Loading...
Town Center L2B1-LR 960206 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: North Texas Contracting, Inc. DATE: 6 February 1996 PROJECT: Wendy's Town Center, Coppell, TX SUPPLIER: Lattimore LOCATION OF POUR SET 1: Paving, north/south drive, north half of eastbound lanes @ Station 1 +00 LOCATION OF POUR SET 2: Paving, north/south drive, north half of eastbound lanes @ Station 2 + 20 SAMPLE DATA: SET I SET 2 MIX NO. 42 Truck No. 614 456 Cement Ticket No. 6028423 3021559 Flyash Time Batched 2:20pm 4:16pm Sand Time Sampled 3:05pm 4:55pm in. Concrete Temp. (ASTM C1064! 64°F 61 °F 1.0 in. Air Content (ASTM C231) 4.0% 4.2.% Water Unit Weight (ASTM C138) Admix //1 Admix //2 AkA COMPRESSIVE STRENGTH TESTS IASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143! psi Strength 48 5.25 7 02/13/96 130,600 4620 49 5.25 7 02/13/96 129,500 4580 50 5.25 28 03/05/96 ;[60,400 5670 51 5.25 28 03/05/96 ~[57,500 5570 28-Day Average 5620 4000 52 3.75 7 02/13/96 158,900 5620 53 3.75 7 02/13/96 154,100 5450 54 3.75 28 03/05/96 ;[89,100 6690 55 3.75 28 03/05/96 193,900 6860 28-Day Average 6780 4000 TECHNICIAN: MAC {1:30pm-6:O0pm) DISTRIBUTION: (2) North Texas Contracting, Inc. (1) Ciw of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: North Texas Contracting, Inc. DATE: 6 February 1996 PROJECT: Wendy's Town Center, Coppell, TX SUPPLIER: Lattimore LOCATION OF POUR SET 1: Paving, north/south drive, north half of eastbound lanes @ Station 1 +00 LOCATION OF POUR SET 2: Paving, north/south drive, north half of eastbound lanes ~ Station 2 + 20 SAMPLE DATA: SET 1 SET 2 MIX NO. 42 Truck No. 614 456 Cement Ticket No. 6028423 3021559 Flyash Time Batched 2:20pm 4:16pm Sand Time Sampled 3:05pm 4:55pm in. Concrete Temp. [ASTM C1064) 64°F 61 °F 1.0 in. Air Content (ASTM C2311 4.0% 4.2% Water Unit Weight (ASTM C138) Admix # 1 Admix //2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 1 2 inch cylinder) Cylinder Slump Age Tbst Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day {ASTM Cl 43! psi Strength 48 5.25 7 02/13/96 130,600 4620 49 5.25 7 02/13/96 129,500 4580 50 5.25 28 03/05/96 51 5.25 28 03/05/96 28-Day Average 4000 52 3.75 7 02/13/96 158,900 5620 53 3.75 7 02113/96 154,100 5450 54 3.75 28 03/05/96 55 3.75 28 03/05/96 28-Day Average 4000 TECHNICIAN: MAC (1:30pm-6:00pm) DISTRIBUTION: (2) North Texas Contracting, Inc. (1) City of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148