P.O. BOX 394 ALVARADO, TEXAS 76009. MErRO: 817-477'5286
501 FAST BAXTER SEGUIN, TEXAS 78155 210-401-0555
REQUIRED BY CUSTOMER
SLAB TOP
1,185ff
4'-0" BOllOM SECTION
4,815#
EXTENSIONS
1,040 PER/FT.
K.O. PER
JOB REQUIREMENT
- / \ , ~=
I
\ /
1. CONCRETE: 4000 PSI
2. REINF.: GRADE 60
3. H-20 LOADING
4. MAX. PIPE SIZE ,:30" I.D.R.C.P.
5. EXTENSION SECTIONS AVAILABLE
Y-O"x3'-O"x3'-6"
STANDARD JUNCTION"~BOX
W/VARIABLE HEIGHTS
American Industrial Pre-Cast Products, Inc.
P.O. BOX 394 ALVARADO, TEXAS 76009, METRO: 817-477-5286
501 EAST BAXTER SEGUIN, TEXAS 78155 210-401:0555