Terrapin Station-CS 981124 DEVELOPMENT REVIEW COMMITTEE
ENGINEERING COMMENTS
ITEM: Terrapin Station, Preliminar~ Plat, to allow the development of 7 commercial!
lots on approximately 10.5 acres of property, located along the north side of
E. Belt Line Road, approximately 700' east of North Lake Drive, at the
request of Turner, Collie & Braden, Ina
DRC DATE: November 24, 1998 and December 3, 1998
CONTACT: Mike Martin, P.E., Assistant City Engineer (972-304-3679)
COMMENT STATUS: ,/PRELIMINAR Y ~rn r ,~ r r, ~T Tre r:r~
1. Show size of proposed storm drain pipe and curb inlet.
2. Provide erosion control at storm drain outlet.
3. Who will maintain the west side of the proposed street?
4. Show the street name for the proposed street on the plat.
5. The Fire Marshal may require the proposed water line to be looped to ensure adequate
pressure during fire flow.
6. If the sanitary sewer line can be located in the right-of-way outside the limits of paving then a
sanitary sewer easement is not required.
7. As per the City's Subdivision Ordinance, the minimum driveway spacing for a 30 mph
roadway is 90'. This could affect the location of driveways for the proposed lots. Also, the
location of the proposed drainage inlet could affect driveway locations.
8. An 8' wide brick paver band will be required for the proposed street at the intersection of
Belt Line Road as per the City's Streetscape Plan.
9. The existing water line in Belt Line Road is a 10' line not an 8" line.