Loading...
Town Center L2B1-LR 960209 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: North Texas Contracting, Inc. DATE: 9 February 1996 PROJECT: Wendy's Town Center, Coppell, TX SUPPLIER: Lattimore LOCATION OF POUR SET 1: Paving, Spine Rd. ~ Station 16 + 25, northbound lane LOCATION OF POUR SET 2: Paving, Spine Rd. @ Station 6 + 50, northbound lane SAMPLE DATA: SET 1 SET 2 MIX NO. 42 Truck No. 282 617 Cement Ticket No. 7018097 7018104 Flyash Time Batched 9:54am 11:15am Sand Time Sampled 10:25am 11:45am in. Concrete Temp. ~ASTM C1064) 67°F 66°F 1.0 in. Air Content [ASTM C231) 4.8% 4.9% Water Unit Weight (ASTM C1381 Admix //1 Admix //2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C3S) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day {ASTM C143) psi Strength 64 4.00 3 02/14/96 53,300 1890 65 4.00 7 02/16/96 66,900 2370 66 4.00 28 03/08/96 67 4.00 28 03/08/96 28-Day Average 4000 68 4.75 3 02/14~96 45,700 1620 69 4.75 7 02/16~96 55,000 1950 70 4.75 28 03/08/96 71 4.75 28 03/08/96 28-Day Average 4000 TECHNICIAN: MAC (9:30am-1:00pm) DISTRIBUTION: (2) North Texas Contracting, Inc. (1) City of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 CORRECTED REPORT Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: North Texas Contracting, Inc. DATE: 9 February 1996 PROJECT: Wendy's Town Center, Coppell, TX SUPPLIER: Lattimore LOCATION OF POUR SET 1: Paving, Spine Rd. @ Station 16 + 25, northbound lane LOCATION OF POUR SET 2: Paving, Spine Rd. @ Station 15+75, northbound lane SAMPLE DATA: SET 1 SET 2 MIX NO. 42 Truck No. 282 617 Cement Ticket No. 7018097 7018104 Flyash Time Batched 9:54am 11:15am Sand Time Sampled 10:25am 11:45am in. Concrete Temp. (ASTM C10641 67°F 66°F 1.0 in. Air Content (ASTM C231i 4.8% 4.9% Water Unit Weight {ASTM C1381 Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C391 (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day IASTM C143! psi Strength 64 4.00 3 02/14/96 53,300 1 890 65 4.00 7 02/16/96 66,900 2370 66 4.00 28 03/08/96 67 4.00 28 03/08/96 2.8-Day Average 4000 68 4.75 3 02/14/96 45,700 1620 69 4.75 7 02/16/96 55,000 1950 70 4.75 28 03/08/96 71 4.75 28 03/08/96 28-Day Average 4000 NOTE: Concrete cores were taken 2/28/96 from same locations as Set I and Set 2 shown above. TECHNICIAN: MAC (9:30am-l:00pm) ~ ~ DISTRIBUTION: (2) North Texas Contracting, Inc. (1) City of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 CORRECTED REPORT Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: North Texas Contracting, Inc. DATE: 9 February 1996 PROJECT: Wendy's Town Center, Coppell, TX SUPPLIER: Lattimore LOCATION OF POUR SET 1: Paving, Spine Rd. @ Station 16 + 25, northbound lane LOCATION OF POUR SET 2: Paving, Spine Rd. @ Station 15+75, northbound lane SAMPLE DATA: SET 1 SET 2 MIX NO. 42 Truck No. 282 617 Cement Ticket No. 7018097 7018104 Flyash Time Batched 9:54am 11:15am Sand Time Sampled 10:25am 11:45am in. Concrete Temp. (ASTM C10641 67°F 66°F 1.0 in. Air Content {ASTM C2311 4.8% 4.9% Water Unit Weight (ASTM C138! Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS {ASTM C39! (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C1431 psi Strength 64 4.00 3 02/14/96 53,300 1890 65 4.00 7 02/16~96 66,900 2370 66 4.00 28 03/08/96 88,600 3130 67 4.00 28 03/08/96 88,000 3110 28-Day Average 3120w 3600 68 4.75 3 02/14/96 45,700 1620 69 4.75 7 02/16/96 55,000 1950 70 4.75 28 03/08/96 76,600 2710 71 4.75 28 03/08/96 76,400 2700 28-Day Average 2710'* 3600 NOTE: Concrete cores were taken 2/28/96 from same locations as Set I and Set 2 shown above. *Cores taken from this area and tested 3/8/96 indicated 3690 psi. **Cores taken from this area and tested 3/8/96 indicated~ psi. ~) TECHNICIAN: MAC (9:30am-1:00pm) ~ ~ DISTRIBUTION: (2) North Texas Contracting, Inc. (1) City of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148